| 1 | Supply, installation, testing and commissioning copper wound step down transformer ,Outdoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT , 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 100 KVA including bushing on HT side and LT side all as per IS 1180 complete all as specified and directed.Note:- The Transformer shall be IS : 1180 (Part-I) : 2014 with maximum total loses as per energy efficiency level 2 of IS : 1180 (Part-I) : 2014 and shall comprise of the following: - (a) HT cable box onprimary side(HV)including Three Nos ofporcelain bushing with copper rods, complete all accessories as required.(b) One cable box on LV side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for XLPE insulated heavy duty armoured cablesand jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge.(d) De-hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent.(f) Thermometer pocket on tank cover |
| 2 | (g) One No 100mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two Nos earth terminals for body earthing and two No. earthing terminals for neutral earthing. (j) Rating plate and terminal marking plate. (k) Oil level gauge (l) Oil drain filter valve (m) Lifting lugs. (n) Initial filling to transformer oil with required capacity.(o)Pre-commissioning test shall be carried out by the SEI/IEM/Rep of Accepting Officer for which all arrangements shall be made by the contractor without any extra cost(p) Contractor will submit specification from approved manufacturer comprising of the above specification to Engr in Charge and take approval before placing order(q)By directional plane roller-04 Nos |
| 3 | Supplying, transporting, erecting and fixing of Steel tubular swaged pole type 410, SP-55, 11.00 metre long,complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified including painting with two coats of aluminium paint heat resistant type over one coat of red oxide primer and making 06 Nos bands/ straps with yellow and black colour (15 cm wide each) synthetic enamel paint over one coat of red oxide primer at a distance 15 cm from coping block and numbering of poles with black bituminous synthetic enamel paintin 2.5 cm height including tarring one coat on steelsurface embedded in concrete foundation complete all as specified and directed. |
| 4 | M&L for cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete including necessary steel form work and finishing the surface fair in forms for poles etc, complete all as specified and directed. |
| 5 | M&L for cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concrete including necessary steel form work and finishing the surface fair in forms for poles etc, complete all as specified and directed. |
| 6 | S&F lightning arrestor for outdoor use, expulsion type complete with all fittings, transmission class, discharge capacity 11KV 65KA complete all as specified and directed |
| 7 | S&F air break gang operated switches/ isolator for outdoor usesvertical/horizontal mounted including 12 insulators and operating mechanism for repair/renewal of broken /worn out components and insulators etc for current rating upto 200 Amps 11000 Volts completeall as specified and directed. |
| 8 | Supplying, laying or fixing, jointing and testingHT under ground electric power cable, XLPE insulated, screened , PVC bedded, galvanised steel strip or wire armoured, (conforming to ISI-7098), ISI Marked, with aluminium conductor multi stranded, heavy duty, 11000 Volts grade (earthed),of sizes 95 Sqmm ,laid in trenches/laid under floor, roads, paths or fixed on walls /on poles/in ducts etc. complete all as specified and directed. |
| 9 | S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. |
| 10 | S&F 80mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road /for fixing of solar street light all as specified and directed. |
| 11 | S&F 50mm bore galvanised steel tubing, light grade, ISI marked, for protection of under ground cable on pole/wall/under road all as specified and directed |
| 12 | S&F cross arms of mild steel channel or angle sections of required size and shape including clamps, D clamps, eye hooks, back plate with bolts, nuts and washers, welding, bending cold or hot drilling holes for bolts, insulator in any shape or size as indicated or directed and inclusive of one priming coat and two coats of aluminium paint including preparation of surfaces complete all as specified and directed. |
| 13 | M&Lanti climbing device spikes type fabricated out of MS Bar round type including nuts bolts washer and welding to two halves made to shapeto suit the cross section of the pole all as specified and directed. |
| 14 | S&Fdanger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for 25x20cm size complete all as specified and directed. |
| 15 | Supply, laying and testing in repairXLPE insulated, PVC sheathed, conforming to relevant IS, ISI marked, earthed system, armoured heavy duty, 120 Sqmm 3.5 core electric cable with aluminium conductor, 1100 Volts grade, in trenches/wall/floor/pole complete and making connection including suitable size Aluminium lugs all as specified and directed. |
| 16 | All as per ser item No 14 here-in-before but size 95 Sqmm 3.5 core |
| 17 | All as per ser item No 14 here-in-before but size70 Sqmm 3.5 core |
| 18 | All as per ser item No 14 here-in-before but size50 Sqmm 3.5 core |
| 19 | All as per ser item No 14 here-in-before but size35 Sqmm 3.5 core |
| 20 | All as per ser item No 14 here-in-before but size25 Sqmm 3.5 core |
| 21 | All as per ser item No 14 here-in-before but size10 Sqmm 2 core |
| 22 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in soft/loose soil complete all as specified and directed. |
| 23 | Returning, filling in excavated soil in trenches including spreading, levelling, watering and well rammingin layers n. exc. 25 cm thick complete all as specified and directed. |
| 24 | Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 25 | M&Llocal sand dry, filling in trenches around under ground cable complete all as specified and directed. Note:- Measurement shall be taken only after punning down sand cushioning. |
| 26 | Supplying and laying reinforced precast concrete cable cover class HV, Type1, flat, size 300mm x 180mm 40mm complete all as specified and directed by Engineer-in-charge. |
| 27 | Supplying and laying reinforced precast concrete cable cover class LV, Type1, flat, size 250mm x 150mm 40mm complete all as specified and directed by Engineer-in-charge. |
| 28 | M&L for earthing complete with galvanised iron earth plate electrode 600x600 and 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with 32x6mm size GI strip as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test pointetc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and directed by Engineer-In-Charge.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. |
| 29 | All as per item No 27 here-in-beforebut GI earth lead 4 mm dia |
| 30 | S&F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 Volts with accuracy ±1% and speed of correction 50 Volts per second and of capacity 100 KVA including suitable size of PCC Plinth and cover shed of Angle Iron and CGI sheet as per direction by Engineer-in-charge . |
| 31 | S&F Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 Volts with accuracy ±1% and speed of correction 50 Volts per second and of capacity 200 KVA including suitable size of PCC Plinth and cover shed of Angle Iron and CGI sheet as per direction by Engineer-in-Charge . |
| 32 | Supply, fixing, installation, testing and commissioning of new LT distribution panel board out door based type suitable using for 3 phase 4 wire 415 volt 50 HZ AC supply system with cubical shape factory fabricated and assembled with made out of CRCA mild steel sheet of 3.15 mm thick with epoxy powder coated painted and with having CPRI type test certified including making it totally enclosed weather, dust & vermin proof with having double door system and dully fabricated on MS based channel fram work along with cutting, drilling ,bending and welding hot & cold with hinges, clamp, nut & bolt etc and including making necessary louvers, gasket ,air vent and both front and rear side door opening and locking system and including consisting of nos of required incoming/outgoing feeder compartments with mounting channel along with providing of main three phase & neutral copper bus bar of current rating capacity 450 Amps and duly cover with PVC colour heat shrinkable sleeve as per phase sequence system and duly fixed on insulator complete along with suitable current rating capacity of copper sub distribution bus bar of three phase panelling system for fixing ofinter connection of incoming/out going feeder based on the load and duly attached it with main bus bar system and including cover with PVC colour heat sinkable sleeve as per the phase sequence including providing of digital type volt meter and amp meter of maximum range based on panel design load alongwith indication RYB lamp and suitable type CT with ratio of three phase system and also providing of internal control wiring for display & metering eqpt system with multi stranded copper wire complete and including also providing and comprising along with the following mentioned nos of incoming and out going controlling and operating fitted fixture with fitting accessories, cable grand and earth terminal point andincluding all the items are dully fixed on inside area of panel board system and providing of danger notice board on both side outer body area of LT panel board complete system work . |
| 33 | Incoming -(a) MCCB of rating capacity 250 Amps 4 pole 36 KA 415 Volts with having adjustable thermal setting type complete- 01 No Outgoing - (b) MCCB of rating capacity 200 Amps 4 pole 25 KA 415 Volts with having adjustable thermal setting type complete- 04 Nos (c) MCCB of rating capacity 160 Amps 4 pole 25 KA 415 Volts with having adjustable thermal setting type complete - 02 Nos (d) MCCB of rating capacity 100 Amps 4 pole 25 KA 415 Volts with having adjustable thermal setting type complete - 01 No(e) Digital type voltmeter0-500 Volts.-01 No(f) Digital type Ammeter with CT of suitable ratio for reading upto 500 Amps load-01 No(g) Indicating LED lamps R,Y& B -01 set |
| 34 | All as per ser item 31 here-in-before but providing and comprising along with the following mentioned nos of incoming and out going controlling and operating fitted fixture with fitting accessories with main three phase & neutral copper bus bar of current rating capacity 350 Amps etc for LT panel board system work complete all as specified & directed by EIC. Incoming -(a) MCCB of rating capacity 200 Amps 4 pole 25 KA 415 Volts with having adjustable thermal setting type complete- 01 No Outgoing -(b) MCCB of rating capacity 160 Amps 3 pole 25 KA 415 Volts with having adjustable thermal setting type complete- 03 Nos (c) MCCB of rating capacity 100 Amps 3 pole 25 KA 415 Volts with having adjustable thermal setting type complete - 01 No(d) MCCB of rating capacity 40/63 Amps 3 pole 16 KA 415 Volts with having adjustable thermal setting type complete - 02 Nos (e) Digital type voltmeter0-500 Volts.-01 No(f) Digital type Ammeter with CT of suitable ratio for reading upto 400 Amps load-01 No(g) Indicating LED lamps R,Y& B -01 set |
| 35 | S&F of recessed /ceiling concealed mounted flat type rectangular sizedecorative ceiling LED luminaire tube light panel fitting of rating capacity in 33W/36 Watts of size/type 1\"x4\" (width x length) with electronic driver complete light fitting set of colour warm/whiteincluding making in additional extra corner cutting work on existing hole of ceiling surface (when if required at site) for setting & fixing of new light fitting complete and also providing of suitable type of flat flexible two/three core cable and making electric connection and including taking down of old fitting all as specified and directed. |
| 36 | Supply, installation, Testing & Commissioning ofElectric storage water heater (vertical type) 50 litres, with porcelain enamel glass lined inner tank 230 V, AC, Single phase, IS 2082 Marked, 5 Star rating, with 15mm brass non return valve and including connecting fasteners not less than 100 mm with suitable nut, bolt & washers grouted in walls with complete masonry work for proper mounting of Geyser fastening bolts etc as directed as site requirement and making necessary inlet and outlet water & electric connection tested on load including provision ofPVC insulated & PVC sheathed copper conductor cable 2.5 sqmm 3 core upto 15 Amps plug pointcomplete all as specified and directed. |
| 37 | Supply, fixing, commissioning and testing of 3 star rated wall mounted split AC, dual invertor based with cooling and heating function and digital inverter type complete set of hi wall split type indoor and outdoor complete set of air conditioner unit with cordless remote control and full filling of initial refrigent gas alongwith having inbuilt heating and cooling arrangement and digital inverter twin rotary type compressor suitable for AC of rating capacity 2.0 TR and suitable for operation of 230 Volts 50Hz single phase electric supply including provn of MS stand & bracket for fixing of outdoor and indoor unit system and also providing of both type /size sanction and discharge copper refrigerant piping attachment system of any length and duly both connected it from outdoor unit to indoor unit system alongwith duly overlapped it by nitrile insulation, with insulation taping work and suitable drain pipe line system upto ground level for dropping out the water outside from evaporator unit and making electric connection with three core copper cable of suitable size and making hole on wall / roof and making good all disturbed surface as per existingcomplete all as specified and directed by EIC |
| 38 | S&F of sheet metal enclosure duly powder coated with single pole and neural enclosure with having a two pin and earth plug & top and mounting channel alongwith one 01 MCB SP 32 Amp and dully fixed surface on wall or concealed in wall and making all necessary electrical connection including taking down of existing DBs a as required at site or directed complete all as specified and directed. |
| 39 | S&F street light panel6 KW confirming to IS/ IES60947-4-1suitable for three phase MCB rating 63 amps on /off timer Astronomical, contactor rating 63 Amp including internal wiring in built short circuit protection, IP-54 complete all as specified and directed. |
| 40 | Supply, fixing, commissioning and testing of wall mounting hanging based automatic digital operation based voltage stabilizer with copper winding based unit of single phase naturally air cooled indoor type with having digital display and suitable for operation on single phase AC supply and with having designed voltage for input & output voltage 90 volt to 230 volt with accuracy +2.5% and having low and high voltage cut low voltage cut off 90 (-) 5 volts high voltage cut off 230 V (+5) Volts along with start time delay system with time delay adjustable from 30 second to 1.5 minutes system complete unit set of rating capacity 5 KVA complete system all as specified and directed. |
| 41 | S&F of sub main wiring system with two runs PVC insulated FRLS wire,1100 Volts grade with multistranded copper conductor wire of size2 Run of 6 Sqmm and 1 Run of 6 Sqmm (Nominal area) (ISI Marked) any type any length drawn through in heavy dutyISI markPVC Casing capping / PVC conduit of suitable size along with its all fittingsand connected accessories and duly fixed concealed on wall or surface on wall includingtaking down old unserviceable sub main wiring system complete and making good all disturbed surfaces match to the existing surface complete all as specified and directed . Note: 3 runs of 6 Square mm cable and 1 run of PVC casing capping / PVC conduit with accessories shall be measured as 1 unit of running metre. |
| 42 | Supply ,fixing , jointing & testing and of Hi wall mounted hanging type heating based hot system indoor fan coil units (FCU) with hanging base bracket frame complete setand operating on single phase supply voltage system 230 volt 50Hz with havingFCU rated capacity 3000 Kcal or 1.0 Ton unit system along with having inbuilt fixing & fixture complete accessories like circulation copper tube/coil and fins , blower fan with motor and front grill with PCB along with operating display control panel with hand operating remote control etc along with providing of both type of copper pipe line in let and out let hot water circulation pipe line system with connector/adaptor for fixing of flexible pipe line/valve system complete unitand suitable using it for operation of hot water circulation system including making of electrical /water pipe line connection of work complete work all as specified & directed by EIC. |
| 43 | M&L copper busbar 160 Amps capacity, 415 Volts colour code with neutral including160 Amps MCCB three phase and natural with enclose including indication lamp, Angle iron leg and PCC foundation complete all as specified and directed. |
| 44 | M&L for road cutting of minimum sizes 30cm x 30cm and minimum width of 3 mtrs for laying cables etc and makinggood the disturbed surface to match existing surface using PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed. |
| 45 | Dismantling existing unserviceable insulators of any type from pole including pins complete all as specified and directed. |
| 46 | Dismantling existing unserviceable cross arm of steel channel any type from pole including pins complete all as specified and directed. |
| 47 | Taking down existing unserviceable LT over head ACSR conductor of any size / description complete all as specified and directed. |
| 48 | S&F thermo plastic street light sintex box of size 280mm X 170 mmX 120 mm fixed on polewith the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box all as specified and directed. |
| 49 | S&F in renewal of flexible type round PVC bedded with PVC insulated and sheathed with multi FRLS cable of 1100 Volts grade with multistranded copper conductor wire of size 1.5 Sq.mm 3 core type (Nominal area) ISI Marked complete, all as specified and directed by Engr-in-Charge . |
| 50 | S&F ofrigid non metallic PVC conduit of size 15/20 mm bore heavy duty with all fitting laid in trenches/ wall including providing clamping arrangement for holding of pipe on wall inproper size of clamps, nut bolt ,and washer etc completeall as specified and directed. |
| 51 | Supply, Installation, testing and commissioning 20 Watts All-in-One Solar Street Light powder coated aluminium extruded housing as IS 16107 with following specifications, all as specified and directed by Engr in Charge:-(a) Fully Integrated Intelligent Designed Luminaire.(b) 100% Solar Powered with high efficiency mono crystalline solar PV.(c) High efficacy LED.(d) Dimensions 855mm x 380mm x 56mm ±5 mm.(e) Built-In PIR Sensor.(f) Automatically control the dimming and brightness of light to increase the backup time.(g) MPPT solar charge controller.(h) Aluminium extruded body.(j) Rust-Proof Aluminium Housing.(k) Protection IP 65.(l) Visual Angle 120°.(m) Autonomy 24 Hrs With intelligent dimming.(n) Correlated Colour Temperature 5700K.(o) Colour Rendering Index ≥70. |
| 52 | (p) Operating Temperature Range: -0°C to +50(q) Charge Controller Efficiency ≥94%.(r) LED Lamp Life 50000 Hours.(s) Solar Charge Controller MPPT.(t) System Wattage 20 W.(u) Solar Panel 50WP (±4W). (v) Luminaire efficacy >4830 Lm/Watt.(v) Battery (Lithium Ferro Phosphate4) 12.8V 24 Ah (BIS Certified) with in build BMS technology.(w) Protections: (i) Over charge (il) Deep discharge (iii) Over current (iv) Short circuit (v) Over voltage (vi) Low voltage & charging indication.(x) The LED chip used shall be any one of Osram, Lumileds, Cree, Nischia. |