| 1 | Dismantling and taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 200 Amps complete all as specified and directed by Engineer-in-charge. |
| 2 | Supplying and fixing, installing, commissioning and testing HT 11KV, 3 phase system, outdoor type gang operated switch, air break type suitable for vertical mounting complete with necessary insulators and separators, set of drop out fuses (12 insulators) and operating handle of GI pipe 25 mm dia, medium grade rod of suitable length (mechanically operating arrangements), locking arrangement with lock and two keys complete of rating 200 Amp complete all as specified and directed by Engineer-in-charge. |
| 3 | M&L for repair of air break gang operated switch vertical / horizontal mounted including required accessories like moving contact assembly, fixed contact assembly, insulators, arching horn,roller bearing assembly, blade stopper, AL Jumper, counter balancing spring, Nuts & Bolts, clamp, GI pipe, handleand operating mechanism of any capacity complete all as specified and directed by Engr-in-Charge. |
| 4 | Dismantling insulators any type, any size from its original position and removing from site complete all as specified and directed by Engineer-in-charge. |
| 5 | S&F pin type composite/polymerbrown insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade fixed on poles/cross arms of upto 9 m long complete all as specified and directed by Engineer-in-charge. |
| 6 | S&F Disc type insulator, porcelain, vitreous 150 mm high and 150 mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11000 volts complete all as specified and directed by Engineer-in-charge. |
| 7 | S & F of Disc type insulator composite/polymer one galvanised MS spindle, two GI washers andone GI nut,for 11000 volts grade, complete all as specified and directed by Engineer-in-charge. |
| 8 | Material and labour for Scrapping rusted portion of steel pole and applying one coat of primer after that applying two coats of aluminium paintincluding channels existed on Two pole structure complete all as specified and directed by the Engr-in-Charge. |
| 9 | Material and labour forScrapping rusted portion of old surface of steel poleincluding channels and applying onr coat of primer after thatapplying two coats of aluminium paint including making five no. alternative yellow & black strips 30 cm height each (upto 1.50 metre height from top of PCC coping & numbering to the poles with synthetic enamel paint complete all as specified and directed by the Engr-in-Charge. |
| 10 | Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed HT cable 11000 volts grade with aluminium conductor cross sectional area 95 sqmm 3 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/through pipescomplete all as specified & directed by Engineer-in- charge.Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule. |
| 11 | S&F in repair end termination joint 11 KV Outdoor type, end termination heat shrinkable of size 95 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed and directed by Engineer-in-charge. |
| 12 | Dismantling and taking out the old stay assembly complete incl demolition of plain cement complete all as specified and directed by Engineer-in-charge. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed.(ii)Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account. |
| 13 | Material and Labour Stay assembly complete with accessories as shown in electrical plate No 1 incl GI Adjustable Stay Rod of 20 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, excavation in any strata and PCC 1:3:6 concrete all as specified and directed by Engineer-in-charge. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire. |
| 14 | S & F in replacement of lightning Arrestor Expulsion type Transmission Class 65 Kilo Amps 11000 V Grade including connecting complete all as specified and directed by Engineer-in-charge. |
| 15 | M&L for disconnectingHT & LT side cables of follwing indoor/outdoor transformer of capacity upto 200 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil and to be collected in barrel by opening the transformer cover ,lifting of core,cleaning of oil tank and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank,using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same and fixed on its existing location after repairs all as specified and directed by Engineer-in-charge.Note-(i) Rewiding of HT/LT coil any type/material,dehydration of transformer oil etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be measured and paid seperately and cost of fixing and connection of spare shall be deemed to included in the quoted rate of the above items. |
| 16 | M&L for taking out old unserviceable HT/LT coil removing insulation complete by brushing coil,cleaning the inner body complete making free from dist and dirt,all impurities, applying paper insulation(IS specified) of transformer complete of capacity upto 200 KVA complete all as specified and directed by Engineer-in-charge. |
| 17 | M&L for re-winding of HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 200 KVA complete all as specified and directed by Engineer-in-charge. |
| 18 | M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 200 KVA complete all as specified and directed by Engineer-in-charge. |
| 19 | Disconnection of Transformer from HT/LT side at site,dehydration and filtration of thetransformer oil with the helpofoilfiltration plant of any capacity of distribution transformer indoor/outdoor type 11/0.433 KV.Notes a) The unit of payment under this item shall be for the oil required for all process to entire completion of the job.b) New oil required for topping up before dehydration & filtration shall be measured and paid separately under relevant item.c) The dielectric strength of oil shall not be less than 45 KV when maintained a gap of 3mm for one minute all as specified and directed by Engineer-in-charge.d) All T & P required for dehydration shall be arranged by the contractor at his own. |
| 20 | Supply and filling new transformer oil for Top up of superior quality conforming to IS 335:93 complete all as specified and directed by Engineer-in-charge. Make : POWER OIL/SAVITA/CASTROLNote : (i)The dielectric strength of oil should not be less than 45 KV when maintaineda gap of 3mm for one minute complete all as specified and directed by Engineer-in-charge.(ii)Contractor shall bring the transformer oil in sealed container and after use of oil, container shall be property of contractor and nothing extra shall be admissible on this account.. |
| 21 | Supply and fixing in replacement ofoil drain valve cast copper alloy any dia suitable for upto 400 KVA transformer outdoor type 11KV / 433V of existing make complete all as specified and directed by Engineer-in-charge. |
| 22 | Supply and fixing as in replacement of LT bushing assembly complete with insulator,brass stud rod, nuts, washers, gasket etc as per matching to existing complete with accessories suitable for upto 400 KVA transformer indoor/outdoor 11KV / 433V complete all as specified and directed by Engineer-in-charge. |
| 23 | Supply and fixing as in replacement of HT bushing assembly complete with insulator,brass stud rod, nuts, washers, gasket etc as per matching to existing complete with accessories suitable for upto 400 KVA transformer indoor/outdoor 11KV / 433V complete all as specified and directed by Engineer-in-charge. |
| 24 | Supply and fixing in replacement of Silica breather assembly including silica gel weight 250gm filled complete set suitable for 63 KVA to 400 KVA transformer outdoor 11KV / 433V of existing make and size complete all as specified and directed by Engineer-in-charge. |
| 25 | Material and labourSpray painting outer surface of transformer with two coats of synthetic enamel paint after scraping, removing, washing and cleaning of old paint,upto 400 KVA transformer 11KV / 433V completewriting capacity and MES No all as specified and directed by Engineer-in-charge. Make of paint: SHALIMAR/ASIAN/BERGER. |
| 26 | S & F in replacement of HT danger notice plate of 25cm x 20 cm x 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull andbonesin signal red colour and fixed with MS clamps, bolts and nuts of required complete all as directed. (Note : Letters and Nos shall be in local language, Hindi and English) |
| 27 | S&F in replacement of 3-phase potential transformer suitable for 11 KV/415V, 100 KVA transformer of any make complete all as specified and as directed. |
| 28 | S&F in replacement of 3-phase current transformer suitable for 11 KV/ 415V, Ratio 10/5, Burden 7.5 VA, Class 0.5, Freq 50 Hz, dry type outdoor as per IS 2705/1992 for 100 KVA transformer of any make complete all as specified and as directed |
| 29 | Supply and installationin replacement of 11 KV, single phase, outdoor oil cooled CT of ratio 100/5-5 Amp, class 0.5/ 5P10, burden 15VA to be pole mounted complete as per sample at site complete all as specified and as directed. |
| 30 | Supply and installationin replacement11 KV single phase out door oil cooled PT of ratio 11 KV/rt3/110 V/rt3/110V/rt3, Class 0.5-3, Burden 50 VA - 50VA to be pole mounted complete as per sample at site complete all as specified and as directed. |
| 31 | M&L Cross arms, bracing, supports, clamps, anticlimbing devices and back plates fabricated from sructural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed |
| 32 | Re-stretching the existing over head line consisting of 5/4/3 conductors of any size using Mechanical tool and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulatorproperly with the help of binding wire 14 SWGand re-fixing separators in its original position complete all as specified and directed by Engineer-in-charge. |
| 33 | Supplying, laying, jointing and testing in replacement of XLPE insulated heavy duty multi stranded armoured and PVC sheathed HT cable 11000 volts grade with aluminium conductor cross sectional area 120 sqmm 3 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/through pipescomplete all as specified & directed by Engineer-in- charge.Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule. |
| 34 | S&F in repair end termination joint 11 KV Outdoor type, end termination heat shrinkable of size 120-185 sqmm including thimbling, nut/bolts & washers, HV insulating tape etc. complete all as specified and as directed and directed by Engineer-in-charge. |
| 35 | Excavating in trenches in Hard and dense soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of cable etc not exc 10 Sq mtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and directed by the Engr-in-Charge. |
| 36 | Removing excavated surplus soil to a distance upto 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engr-in-Charge |
| 37 | Returning , filling in , including spreading, levelling, watering and wellramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by the Engr-in-Charge. |
| 38 | Supply and laying double wall corrugated HDPE (DWC) pipe of size (Outer Dia x Inner Dia= 160 mm x 135 mm) in trenches for protection of cable complete all as specified and directed. |
| 39 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 53295.00 and any other reduction if any from quoted amount. |