| 1 | CIVIL WORKS |
| 2 | Surface dressing of ground including removing vegetation in equalities not exceeding 15 cm deep anddisposal of rubbish lead upto 50 m and lift upto 1.5 m.a. Ordinary soil |
| 3 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a) All Kinds of Soil |
| 4 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundationpipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sidesand ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal ofsurplus excavated soil as directed within a lead of 50 m. a. All kind of soil |
| 5 | Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantledmaterials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately)A.Bitumenous course |
| 6 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 7 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 8 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand) in foundation upto plinth level |
| 9 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand) in foundation upto plinth level Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 10 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a) All works upto plinth level |
| 11 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stoneaggrt. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in:a. All works upto plinth level |
| 12 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a) All works upto plinth level |
| 13 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) b) In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level |
| 14 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c) In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level |
| 15 | Reinforced cement concrete work 1:1½:3 (1 cement: 1½ coarse sand: 3 granitic or basaltic stone aggreate 20mm nominal size excluding plastering and cost of centering, shuttering & reinforcement, in sloping or battering surface (slabs, beams, louvers, etc) i) Where inclination to the horizontal does not exceed 30° |
| 16 | Centering & shuttering including Strutting, Propping & removal of forms for : Foundation Footings Bases of Column |
| 17 | Centering & shuttering including Strutting, Propping & removal of forms for :Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan) |
| 18 | Centering & shuttering including Strutting, Propping & removal of forms for :Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 19 | Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded platesWhere inclination to the horizontal does not exceed 30° requiring shuttering on the underside only |
| 20 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 21 | Providing and fixing Powder coated Gl Railing at Road Circle using G.I SHS 40x40x2 mm,25x25x2mm,25x25x2 mm vertical & horizontal & top side Design, rectangular hollow section measuring50x25x2 mm. Provision for anchor fastning including the cost of welding.IncludingTransportation,loading and unloading etc complete as directed by Engineer-In-Charge. |
| 22 | Providing and fixing Powder coated Gl Railing at Road Circle using Vertical Column 3\" GI pipe,Outer Frame & Center Design 12mm Sq bar for vertical & horizontal & top side Design.As instructedby Engg In-charge. |
| 23 | Providing and fixing laser cutting OM shape design size 0.6x0.6x3.2 mm etc complete as directed byEngineer-In-Charge |
| 24 | Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks.Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providingand Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in theratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure withsprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All thechemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent |
| 25 | Wood Finish Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system, with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) along with printed matt having wooden textures, used along with UV Resistant resin to give the clear wooden texture on the door. The core of shutter will be filled as specified (Expanded Polystyrene Foam / Polyurethane Foam (EPS/PU) Foam) The shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) Technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory. Accessories:ii) S. S. Hinges 4” - 3 Noiiii) S. S. Latch - 1 Noiiiiii) Tower Bolt 5” - 2 Nosiviv) Handle 5” - 2 Nos B) 35 MM |
| 26 | Providing and fixing factory made panelled door shutter fabricated out of second class teak wood withstyles top and middle rail and lock and bottom rail, with Navopan or equivalent plain particle boardexterior grade as per IS-3087 (1985) type I including anodized aluminium butt hinges with necessaryscrews etc. completeb.12 mm thick panel (ii) 35 mm thick panel |
| 27 | FRP (Fiber Reinforced Polymer) Frames with Wood Finish Manufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company. Specified Cross Section b) 4\"\" x 2\"\" |
| 28 | Supply and installation of Aluminium Louvers. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately) |
| 29 | Providing and fixing Azulejos tiles of size 150 mm x 150 mm true to line and level in cement mortar1:3 (1 cement : 3 fine sand) in dado as per approved design on the prepared surface including allnecessary scaffoldings, pigments, vendoring surfaces smooth, clean and dry etc. complete and the totalwork should be treated for anti-fungus, moss, etc. |
| 30 | Providing 25 mm thick cuddapah slabs machine cut and polished on either side in partitions including making necessary grooves in the wall and fixing with cement mortar, complete as directed by the engineer-in-charge |
| 31 | Providing and fixing vitrified matt finished (600x600) and 10mm thick tiles in floor, treads of steps,landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 32 | Providing and fixing vitrified antiskid tiles (320x320) and 10mm thick tiles in floor, treads of steps,landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 33 | Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete. Wall Ceramic Glazed Tiles 300 x 450 |
| 34 | 6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand) |
| 35 | 12mm cement plaster 1:4 (1 cement : 4 coarse sand) |
| 36 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 37 | Neat Cement punning |
| 38 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 39 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 40 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 41 | Providing and fixing white vitereous china pedestal type (Europen type) water closet with seat as lid, whth C.I. brass hinges and rubber fitings 15 lts white vitreous china low level flushing cistern with fittings as brackets 40 mm white precelain 3enameled flush bad, 25 mm overflow pipe with specials and mosquito proof coupling of approved municipal design complete, including cutting and making good the walls and floors where required.a)W.C. pan with white plastic seat and lid |
| 42 | Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required.aFlat back wash basin size 630 x 450mm with a pair of 15 mm C.P. brass pillar taps. |
| 43 | Providing & fixing (4’) 100 mm sand cast iron grating for gully floor or nahni trap. |
| 44 | Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws b) 600 x 20 mm size |
| 45 | Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw |
| 46 | Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore: 45 cm (18\"\" length |
| 47 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : b150 x 100 mm size –P or S type |
| 48 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 49 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: a) 110 mm dia |
| 50 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: b) 75mm dia |
| 51 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. A) 110mm dia |
| 52 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. B) 75mm dia |
| 53 | Providing and fixing rigid PVC bend (approved make) for S.W.R. pipes including lubricating etc complete bend with door : a) 100mm dia |
| 54 | Providing and fixing rigid PVC bend (approved make) for S.W.R. pipes including lubricating etc complete bend with door : b) 75mm dia |
| 55 | PProviding and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door: a) 100 mm dia |
| 56 | Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, with door : b) 75 mm dia |
| 57 | Providing and fixing single Tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, with door : a) 110 mm dia |
| 58 | Providing and fixing single Tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, with door : b) 75mm dia |
| 59 | Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes includinglubricating etc complete, without door :b. 75 mm dia |
| 60 | Providing and fixing U.P.V.C. pipe clips (approved make) for S.W.R. pipes : a) 110 mm dia |
| 61 | Providing and fixing U.P.V.C. pipe clips (approved make) for S.W.R. pipes : b) 75 mm dia |
| 62 | Providing and fixing R.P.V.C. vent cowl: b) 75mm dia |
| 63 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 a) 15 mm nominal bore |
| 64 | Providing and fixing NICKEL chrome plated copper alloy Fancy two way long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993 a) 15mm nominal bore |
| 65 | Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993 a) 15 mm nominal bore |
| 66 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). e) 40 mm outer dia CPVC Pipe |
| 67 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. a) 15 mm dia nominal outer dia pipe |
| 68 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. b) 20 mm dia nominal outer dia pipe |
| 69 | Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete. |
| 70 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 71 | Providing & fixing angular stop cock with wall flange of 20 mm dia bore without tap. Of first quality chrome. JAGUAR FLR-5053N or equivelant etc. complete |
| 72 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a60 mm thick in all colours except grey (M35 grade) |
| 73 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. b60 mm thick in Grey colour (M35 grade) |
| 74 | Supplying and fixing Pre-cast cement concrete kerbstones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification b) Size 30 cm L x 40 cm H x 15 cm T |
| 75 | Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measuredin stacks will be reduced by 20% for payment). |
| 76 | H.D.P.E. 500 Litres capacity water storage Tanks |
| 77 | Providing and fixing C.P. brass shower rose with 15 or 20 mm. Inlet: |
| 78 | Removing white or colour wash by scrapping, sand papering and preparing surface smooth includingnecessary repairs to scratches etc. Complete |
| 79 | Crack filler for plasters, IPS, cement sand screeds and non – structural cracks. Do Not open thecracks, Clean the cracks so as to free them from oil, dust, loose particles etc. Moisten the surface withwater, Fill cracks with EPCO – ACR using spatula or a putty knife. While applying avoid formationof cavity or bubbles. After filling , allow the surface to dry for at least 24 hours. Apply in layers at 24hours interval. If the depth of the crack is more than 10mm. incl. cost of scaffolding transport etc. asper dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalen. |
| 80 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such asDulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat ofsurface treatment Extra for painting on walls on the outside at height more than 10m from groundlevel for every additional height of 3.0 m or part thereof. |
| 81 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in allshade or new work over and under coat of suitable shade with ordinary paint of approved brand andmanufacture to give an even shade |
| 82 | Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50meters lead for thickness of tiles 10mm to 25mm. |
| 83 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 84 | Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape andpreparing and plastering the surface of the walls complete including disposal of rubbish to thedumping ground within 50m lead.With cement mortar 1:4 (1 cement : 4 fine sand) Please Enable Macros to View BoQ information |