| Sl. No. | Item Description |
| 1 | Surface excavation in soft/loose soil, n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting out, complete all asdirected. |
| 2 | Excavation in trenches n.exc. 1.5 m width and n.exc. 1.5 m in depth for foundation, laying of UG cable, pipe etcin soft/loose soil & getting out, complete all as directed. |
| 3 | Returning filling in, including spreading, levelling, watering & well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 4 | Removing excavated material (soil) n exc 50 m & depositing where directed at a level n exc 1.5 m, complete all asdirected. |
| 5 | M&L plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 6 | M&L Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6 mmean radius built in cement mortar 1:6complete all as specified and directed. |
| 7 | M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) mixed with WPC as per manufactures instruction with a coat of hot blown bitumen of Grade VG-10 @ 1.5 Kg/Sqm and blended with clean dry sand @ 0.05Cum/Sqm complete all as specified and directed.Note:- WPC shall be measured & paid separately |
| 8 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate for beams, cantilevers, roof beam , lintels over 1.5 m span, etc, complete all as specified and directed. |
| 9 | M&L RCCnominal mix using Type B1 1:1.5:3 (20 mm graded aggrgate for Chajjas, complete all as specified and directed. |
| 10 | M&L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, banding spirally for hooping columns, hookingend and binding with and includingmild steel wire not less than 0.90 mm dia (annealed) complete all as specified anddirected. |
| 11 | M&L mild steel TMT bar 5 mm dia and over upto and including 10mm dia in strrups as inincluding cutting, bending and binding with and including mild steel not less than 0.9 mm dia (annealed)complete all as specified anddirected. |
| 12 | M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc flat, rought finished surfaces of concerete complete all as specified and directed. |
| 13 | M&L Formwork to sides and soffits of Formwork to chullah hoods, chajjas, troughs and similar items including edges flat, rought finished surfaces of concerete complete all as specified and directed. |
| 14 | M&L for Rendering 15 mm thick on other thanfair faces of brick work or concrete surfaces in cement mortar 1:6 for finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 15 | M&L rendering 20mm thick with cement mortar 1:4on fair faces of brick workin two layers (10mm and 10mm) sperately mixed withand including water proofing compund in top layer as per manufacturers instruction and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 16 | M&L 75mmthick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 17 | M&L Hardcore of gauge n exc. 63 mm, Broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface,complete all as specified and directed. |
| 18 | M&L 75mm thick cement concrete (1:3:6) type C-2( using 40mm graded crushed stone aggregate) as in plinth protection laid in alternatebays (not exceeding 2 Sqm each)and finished even and smooth without using extra cement and providing jointsthroughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed. |
| 19 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 20 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heatmoulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail;Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cementas per specification & drawing as specified in SSR Part I, Section 8 complete all as specified and as directed. |
| 21 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed. |
| 22 | S&F 100 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. |
| 23 | S&F 75mm MS butt hinges medium weight, complete all as specified and directed. |
| 24 | Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 25 | Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in floors fixed to walls and ceilings or laid in floors, complete all as specified and as directed. |
| 26 | S&F 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210gms), complete in all as specified and as directed. |
| 27 | S&F 15mm bore Bib taps, fancy type, chromimum plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 28 | S&F 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete as specified and as directed. |
| 29 | S&F 15mm bore pillar taps, cast copper alloy with capston heads, chromium plated,fancy type, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed |
| 30 | S&F PVC connection 15mm size with PTMT nuts, 600mm long complete all as specified and as directed. |
| 31 | M&L preperation of new surfaces of walls and applying three coat of white wash, complete all as specified and as directed |
| 32 | M&L for preparation of new wall surface applying Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm complete all as specified and directed. |
| 33 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed. |
| 34 | S&F 110mm bore PVC (SWR) Vent Cowl complete all as specified and as directed. |
| 35 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/Ceilings complete all as specified and as directed. |
| 36 | S&F 600x450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed. |
| 37 | S&F Wall Hung Vitreous china premium/1st quality wash down water closet EWC white/ ivory/off white (including all necessary accessories like rag bolts/ gel gasket etc. with seat cover, hinges, dual flush cistern fittings and fixing acessories minimum size 610x350x710mm with P/S trap complete all as specified and as directed. |
| 38 | S&F 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 39 | M&L Non - skidcoloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) of size 300mm x 300mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 40 | M&L Glazed ceramic coloured tiles in vertical surfaces 300x 600x 7 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 41 | S&F Powder coated Anodised aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitionswith one or more rebates including joining cleat for fixing etc. complete all as specified and directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 42 | S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) window andventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m includingnecessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specifiedNote:-(i)Glass/wire guage/Particle board as required shall be measured and paid seperately under appropiate item (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 43 | S&F 4mm thick plain sheet glass,ordinary quality fixed with Aluminum frame work not exc 0.5 sqm in each pane complete all as specified and as directed. |
| 44 | M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and directed. |
| 45 | S&F 150mm dia High density polyethylene pipes (HDPE) of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 46 | M&L Concrete bed to drain pipes of 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested; in 1:3:6 type C2 (40mm graded aggregate) complete all as specified and directed. |
| 47 | S&F vitreous China wash basin, white, flat back, size 550x400mmincluding brackets cutting forand pinning in ends of brackets or erecting stand, and 32 mm bore Waste coupling of PTMT (half or full hreaded) .(Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 48 | M&L Granite (of any type) 18-20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 20 mm thick Screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 49 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 50 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 51 | S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm, Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longincluding 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Aluminium framework with screws all as specified complete complete all as specified and directed. |
| 52 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including necessary preperation of surfaces and applying one shop coatof red oxide, zinc chrome primer complete all as specified and as directed. |
| 53 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165, including necessary prepration of surface and applying a coat of red oxide zinc chrome primer, complete all as specified and as directed. |
| 54 | M&L preparation new iron and steel surfaces of any description, exc 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 55 | Surface dressing in soft loose soil n exc 15 cm deep and getting out, complete all asdirected. |
| 56 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 57 | M&L preparation of new wall surface applying Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specificationover new surface over 1 mm thick wall care putty,complete all as specified and directed. |
| 58 | M&L Premimum quality Vitrified coloured Ceramic tiles 8 to 9 mm thick (square/ rectangular) of size 600mm x 1200mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including 15 mm thick Screed bed or bedding layer of cement mortar 1:6,for laying floor finishes, complete all as specified and directed. |
| 59 | M&L Glazed ceramic coloured tiles in vertical surfaces 100x1200x8-9 mm thick set and jointed in neat cement slurry & pointed in white or colour cement to match including backing coat 10 mm thick in Cement Mortar 1:4, complete all as specified and directed. |
| 60 | S&F Powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specifiedNote:-(i)Glass/wire guage/Particle board as required shall be measured and paid seperately under appropiate item (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 61 | S&F 6mm thick plain sheet glass,ordinary quality fixed with Aluminum frame workexc 0.5 sqm in each pane complete all as specified and as directed. |
| 62 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with Aluminum frame work complete all as specified and as directed. |
| 63 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed. |
| 64 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 65 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate flush type regulators] concealed in walls, withwith back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 66 | All as per item No 65 here-in-above but One socket out let 5/6 amps point on the same board |
| 67 | All as per item No 65here-in-above but One socket out let 5/6 amps point on the independent board |
| 68 | M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing cappingmedium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0.7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitablyto accomadiate fittings] concealed in walls, withand including back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i)Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 69 | S&F Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 70 | S&F Modular Socket 6 Amps, 5 pin, 2 module, complete all as specified and directed. |
| 71 | S&F Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 72 | S&F Modular Socket 6 A/ 16 Amps, 6 pin combined 2, complete all as specified and directed. |
| 73 | S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed |
| 74 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 75 | S&F Modular fan regulator, step type, 120 watt, 2 module, complete all as specified and directed. |
| 76 | S&F LED bulb 10 watt5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified and directed. |
| 77 | S&FMCB, DP, C Series 32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 78 | S&F RCBO for earth leakage, overload and short ciruit protection Double pole 230 Volts, 30mA, suitable for 32 Amps complete all as specified and as directed. |
| 79 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 80 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 doubledoor, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection,complete including. blanking plates as required &flush to wall/other surface complete all as specified and as directed |
| 81 | S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 82 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 6500K complete all as specified and as directed. |
| 83 | S&F energy saving & environment friendly long life 20 Watt,(or nearest next higher wattage)CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete withintegrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 84 | S&F energy saving & environment friendly long life 35/36 Watt,(or nearest next higher wattage)CT ≥ 6500 K, LED building security light made up of pressure die-cast aluminium housing with acrylic cover as diffuser with IP 66 protection & impact resistance not less than IK-07 complete withintegrated type, with high efficiency electronic driver, surge suppressor of 5 KV or more & high brightness LEDs, luminaire efficacy > 110 lumens/Watt, power factor ≥ 0.90, operating range 140 to 270 V, 50 Hz complete including GI pipe bracket of adequate size as required (Light Grade) of length 1.2 mtrs bent to shape and fixed with 40mm x 5mm MS flat with necessary nuts, bolts, washers etc, painting with two coats of syntheic enamel paint over a coat of primer and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 85 | S&F, 600mm x 600mm ultra slim recessed mounted LED module with high brightness, de-glaring PP diffuser and PS LGP de-glaring sheet for glare free uniform light distribution suitable for grid ceiling LEDluminarie 40 Watt, (or next nearer higher watt) 6500Kwith diffuser to ensure glare free and even light distribution& integrated electronic driver,with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply,complete all as specified and as directed. |
| 86 | M&L sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. |
| 87 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 88 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 89 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 90 | M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 91 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means ofbolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab(1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completioncomplete all as specified and as directed. |
| 92 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers and connecting up with and including three core twisted flexible copper conductor cable of suitable size all as specified & as directed. |
| 93 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) capacity complete all as specified and as directed. |
| 94 | Supply, installation and testing of electric water heater, storagetype, BEE 5 star rated, 25 ltr capacity 230 volts AC, 50 Hz comprising of high wattage heating elementfor instant heating, extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non-ferrous pressure plate withincluding provisionPVC connecting pipes 15mm dia 60mm long with brass coupling (heavy duty) for Hot/Cold connection and necessary grouting bolts suitably flushed to wall or any other surface including electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable/flexible chord complete all as specified and as directed. |
| 95 | S&F AC socket with MCB, DP 25 Amps, starter switch and socket with plug Top and indicator complete all as specified and directed. |
| 96 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing cappingmedium grade with accessories (ISI marked) of suitable size with all fittings and accessories ISI marked and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE: (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 97 | S&F 32mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 98 | S&F 50mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. |
| 99 | S&F 32mm outer dia, PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 100 | S&F 50mm outer dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and as directed. |
| 101 | Making connection of PP-R distribution branch with PP-R main of 50 to 75 outer dia. by providing and fixing tee including cutting and making fusion joint etc.complete all as specified and as directed. |
| 102 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity, complete all as specified and as directed. |
| 103 | S&F Discharge copper pipe line heavy duty 5/8\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 104 | S&F Discharge copper pipe line heavy duty 3/8\" dia and flair nut from indoor unit to outdoor unit of Split AC 1.5/2 TR complete all as specified and as directed. |
| 105 | S&F Nitrile insulation for copper tubing of size 5/8\" dia dully wrapped complete all as specified and as directed. |
| 106 | S&F Nitrile insulation for copper tubing of size 3/8\" dia dully wrapped complete all as specified and as directed. |
| 107 | S&F 15mm dia. PVC pipe nylon imbraided flexible drain water pipe (as approved) for condenser water drain pipe fixed with clamps in wall complete all as specified and as directed. |
| 108 | S&F metallic stand/Bracket for fixing of oudoor unit of Split AC complete all as specified and as directed. |
| 109 | S&F PVC insulated, PVC round sheathed copper conductor (flexible) industrial cable FRLS 1100 Volts conforming to IS 694 of size 4Sqmm 4 Core, connecting electrical equipments with terminal lugs/clips as per site requirement complete all as specified and as directed. |
| 110 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Polewith necessary lugs complete all as specified and as directed. |
| 111 | S&F VTPN DB, 8 Way, double door,Metal door ,IP-43 IK 09, with and including MCCB200 Amps, 4 Pole (upto 200Amps)incomer, and MCB;s as Outgoing , 125Amps rated bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces includingcomplete all as specified and as direct. Note:- MCB\"s required as Outgoing shall be measured and pair seperately under appropiate items |
| 112 | S&F MCCB 4 Pole 125 Amps, thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KAcomplete all as specified and as direct. |
| 113 | S&F copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 90 Volts to 290 Volts with O/P voltage stabilization at 230 Volts with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 4.0 KVA including electric connection complete all as specified and as directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy