| 1 | Earthwork in excavation by mechanical means (hydraulic excavator ) in foundation trenches or drains (not exceeding1.5 m in width or10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5m , including getting out the excavated soil in any type of soil and disposal of surplus excavated soil as directed , within a lead of 50m complete all as specified anddirected. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cmcomplete all as specified anddirected. |
| 3 | M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed. |
| 4 | M&L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of concrete foundation and plinth beams and similar work for rough finished concrete surfaces complete all as specified and directed. |
| 5 | M&L for use and waste offormwork to sides of pillars, posts, struts, piers, columns, and stanchions etcfor rough finished surfaces of concrete complete all as specified and directed. |
| 6 | M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc, for rough finished surfaces of concrete complete all as specified and directed. |
| 7 | M&L for reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregates)as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed . |
| 8 | M&L for reinforced cement concrete M-25 (design mix)(using 20 mm graded crushed stone aggregates)as in beams, cantilevers, bressummers, lintels over 1.5m span and the like; complete all as specified anddirected . |
| 9 | M&L for reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 10 | M&L for Mild steel TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 11 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups , spacers and binders including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 12 | M&L for brick work with fly ash bricks using old size bricks, straight or curved onplan exceeding exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified anddirected . |
| 13 | M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces, surface finished even and smooth without using extra cement complete all s specified and directed. |
| 14 | M&L for plain cement concrete 1:2:4 ,type B1(using 20mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, window or door cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings,side posts of precast jallies etc. including slightly rounded or chamfered angles including necessary formwork complete all as specified and directed. |
| 15 | M&L for granite work 18 to 20 mm thick (table rubbed and polished) in steps, jambs , pillars, window cills , cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match shade of granite with full round bull nosing at edge complete all as specified and directed |
| 16 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 290(Gde- E-165) complete all as specified and directed. |
| 17 | S&F mild steel work such as in angle iron fencing posts swan neck, struts and flat iron fillets, gatesetc,cutting tops to shape as directed including drilling hole, punching,splitting ends to secure chain link fencing or fixing of barbed wire to posts including all necessary cutting, welding bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 quality complete all as specified and directed. |
| 18 | S&FGalvanised, 2 strand, steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line wire to be measured).complete all as specified anddirected. |
| 19 | S&F Concertina coil fencing with punched tape concertina coil 600 mm dia, streched to 6 meter length, having 50 Nos spiral turns per 6 meter length, spring core wire (2.59mm thick) of high tensile strength of 1620 N/sqmm with tape (0.52mm thick) hot dip galvanised upto 20 microns, weight of each coil 8.50 Kg and fixing the same in existing Y-shaped angle iron with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with GI stape and G.I. clips to retain horizontal, clips shall be @ 5 Nos per 2 spiral turns (approximate 126 clips per coil) including necessary bolts complete all as specified anddirected.Note: The weight of Concertina coilshall be ascertained by BOO as ordered by GE and payment shall be made accordingly and contractor shall have no claim on this account. |
| 20 | M&L for framed work such as grills , gratings etc with ends of bars shouldered and /or riveted or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters: walk ways , railings frame work of water tanks and similar work confirmingto Fe290, Gde E-165 complete all as specifiedand directed |
| 21 | M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 22 | M&L for preparationof newplastered/ concrete surfaces of wallsandapplying two coats of cement base paintover a coat of primer complete all asspecified andas directed. |
| 23 | Excavating in post holes each not exc 0.50 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc 25cm and removing surplus soil to a distance not exc 50m and making good surface all as specified`and directed . |
| 24 | M&L for plain cement concrete 1:2:4, type B-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed. |
| 25 | S&F structural steel work in tubular poles/trussesincluding special shaped washer etc complete using ERW or incuction butt welded tubes conforming to I.S. 1161-1998 grade St -240 complete all as specified and directed . |
| 26 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI basedcorrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed . |
| 27 | S&F Pre painted galvalume aluminium zinc coating (AZ-150 micron) GI basedplain steel sheet 0.5 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed . |
| 28 | Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLSH with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed medium grade conduit of suitable size with all accessories such as bend, reducers, MS hooks including modular galvanisedflush boxes of suitable size and white cover plate with frame as per relevant ISfor mounting modular switches, sockets, fan regulators etc including continuous earth wire of size 1.5 Sqmm PVC FRLSH stranded copper conductor unsheathed, insulated, strandedconnected to common earthpoint dolly for one light point/fan point/call bell point, 230 voltscontrolled by one switch complete all as specified and directed . Note:- Proper colour coding is to be followed as per IS specifications. |
| 29 | All as per srl item No 28 above but One 3 pin socket outlet 6 amp independentcomplete all as specifieds and directed |
| 30 | All as per srl item No 28 above but One 3 pin socket outlet 6 amp same board complete all as specifieds and directed |
| 31 | All as per srl item No 28 above but for one 3 pin socket outlet 16 Amp independent with cable of size 2.5 Sqmm for point wiring and 2.5 sqmm as in continuous earth wire. |
| 32 | S&F modular type switch, one way 6 Amps , 1 module complete all as specifieds and directed . |
| 33 | S&Fmodular type socket 3 pin, 6 Amps, 2 module complete all as specifieds and directed |
| 34 | S&F modular type switch, one way, 16 Amps, 1 module complete all as specifieds and directed . |
| 35 | S&Fmodular type socket 3 pin, 6 A/16 Amps,2 module complete all as specifieds and directed . |
| 36 | S&F Street light fitting, LED type, 35 Watt, 230V, ACwith high pressure die cast aluminium housing/body, heat resistantcomplete with driver, lamp holder, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, complete with IP 66 protection on andincluding bracket of 40mm dia,light grade,GI pipe , 1.20m complete with all accessories complete all as specified and directed. |
| 37 | S&F 5 mm thick acrylic LED light in english alhabetand logos to framing lighting sign board in colour on aluminium composite panel including wiring and necessary connections complete all as specified and directed. |
| 38 | S&F 5mm thick coloured aluminium composite panel , exterior gradefixed on mild steelframed structure including sealing of all joints using silicon sealant for installation of sign board letter complete all as specified and directed. |
| 39 | S&F MCB SPN,40-63 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 40 | S&F MCB Single pole, 6 to 32 Amp, 240 Volts withrupturing capacity 10 KA, \"C\" series, complete all as specifieds and directed . |
| 41 | S&FSheet metal enclosure for DBs,SPN, double door,IP-54 protected, 240 Volts,4 ways with 200 amps rated copper bus bar complete all as specified and directed |
| 42 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 corenominal cross section in service connection complete all as specified and directed. |