| 1 | fo|qr uxjh; forj.k [k.M] cqyUn\"kgj ds vUrxZr iw.kZ tek ;kstuk en esa fofHkUu 33@11 ds0oh0 fo|qr midsUnzksa ds dk;Z{ks= esa 33 dsoh ,oa 11 dsoh fo|qr ykbZuksa dks LFkkukUrfjr djus dk dk;ZA |
| 2 | Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 60 Kms. |
| 3 | S.T Pole 13 Mtr. Long |
| 4 | S.T Pole 11 Mtr. Long |
| 5 | PCC Pole 11 Mtr. Long |
| 6 | Carriage of All line Material from store center BSR to j.e store Sub station as ACSR Weasel conductor, Dog conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Pin Insulator. Disc Insulator, 33kv & 11kv X Arme, 33kv XLPE cable etc. |
| 7 | Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 8 | Erection of Double pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 9 | Erection of Tri pole/Section Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 10 | Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 11 | Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 12 | Grouting of Tri pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work. |
| 13 | Carriage of All line Material from J.E store Sub station to Pit Site ACSR Weasel conductor, Dog conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Pin Insulator. Disc Insulator, 33kv & 11kv X Arme, 33kv XLPE cable etc. |
| 14 | Cutting /drilling /Welding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line. |
| 15 | Fixing of 33kv/11 Kv Stay rod with Stay wire in proper way with Nozelling |
| 16 | Grouting of 33kv/11 Kv Stay rods |
| 17 | Guarding of 11/33 K V line at road crossing by laying 3 Nos. Gl wire of size 6/8 SWG parallel and fixing of lacings (Tilli) at a distance at 1.5 mlrs as per direction of supervising engineer/RESPO mannual it. Includes the cost of labour,T&P carrier etc. required lor proper completing of work |
| 18 | Laying, sagging. Stringing and binding and jumpering of ACSR Weisal , rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work. |
| 19 | ACSR Wiscel/Dog conductor |
| 20 | Fixing of Earthing rod |
| 21 | Providing & Fixing of Danger Board |
| 22 | Fixing of 33 KV DISC insulator with fitting |
| 23 | Fixing of 33 KV/11KV F Braket |
| 24 | Fixing of 33 KV PIN |
| 25 | Fixing of 11 kv pin insulator |
| 26 | Fixing 11 kv disc insulator with fitting |
| 27 | Fixing of 11 KV V Type X rm |
| 28 | Fixing of 33 KV V Type X rm |
| 29 | Fixing of Top/Drop Channel |
| 30 | Fixing of MS T Off Channel |
| 31 | Fixing of MS Clamp |
| 32 | Fixing of Nut & Bolt off size |
| 33 | Providing Fixing of ston pad |
| 34 | Providing & Fixing of Barbed wire |
| 35 | Providing & Fixing of All. Bindind wire |
| 36 | Providing & Fixing of All. Paint |
| 37 | Providing & Fixing of PG clamp |
| 38 | Providing & Fixing of Red oxied Paint |
| 39 | Providing & Fixing of LT Shekle insulator |
| 40 | Making open ternch for under ground Cable. |
| 41 | Laying of 33 KV XLPE Cable in Open trench with send and bricks in double circuit and laveling the trench as before. |
| 42 | Providing And Fixing Of Heat Shrinkable Cable Jointing Kit Indoor & Outdoor Suitable For off size XLPE Cable |
| 43 | Hoisting of 33 KV off size XLPE Cable On Double Pole/Four Poles Structure through GI Pipe off size Fixed On Pole Structure Including its Jumpring Complete with Clamps Bolts and Nuts. |
| 44 | Providing and Fixing of GI Pipe 6 mm dia & For hoisting |
| 45 | The folloing material is required to be supplied by the contractor. |
| 46 | Providing of MS Clamp |
| 47 | Providing of Nut & Bolt off size |
| 48 | Providing of ston pad |
| 49 | Providing of 33 Kv F Bracket |
| 50 | Recive back material. |
| 51 | OLD & Used Damaged ST Pole Scrap |
| 52 | MS scrab |
| 53 | ACSR condctor wire scrab Please Enable Macros to View BoQ information |