| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames with shutters n.exc 1.5 sqm each(without taking off shutters from the frame) and removing from site all as directed. |
| 2 | Taking down chowkhats or frames with shutters but exc 1.5 sqm but n.exc 4sqm each complete all as specified and directed . |
| 3 | Taking downshutters exc 1sqm but not exc 2 sqm each and removing from site all as directed. |
| 4 | S&F Framed work such as grills, gratings, chowkhats of angle/channel section etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; gates, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete, all as specified and directed |
| 5 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mmthick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.(Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified. |
| 6 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete.all as specified and directed. |
| 7 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). ® Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. complete.all as specified and directed. |
| 8 | S&F 100 mm sizebutt hinges, medium weight , coldrolled, mild steel and fixedcomplete all as specified and directed |
| 9 | S&F Stainless steel barrel tower bolt 125mm long extruded section all as specified. |
| 10 | S&F 150mm size Stainless steel handles fabricated type anodised complete all as specified. |
| 11 | S&F 300mm long aluminium alloy anodised sliding bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts and extruded section or cast aluminium alloy and fixed complete. |
| 12 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) or openable type/casement windows upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 13 | Supply and fixing factory made uPVC white colourCasement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.50 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-inCharge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 14 | Supply and fixing factory made uPVC white colour Two track two panels sliding glazed window upto1.50m height made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall beacceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 15 | Supply and fixing factory made uPVC white colour fixed glazed window/ ventilator/ partition made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimensioncomprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion weldedat all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 16 | Supply and fixing factory made uPVC white colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm) Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of\"zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass and stainless steel wiremesh. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each. |
| 17 | S&F for20 to 25 mm dia stainless steeldraperycurtain rod withbrass /nickel chrom polish / designer lattos and brackets complete all as specified and approved by Engr-in-Charge including taking out old pelmet with curtain rods all as directed.directed . |
| 18 | S&F Stainless steel wire cloth, 0.56mm nominal dia of wire & average width of aperture 1.18mm with stainless steel wire staples complete all as specified and directed . |
| 19 | S&F 4.8mm thick ordinary sheet glass and glazing with oil putty complete in squares not exc 0.50 Sqm each pane complete all as specified and as directed. |
| 20 | S&F 4.8mm mm thick ordinary sheet glass and glazing with oil putty complete in squares exc 0.50 Sqm each pane complete all as specified and as directed. |
| 21 | Demolition of brick work built in cement mortar incl all quoins, arches, pillars etccomplete all as specifiedand as directed. |
| 22 | M&L for brick work with sub class \"B\" bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1:6 complete all as specifiedand as directed. |
| 23 | M&L for 1/2 brick work withsub class\"B\" bricks , usingold sizebricks, straight or curvedon plan exc 6 m meanradius built in cement mortar1:4 complete all as specified and directed. |
| 24 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified. |
| 25 | M&L for Rendering 15mm thick (1:6) on fair faces of brick work or concrete surfaces mixed with water proofing for Internal Wall finished even and fair without using extra cement complete all as specified and directed. |
| 26 | M&L for Rendering 15mm thick (1:4) on fair faces of brick work or concrete surfaces mixed with waterproofing compound External Wallfinished even and fair without using extra cement complete all as specified and directed.(Note : WPC Shall measured and paid separately) |
| 27 | M&L for rendering 5mm thick (1:3) plaster onceiling concretesurface in cement mortar, finished even and fair without using extra cement complete all as specified and directed. |
| 28 | M&L preparation of new surface of wall and applying 2-3 mm thick JK/BIRLA white wall care putty and applying two coats of plastic emulsion paint over a coat of oil based primer complete all as specified and directed |
| 29 | M&L for preparation of newly plastered surfaces of any description and applying two coats of cement base paint all as specified and directed. |
| 30 | M&L for preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces all as specified and directed. |
| 31 | M&L for preparation of new plastered of ceiling and applying three coats of white wash as in ceiling complete all as specified and directed. |
| 32 | M&L for complete removal of existing treatment by mechanical/manual means and applying one coat of 3mm thick wall care putty (Birla white or equivalent) in two layers and applying two coats of oil bound distemper over a after preparation of on old wall surfaces complete all as specified and directed. |
| 33 | M&L for preparation of old plastered or unplastered surfaces of ceiling and applying two coat of white wash as in ceiling complete all as specified and directed. |
| 34 | M/L for preparation of old plastered surfaces of wall of any description and applying two coats of cement base paint all as specified and directed. |
| 35 | M&L for applying two coats of cement base paint, white or tinted on new wall surface including preparation of surface complete as |
| 36 | M & L for preparing new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of alkali resistant cement primer and over a coat of 2 to 3mm thickwall care putty complete all as specified and directed. |
| 37 | Material and Labour forapply two coats of Anti fungal weather coat acrylic emulsion paint over a coat of primer on new surfaces including 2 -3 mm thick wall putty, complete all as specified and directed. Make of Arcylic emulsion weather coat paint:-Asian (Apex Ultima) ,Berger (Super coat ) or ICI Dulux (weather shield) .Make of primer :- Asian (X2) or Equivalent . Note:- (a) Each stage i.e. preparation of surfaces, application of primer, application of first coat, application of second coat will be got passed from Engr-in -Charge.(b)Written Warranty for four years or as per manufacturer\"s instructions, whichever is more is required to be furnishedby contractor for this item. |
| 38 | M & L for preparing new plastered surface on ceilingand applying two coat of oil bound distemper complete all as specified anddirected. |
| 39 | M&L for preparation ofold decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andapplying two coat of Oil bound distemper on walls over 2mm thick plaster of paris putty as specified and directed by Engr-in-Charge. |
| 40 | M&L for preparation ofold decorated plastered or unplastered surface including complete removal by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andFinishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) on walls over 2mm thick plaster of paris putty as specified and directed by Engr-in-Charge. |
| 41 | M&L for old ceiling surfaces two coat of oil bound distemper on old surface on ceilingincluding complete removal preparation of old surface complete all as specified and directed. |
| 42 | Dismantling of floor, hearth or wall tiling with cement mortar bedding, tucking and roughening of wall and floor, backingand dispose rubbish out off the premises complete in all respect all as specified and directed. |
| 43 | Dismantling Stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc. complete all as specified. |
| 44 | M & L 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded aggregate) for levelling course in floors complete all as specified anddirected. |
| 45 | M&Lfor Coloured digital dark shade Double charged/ultracharged vitrified tiles 10mm thick in floorexc 0.42Sqm but n.exc 1.00Sqmeach tile area set and jointed in neat cement slurry and pointed with white cement with pigment to match the shade of tile over and including screed bedding 15mm in CM 1:6 complete in all respect all as specified and directed. |
| 46 | M&L for Coloured digital dark shade Double charged/ultracharged vitrified tiles but on vertical surface as in dados/skirting over 10.mm thick plaster as backing coat in CM 1:4 all as specified |
| 47 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.11 sqm but nexc 0.18 sqm, in floors etc. set & jointed,with neat cement slurry and pointed white cement with pigment over 15mm thick screed bed or bedding layer of mortar in cement mortar (1:6) for laying of tilescomplete in all respect all as specified and directed. |
| 48 | M&Lfor Glazed ceramic coloured digital wall tiles joints free of size area exc 0.06Sqm and not exc 0.18Sqm X7-8mm thick set and jointed , Joints are filled with , Fevimate TG tile groutof Dr Fixit over and including 10mm thick rendering in CM 1:4complete in all respect all as specified and directed. |
| 49 | Supply only Liquid waterproofing compound complete all as specified and directed |
| 50 | M&L for Acid resistant tiles 15mm thick vitreousceramic, unglazed, set, jointed and pointed inchemical resistant mortar, resin type, in floors set & jointed,with neat cement slurry and pointed white cement with pigment over 15mm thick screed bed or bedding layer of mortar in cement mortar (1:6) for laying of tilescomplete in all respect all as specified and directed. |
| 51 | M&L for antistatic epoxy flooring 3mm thick in floors, including a 2mm thick hardener screed compound followed by 1mm layer of semi-liquid epoxy resin for smoothness over a smooth concrete surface complete in all respect all as specified and directed. |
| 52 | M&L Granite stone slab18 to 19 mm thick machine cut polished of colour as required, bedded and jointed in neat cement slurry and pointed in white cement with pigment to match colour of granite stone with and including screed bed of 20mm thick in cement mortar 1:6 all as directed and specified |
| 53 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor (40 mm graded stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc completeall as specified and directed. |
| 54 | M&L 20 to 25mm thick prepolished machine cut Kota stone slab as in flooring over and including 15mm thick screed bed in cement mortar 1:6, laid over cement slurry @3 Kg/Sam and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge of slab complete all as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above). |
| 55 | M&L 20 to 25mm thick prepolished machine cut Kota stone slab as in riser or vertical surface over or as in skiing and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge where as specified and as directedNote The size of Kota stone slab shall not less than 550mm x 550mm cut size as in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above). |
| 56 | M&L for 50mm thick type-D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base to receive Chequered Cement Concrete tiles and paver blocks all as specified and directed. |
| 57 | M&L for PU Coating Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set. iointed and pointed in neat cement slurry in floors etc. set and jointed in neat cement slurry and pointed in for laying floor finishes CM (1:4) complete all as specified and as directed white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick |
| 58 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed. |
| 59 | M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth on stone walls complete all as specified and directed. |
| 60 | M&L for RCC (nominal mix) type B-01:2:4 (12.50mm graded crushed stone aggregate) as in Chajjasslab and the like complete all as specified and directed. |
| 61 | M&L RCC Foundations, including raits, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete uing type M-25(Design mix) (using 20mm graded) stone aggregate complete all as specified. |
| 62 | M&L RCC type B-1 1:2:4 using 20mm graded stone aggregateas in kitchen shelves , manhole cover, etccomplete all as specified and directed. |
| 63 | M&L RCC in Columns, pillars, piers, posts and struts uing type M-25(Design mix) (using 20mm graded) stone aggregate complete all as specified. |
| 64 | M&L Reinforced Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete (reinforcement to be measured separately). |
| 65 | M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality all as specified and directed. |
| 66 | M&L Mild steel TMT bars 6 to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns. hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or secuting with clips as in stirrups quality complete all as specified. |
| 67 | M&L for use & waste of form work using steel sheets, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.Note:- Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured. |
| 68 | Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified. |
| 69 | Form work to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified. |
| 70 | Formwork to Chajjas, slab ,chullah hoods, kitchen shelves cupboards, suspended slabs, drain slabs troughs and similar items including edges rough finished surfaces complete all as specified and directed. |
| 71 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc20cm wide and sides of RCIPCC bands in walls, horizontal or sloping and sillar work exc 5cm but not exc 10cm wide |
| 72 | Formwork to soffits of slabs n. exc. 200mm thick and similar works rough finished surfaces of concrete complete. |
| 73 | M & L for 75mm thick cement concrete 1:3:6 type C2, with using 40mm graded stone aggregateas in plinth protection finish the surface even and smooth without using extra cement including filling the expansion joints with bitumen filler / filler boards and necessary form work etc complete all as specified and as directed. |
| 74 | Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed. |
| 75 | Excavation in trenches in soft/loose soil n exc 1.5m wide and n.exc 1.50m depth getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified. |
| 76 | Excavating in post holes (or similar holes) each in soft/loose soil n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified. |
| 77 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in hard dense soil. |
| 78 | Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point. |
| 79 | M&L for Cement Concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete |
| 80 | M&L for hard core of gauge n.exc.63mm hand broken bricks,spread and levelled in layer n exc.15cm thick watering and rammed to a true surface complete all as specified and directed. |
| 81 | M&L for 100 mm thick cement concrete type D-2 1:4:8 (40mm graded agg) as in sub floor; complete all as specified and directed. |
| 82 | M & L for Machine pressedprecast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with Grey cement and pigmentcomplete all as specified and directed. |
| 83 | M&L Sand filling under floors or in foundations including watering and consoilidation complete all as specified and directed. |
| 84 | M&L for Cement Concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specifiedand as directed. |
| 85 | M&L for providing WPC Jalli 24mm thick including fixing materials and frame work complete all as specified and directed. |
| 86 | S& F Floor door stopper of aluminium alloy bodyand tongue ,anodised ,with hard drawnsteel spring ,fixed in floor overall length of cover plate140mm |
| 87 | M & L for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed |
| 88 | S & F 12mm Thick Toughen glass partitions, Doors,including all fittings and fixtures, necessary Handles, hinges, and knobs etc as per the existing one complete all as specified and directed. |
| 89 | S & F Aluminium Composite Panel sheet of 3 mm thickwith skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30 micron fixed with suitable Self Tapping Screws over frame work of anodised aluminium tubular section 25 X 50mm, 2mm thick, duly fixed to wall / ceiling with expansion fastener, having panels not exceeding 1200X1200mm with necessary silicon filling, in approved pattern / size as in column, beam, wall etc. complete all as specified and as directed.Note:- Rate quoted is deemed to be included for necessary MS Scaffolding up to a height of 12m from the GL for carrying out the job. Nothing shall be paid extra on this account. [Make of Aluminium Composite Panel: ALSTRONG / ALCOBOND / ALSTONE] [Make of Aluminium Sections: JINDAL / HINDALCO / INDAL] |
| 90 | S&F for Anodised aluminium with powder coating of any colour thickness of coating not less than 50 microns frame for doors, windows, ventilators & partition with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 91 | S&F Anodised aluminium ith powder coating of any colour thickness of coating not less than 50 microns window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 92 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin-charge. |
| 93 | S&F Antimicrobial cladding system of thickness 2.5mm of std size 1500x3000mm having tensile strength of 52Mpa, fire resistant, chemical resistant over insulated wall panels as per specifications and drawing complete all as specified. |
| 94 | S&F lnsulated PVC Wall Lining (thickness of PVC wall lining 25mm) consisting of PVC Insulated Panels with wood grain printed PVC sheets havingexpanded polystyrene (EPS) stuck to 2mm thick plain colour PVC sheet duly fitted into the wall as per specifications and drawing complete all as specified. |
| 95 | M & L for welding in repairsof n exc 6mm thickand not exc 2.5 cm in length as directed. |
| 96 | Resecuring or easing & adjusting, without taking down shutters of any descriptionexc 1 sq. m and n exc. 2 Sq.m each complete all as specified and as directed. |
| 97 | Cutting holes in brick walls exc half brick but not exc one brick walls built in Cement mortar or cement lime mortarfor inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed. |
| 98 | S&F in repairfor Gypsum ceiling board for ceilingprepainted, perforated finish, 600 x 600 x 9 to 9.5mm thick in size, of approved brand/make, laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I. tee 32 x 24 mm for main, 25x24mm for cross tee and 20 x 20mm angle fixed on wall, powder coated finish on exposed faces of tee and angle. hung from ceiling using 2 mm thick G.I. Suspension wires spaced at 1200 mm on main runners including making niches for fans/light, including dismantling ofwall ceiling and boards,(fibere pulp, insulationetc or insulation boards of anythickness including cover fitllets. all as specified and directed. |
| 99 | Supply and laying of CPVCpipes SDR 11 of outer dia 20mm & plain CPVC SDR 11 fittings on walls/ceilings or laying in floors including taking up or down steel water tubing and connectionsand removal from site 15mm/20mm bore pipe and complete to walls, ceiling or laid in floor all as specified.(Make:- Astral or equiv) |
| 100 | Supply and laying of CPVCpipes SDR 11 of outer dia 25mm & plain CPVC SDR 11 fittings on walls/ceilings or laying in floors including taking up or down steel water tubing and connectionsand removal from site 15mm/20mm bore pipe and complete to walls, ceiling or laid in floor all as specified.(Make:- Astral or equiv) |
| 101 | S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 500 Ltrs Capacity complete. |
| 102 | S&F in repair Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I 1000 Ltrs Capacity complete. |
| 103 | S & F rotational moulded 1000 lit capacity polythelene water storage tanks ( cylindrical verticle with closed top) hoisted and fixed in position all as specified |
| 104 | S&F in Repairs bib taps with wall flange complete all as specified and directed. |
| 105 | S&F in Repairs Angular Stop cock with wall flange 15 mm bore complete all as specified and directed. |
| 106 | S&F in Repair 15 mm dia CPKithcen Sink mixturefor mixing hot and cold water with regular spout without popup waste system complete all as specified. |
| 107 | S&f Sinks without drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers & waste; including bedding in CM to dwarf wall or including fixing cantilever brackets & connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified. |
| 108 | S&F Waste fittings 40mm bore, brass, CP for glazed ware sinks, basins, etc. with long screwed shanks & fly-nuts, flange end bedded in red lead cement & other end fixed complete all as specified and directed. |
| 109 | S&F CPGratings100mm dia complete all as specified. |
| 110 | S & F in repair vitreous china wash hand basinwhite flat back of size 550x400mm including cutting for and pinning in ends of brackets,brass chromium plated waste fittingscomplete all as directed and specified. |
| 111 | S&F in repairs centre hole CP basin mixer cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, mixing\"Hot\" or \"Cold\" water with long screwed shanks and fly nuts, screwed for iron pipe and fixed of bore dia 15mm complete all as specified. |
| 112 | S&F in repair vitreous china wash down water closet pedestalpattern white excluding flushing cistern and flush pipes complete all as specified and as directed . |
| 113 | S&F health faucet with 1 meter long easy flex tube in chrome finish & wall hook, complete all as specified and directed |
| 114 | M&Lin repairs PVCvalve less,syphonic action type flushing cistern,low level ,white with inlet ball valve,float and handle including bracketsand connection to pipe and fixing of chainand pull or lever if any complete all as specified and directed. |
| 115 | S&F white vitreous china counter wash hand basin,of size-410X910X150mm fixed in granite counter by making suitable size hole, new brackets, 32mm dia brass chromium plated waste coupling, CP botle trap complete all as specified |
| 116 | S&F in repair vitreous china urinal bowl urinal flat back, size of 465x355x265mm white (min)with grating and union for discharge pipe, urinal spreader with waste pipe and all fiting for urinal. |
| 117 | S&F in repairs for 600mm x 450mm size beveled edge mirror of 6mm thick selected quality mounted on 6mm thick plywood with chromium plated screws with washer complete all as specified and directed. |
| 118 | S & F in repairs PVC (SWR) nani trap /floor trap plain or multi with stainless steel grating incl joining to waste pipe with solvent cement joint dia of outlet 75mm bore complete all as specified and as directed. |
| 119 | S&F in repair75mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
| 120 | S&FPVC (SWR)bends of 110mm boreany radius complete all as specified |
| 121 | S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 122 | S & F in repair75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 123 | S & F in repairs 110mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls /floor or in trenches complete all as specified and as directed. |
| 124 | S & F in repairs 75mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls / floor or in trenches complete all as specified and as directed. |
| 125 | Taking down of old PVC drain pipes from wall/fllor/ceiling/trenches in any position and removing to store complete all as specified. |
| 126 | S&F in repair CP mixer (wall, sink & WHB) for mixing hot & cold water screwed down for ironpipe 15mm borecomplete all as specifiedand as directed. |
| 127 | S&Fixed in repair 125 mm size chromium plated showerrosewith siwel joint suitable for 15 mm bore GI pipes comlete all as directed.. |
| 128 | S&F in repairs PVC connection15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed. |
| 129 | S&F in repair Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and as directed. |
| 130 | S&F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) |
| 131 | S & F 20mm bore gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 132 | S & F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete Make- Jaquar Cat No - CAN-1173 complete all as specified and as directed. |
| 133 | S&F75mm stack clamp out of 50mm by 5mm flat iron and 16mm dia around iron stamp incl bolts and nuts and securing ends of clamp to wall or roof complete all as specified and as directed. |
| 134 | S&F110mm stack clamp out of 50mm by 5mm flat iron and 16mm dia around iron stamp incl bolts and nuts and securing ends of clamp to wall or roof complete |
| 135 | Dismantaling plain or corrugated AC sheeting any gauge, thickness, including nainital or similar pattern roof covering all as specified and directed. |
| 136 | S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge. |
| 137 | Dismantling structuralsteel/iron workincluding doors, gates, posts, purlins but excluding framed truss etc. all as specified and directed. |
| 138 | S&F steel work in tubler trusses/posts/purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade st-240 all as specified and directed. |
| 139 | M&L cutting crack to \"V\" groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed. |
| 140 | Dismantling/removing of old roof treatment of any type including brick tiles, mud fushka etc to get the original RCC surface,cleaning with water etc complete to receive plaster/PCC and removing the debries out of MOD land all as specified. |
| 141 | Removal of Mud fromm top roof slab any thickness, including plastering and leeping (wether full thickness removed or only a part thereof) complete all as specified and directed |
| 142 | M&L for cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed. (Rate of WPC shall be included in unit rate) |
| 143 | M&L for 10 mm thick renderingover the concrete / brick roof surfaces in cement mortar 1:4 surface with water proofing compound @ 200ml per bag finished even and smooth without using extra cement all as specified and directed. |
| 144 | Cleaningall the dust and loose material by brush/blower/Grinder including removing of vegetation/plantation from the surface. M&L for preparation of roof top surfaces, providing and applying single component elastic cold applied polyurethane modified acrylic roofing system, co elastic technology (CET) based on modified polyurethane and fully fibre reinforced, having Sun Reflectivity index (SR) of 109 on top of concrete roof surfaces. All cracks up to 3 mm at corner joints, channel and parapets should be treated with crack seal. Applying three coatsincluding one coatof primer ofShaliUrethane BTD/ Sikalastic 560/ smart care damp proof-ultra having coverage @ min 0.75kg/m2and dilution up to 10% andlaying reinforced fiber net and applying two coats (without dilution) of shaliUrethane BTD/Sikalastic 560/smart care damp proof ultra@totalconsumption 2 kg/m2intwo coats for maintainingminimum dry filmthickness 1.5mm and elongation at breakof free film of approx 350%. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/Consultant (Note :6 Hrs interval between two coat will be maintained). All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Make: STP/Sika/Asian paint or equivalent as approved by GE. Note:- Application of water proofing treatment will be done by Authorised Applicator only. |
| 145 | M&L for water proofing treatment to non accessible roof and edges (vertical or tapered) / sunken portion etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 1.2Kg/Sqm and primer shall be allowed to dry over night. (iii) Laying APP based modified water proofing membrane of weight not less than 3kg per sqm and thickness not less than 3 mm, with 100mm overlaps, sealed and bonded to the surface by \"torchon\" method (iv) Applying two coat of bituminous based aluminum painting@ 0.15 kg/Sqmeach coat on water proofing treatment with preparation of surfacescomplete all as specified and directed at site. |
| 146 | M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. |
| 147 | M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris & dust(ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness.Note:-Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed. |
| 148 | M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces ofrequired thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessarychased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement.The cost of welded mes his to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed. |
| 149 | S&F Mild steel, plain black sheet 0.80mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 150 | S&F Rolled mild steel Framed work as in doors or gates of angle or Kgother section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering. running rails & guides) & hanging; also fastening & fixing complete GDE Fe410-0 or Fe 310-O complete as specified. |
| 151 | S& Fsteel work in tubular trussles, purlins, rafters, tubler column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washers etc. complete using ERW or induction butt welded tubes confirming to Fe 410W grade E 250 quality B, etc complete all as specified and directed. |
| 152 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth over one coat of red oxide, zinc chrome complete all as specified and directed . |
| 153 | S& F 0.50mm thick (including coated thickness) Pre-colour, pre-profiled (Galvalume ) sheets of required colour and design having tensile strength of 550 Mpa as in roof, wall cladding, north light curves, fixed with zinc coated self drilling fastener including EPDM washer complete laid with one corrugation side laps and min 150mm end lap laid to slope all as per manufacturer/profile maker instruction complete all as specified and directed. |
| 154 | S&FFibre glass reinforced plastic (FRP) door frames shall be three lagged of cross section 90mmx45mm having single rebae of 32mmx15mm to receive shutter of 30mm thickness.The laminate door frame moulded with fire retardant grade unsaturated polyester resin and chopped mat.Door frame moulded with fire retardant grade unsaturated polyester resin and chopped mat Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs,The frame shall be covered with fiber glass from all sides MS Stay shall be provided at the bottom to seady the frame all as specified and directed. |
| 155 | S&F FRP door shutter shall be 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufactures.Made with fire retardant agrade unsaturated polyester resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels and confirming to IS-14856-2000 |
| 156 | M&L for water proofing treatment to sunken portition / roof etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 1.2Kg/Sqm and primer shall be allowed to dry over night. (iii) Laying APP based modified water proofing membrane of weight not less than 3kg per sqm and thickness not less than 3 mm, with 100mm overlaps, sealed and bonded to the surface by \"torchon\" method (iv) Applying two coat of bituminous based aluminum painting@ 0.15 kg/Sqmeach coat on water proofing treatment with preparation of surfacescomplete all as specified and directed at site. |
| 157 | M&L for followings:-(i) Removing plaster & finishes all around the RCC member.(on all four sides of column to fult height, three sidescription of beam to entire span & bottom of slab to area as directed)(il) After cleaning gently removing cover concrete using pneumatic/electric chipper of any other extent when reinforcement is visible)approved tool in entire portion of structural member (removal of cover concrete shall be done to an (ill) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference in case of columns & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed (iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out. |
| 158 | M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-10-12 mm dia bar - drilling length 80 to 100 mmNote: Anchoring of new re-bars of any dia as directed in to the sound RC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above tor proper bonding into the concrete etc., complete all as specified and directed Note:- The cost of drilling hole & chemical anchoring with epoxy resin is included in this item |
| 159 | M&L for Providing & Pouring Micro concreting M-40 grade :-(i) Dry concrete substrate surface and free of debris & dust(i) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASFor equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer\"s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed.Note: Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item. |
| 160 | S&F for stengthening existing reinforcement by use of mild steel bars of any dia, cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specied and directed. |
| 161 | M&L for Preparing new plastered surfaces of wall and providing and applying plaster of Paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat [email protected] Itr/10 sqm over and including priming coat of exterior primer applied @2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. |
| 162 | M&L for preparation of old decorated plastered surfaces of walls, complete removal of existing treatment by rubbing, brooming down, washing with water etc and providing and applying plaster of Paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @1.67 It/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge. |
| 163 | M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sam and paste the membrane with torching method and again a cla coat of 85/25 bitumen @1.2 kg/sqm at overlapping joints. |
| 164 | S&F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78,solar reflection> 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20mm thick cement sand mortar in the ratio of 1:4 (1 cement: 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner incl 15mm thick screed bed in 1:6. |
| 165 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete |
| 166 | Taking out Unseviceable main switch DB,MCB DB existing Complete |
| 167 | M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for |
| 168 | All as per srl no.167 here in before but One light point/fan point/socket on Independent board controlled by one switch of 6Amp |
| 169 | All as per srl item No 167 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch |
| 170 | All as per Serial Item No 167 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed |
| 171 | S&F of modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed |
| 172 | S&F of modular switch, with indicator, 16 Amps, single pole, one way, 250 volts, one module complete all as specified & directed |
| 173 | S&F of modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed |
| 174 | S&F of modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed |
| 175 | S&F of repair ceiling fan modular regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete |
| 176 | S&F ceiling rose, 6 Amps, 250 volts, ACwith three terminals and PVC / Polycarbonate insulated body of 50 x 25mm sizecomplete. |
| 177 | S&F in repair surface/ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver full window glarefree opal diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete |
| 178 | S&F of wall mountedLED batten with polycarbonate housing and initigrated electronic drive20 watt fixture 4 feet provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete. |
| 179 | S&F of exhaust fans AC single phase 230/240 V of size 450 mm sweep heavy duty with louver and depositing old exhaust fan to MES store complete all as directed. |
| 180 | M&L for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 181 | All as per the description of srl item No 179 above but with 6 sqmm and 6 sqmm as earth wire |
| 182 | S&F in repair MCB DB, 12 way, single pole and neutralwith 200 Amps rated bus bar, 230 volts, glazed,double door type, IP-43,including connecting all connections of wire to MCBs with proper lugs & making good to the disturbed surface complete for the following no of way :- |
| 183 | S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following:-(a) MCCB, 100 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No. (b) MCB, SPN/SP 63A, AC,240 volts - 12 Nos. |
| 184 | S&F of MCB, 63 Amps, DP/SPN, 240 Volts, AC of breaking capacity 10 KA,\"C\" curve and connections by using suitable copper lugs complete of following rating :- |
| 185 | S&F of MCB, SP, AC, 240 volts of 6 to 32 Amps capacity \"C\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 186 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed.Note-testing of earthing after completion is in permissible limit obtained with out making extra cost. |
| 187 | S&F in repair sheet metal enclosure with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps \"C\" curve, 240 Volt complete |
| 188 | S&F in repair fans ceiling complete with blade ,down rod,electronic type regulator and accesoories 230 V, 1200 mm sweep. BLDC ,min air delivery 210 CFM with service value 6 BEE 5 star rated with brushless direct current motor energy saving and depositing old ceiling fans to MES store complete all as directed. |
| 189 | Supply and fixing in repair ultra bright compact 6/8 Watt round LED downlighter recess/surface with high efficiency LED,s idealy suited for low ceiling areas to give glare light IP-54 in 6500K with integraed driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 95 mm mm dia hight max 83 mmrecess luuminaries all as specified and directed. |
| 190 | Supply and fixing in repair 12 Watt round LED panel recess/surface mountingdownlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 145mm mm dia hight max 35mmrecess luuminaries all as specified and directed. |
| 191 | Supply and fixing in repair 15 Watt round LED panel recess/surface mountingdownlight in CDL with integraed driver to delivered superior light output and uniformity utilising the latestLED technology, ceiling cutout 145mm mm dia hight max 35mmrecess luuminaries all as specified and directed. |
| 192 | Supply and fix Air Cooled Split unit Air Conditioner Electric driven,Single phase of capacity of 1.5 TR ,BEE 5 star rated including Cooling and heating type with complete electric connection and with properly Cutting ,drillingfor making the size as suitable as directed by Engineering in charge. |
| 193 | Supply and Fix voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 to 250 V with output voltage stablizered at 230V with accuracy of 2.5% and of capacity up to 3 KVA |
| 194 | S&F Deep Freezer glass top more than 320 ltr and upto 400 ltr capacity having double door complete all as directed |
| 195 | Supply and fix Water cooler fully stainless steel electric driven (single Phase),having approx storage capacity of 80 ltr and nominal cooling capacity of 40 ltr per hr complete all as specified. |
| 196 | Supply and fix Reverse Osmosis Plant of output capacity of 25 ltr per hour, TDS controller, UV Filteration, Alkalinr water Technology, Energy Efficient & low maintenance, 08 Stage purification, Durable & leak proof design CTO, UV, Alkaline mineral filter, Low maintenance, one year warrenty complete all as specified. |
| 197 | S&F Switch piano flush type 5/6 Amps single pole one way230 Volts |
| 198 | S&F Socket Outlet 2 in 1, 3 pin 5 Ampsflush type 230 Volt |
| 199 | S&F Sheet metal enclosure DB 8 way, single pole and neutralwith 200 Amps rated bus bar,230 volts, glazed,double door type, IP-43,including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface. |
| 200 | S&F MCB DP 40 Amp, 240 Volts, AC of breaking capacity 10 KA,\"B\" curvecomplete |
| 201 | S&F of surface and wall mounted LED batten 10 watt 2 feet longextruded aluminium housing provided for efficient heat dessipation with polycarbonate diffusser and integrated electronic drive, pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and directed (Make : Havells / Philips/ Crompton) |
| 202 | S&F energy saving LED security light fittings of 35 watt with pressure die cast aluminium IP66 luminaire with high power LED As light source comprising with electric driver and all accessories prewired incld connecting up with PVC insulated copper conductor cable 1.5 sqmm ,3 core for connections and includingsuitable GI bracket for mounting of light fittings,bend to light fittings,bend to shape at required degree and fixed to wall by means of suitable flat iron clamp ,nut boltsand washers etc.complete all as specified and directed. |
| 203 | Supply and fix electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed . |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail