| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 3 | Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 4 | M&L for providing pain Cement Concrete(1:3:6) type C1 using 20mm graded stoneaggregate as in surface channel and drain complete all as specified and directed. |
| 5 | M&L for PCC type C1,1:3:6using 20mm graded crushed stone agg,in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 6 | M&L for extra for forming fair finished drain or channel 30 cm inner girth using extra cement including forms moulds, mitred/stopped ends etc complete all as specified. |
| 7 | Supply only polyester triangular fibres as secondary reinforcement in all types of concrete and mortars as approved by GE. |
| 8 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent) |
| 9 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 10 | M&L well burnt old size sub Class ‘B’ bricks, laidin trenches for cable protection complete all as specified and as directed by the Engineer-in-Charge. |
| 11 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specified and directed. |
| 12 | M&L for 75mm thick PCCtype C2,1:3:6 using 40mm graded stone aggregateas in sub base floorcomplete all as specified and directed. |
| 13 | M&L for 75mm thick PCCtype C1,1:3:6 using 20mm graded stone aggregateas in floor finishing the concrete surfaces even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L for Cement concrete tiles with grey cement and pigment of size 20cm x 20cm x 20mm thick,machine pressed; set jointed andpointed in neat cement slurry in floors, and cut and polished complete all as specified and directed. |
| 15 | M&L for screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6for laying floor finishescomplete all as specified and directed. |
| 16 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 17 | M&L for two coats of synthetic enamel paint over one coat of red oxideon new steel surfaces of any description over 10cm in width or girthincluding preparation of surfaces complete all as specified and directed. |
| 18 | M&L for 40mm dia GI pipe Light grade with all necessary fittings laid in trenches, fixed to wall/pole/under road/floor etc for cable protection complete all as specified and as directed. |
| 19 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 20 | Demolition of Concrete un- reinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 21 | M&L for 75mm thick PCC 1:3:6 type C1(Using 20mm graded stone aggregate) as in plinth protectionfinishedeven and smoothwithout using extra cement.Joints to be given at every 3m interval and corners of buildings and fitted with bituminious mastic or equivalent filler complete all as specified and directed. |
| 22 | M&L for 25mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregates)as in flooring, finished the surface even and rough completeall as specified and directed. |
| 23 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; completeall as specified and directed. |
| 24 | M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 26 | M&L forrendering 15 mm thick in two layers 10mm +5mm in cement mortar 1:4 on external surfaces of brick work or concrete surfaces andfinishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for 5mm thick rendering in cement mortar1:3 over/soffit of chajja/ceiling, finished surface even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L forrendering 10 mm thick in cement mortar 1:4 mixed with polyester triangular fibre at the rate of 0.25% by weight of cement on fair surfaces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed.Note :- Polyester triangular fibre shall be measured and paid separately under respective item of this schedule. |
| 29 | M&L preparation of new plastered surfaces of wall and applying two coat of cement base paint over a coat of cement wash complete all as specified and directed. |
| 30 | M&L for preparation of new surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 31 | M&L for preparation of old surfaces of OVER HEAD TANK by complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed.Note:- Rate for scafolding and connected materials upto 25 meter height shall deemed to be included in the quoted rates. |
| 32 | Removing & Hacking of existing concrete Carefully by low impact high frequency hammer OR by manual chipping without damaging the existing concrete or control sand blasting including cleaning the surfaces by air jet etc. completeNote:- Mode of measurement shall be per sqm of breaking area of concrete. |
| 33 | M&L for rusted metal (iron base) apply reebaklens RR of FOSROC or equivalent of SIKA/STP with brush for complete wetting of rusted metal surface of reinforcement and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions, specified and directed. |
| 34 | M&L for providing and and applying two coat of rust protector primer a two component epoxy zinc primer Nitozinc Primer Standard on property cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface complete allas per the manufactures specification and directed. |
| 35 | Supply and apply of two coat of acrylic polymer modified cementitious waterproof coating total thickness of 1mm polymer modified cementitious waterproof coating shall contain a liquid polymer component (Fosroc Nitocote CM210), which shall be as per manufacturer instructions and applied over prepared concrete surface, maintaining strictly the coverage specified by the manufacturer, complete all as specified and as directed. Notes:- (i) Surface to be free from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with smooth finish for application of waterproof coating and prime surface with water (ii) Typical properties of mixed material: Pot life at 20 C: 2 hours, Pot life at 35 C: 1 hour, colour: Grey or white, mixed density: 1950Kg/m3, Minimum application temperature 5 C, water permeability EN 12390 part 8: Nil, (Part 8) 2008 Negative pressure. Chloride ion penetrability as per: Low ASTMc 1202-03. |
| 36 | Supply and apply concrete surface with single component, fibre reinforced shrinkage compensated, polymer modified structural grade repair mortar like of FOSROC or equivalent of SIKA/STP at a thickness of 40mm. The repair mortar should have a minimum compressive strength 45 N/mm2, flexture strength 7 N/mm2 and tensile strength 2.5 N/mm2 at 28 days and tensile strength 7 N/mm2 complete all as per manufacturer instructions, specified and directed. |
| 37 | M&L for surface preparationfree from frost, surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish for applicaion of water proof coating prime the surface with water complete all as specified and directed. |
| 38 | M&L for waterproofing coating by providing and applying Fosroc Brushbond Roof Guard of FOSROC or equivalent of SIKA/STP , a single component High build fibre Reinforced Acrylic waterproofing render for roofing system applied by brush, at three coats at minimum dry film thickness of 1 mm, cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as per manufacturer specification, specified and directed.Solid Content - 70%, Tensile strength ASTM D 412-1.10 Mpa, Elongation ASTM D12-100%, Resistance to ageing due to - 1000hours, UV radiation ASTM D4587 E - No Change, Rapid Chloride Penetration ASTM c 1202 - Very low, Pull off adhesion ASTM D541 - 0.92 Mpa, Resistance to Algae growth ASTM D 5589-97 - Passes, Zero rating, Permeability (mm) (BSEN 12390 part 8) -n 5.0, Water vapour transmission (ASTM E 96) - 6.0g/m2 h |
| 39 | M&L for repairing of Cracks & Honeycomb Treatment by Injection Grouting by Identify the cracks and joints, shall be chased open into \"U\" groove shape.The surface of the groove shall be suitably prepared as require to apply the mortar. Apply Nitibond ofSBR Latex of Make Fosroc Nitobond or equivilant of SIKA/ STP and sealed with Shrinkage controlled, polymer modified, fiber reinforced cementitious repair mortar including fixing PVC nozzle up to required depth , injection grouting to be done with cement slurry admixed with expanding grout admixture cebex 100 of Make Fosroc Notobond or equivilant of SIKA/ STPto be mixed @ 225 gm per bag of cement complete all as specified and as directed . |
| 40 | M&L for bore packing to be done at pipe entries by forming properformwork and filling the gap with non-shrinkable cementitious grout conbextra GP2 of Make Fosroc or equivilant of SIKA/ STP and sealed with epoxy/polyester sealant complete all as specified and as directed . |
| 41 | M&L for sand cushioning for protection of underground cable, consolidatedand compacted with clean dry sand complete all as specified and directed. |
| 42 | M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 10Sqmm 2 core laid in trench/pole/on wall completer all as specified and directed. |
| 43 | M&L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 16Sqmm 04 core laid in trench/pole/on wall completer all as specified and directed. |
| 44 | M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 50Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed. |
| 45 | M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 95Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed. |
| 46 | M & L for XLPE insulated GI wire/Strip armoured Electric power cable (Heavy duty) with stranded Aluminium conductor 1100 Volts grade, cross sectional area 150Sqmm 3.5 core laid in trench/pole/on wall completer all as specified and as directed. |
| 47 | Dismantling cross-arms of M.S. channel orangle sections etc. complete and setting asidefor re-use with in 50m complete all as specified and directed. |
| 48 | Dismantling insulators any type, any size complete all as specified and directed. |
| 49 | Dismantling of ACSR or AAC conductor from service feeder or distributor span, complete all as specified and directed. |
| 50 | M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 51 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. |
| 52 | M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including good making for any surface etc complete all as specified and directed. |
| 53 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanisediron earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 54 | M&L for 20mm external dia Rigid non-metallicPVC conduit exclusiveof boxes (junction/ terminal) but inclusiveof all tees, bends, elbows, reducers, bellmouth tube ends andfixing accessoriessuch as couplers, locknuts,saddles, pipehooks etc.complete all as specified and directed. |
| 55 | Supply, laying & testing PVC insulated, PVC sheathed cable unarmoured, eletric control cables (Heavy duty) with standered copper conductor of size 6qmm, 4 core, 1100 volts grade. complete all as specified and directed. |
| 56 | Supply and fixing in repair digital auto level controller including top mounted, non contact ulrasonic level i.e sensing range upto 5 mtrs water level transmitter (probe unit), level indicating controlling box including sustem incorporated digital stage level, high & low alarm, pump automation etc complete all assensing range upto 5 mtrs water level sensor for overhead water tank complete all as specified and directed. Make :- RAMCO model No-ALC MK-I or as approved by GE |
| 57 | M&L for 3 core cable 2.5sqmm of copper conductor, PVC insulated & PVC sheathed multicore round flexible industrial cableweather proof in existing surface/ recessed/on rack etc. including PVC conduit medium grade 25mm dia complete all as specified and directed |
| 58 | Supply, Jointing and laying double wall corrugated (DWC) pipes of size 63mm outer dia and 50mm inner dia made of high density polythyline (HDPE) conforming to IS 16205 (part-24) including all accessories i.e. all type of joints, sockets, elbows, bends, end caps etc complete all as specfied and directed. |
| 59 | Supply and fixing LED Twin Aviation light/Obstruction light IP-65, 240 volts installes on the roof of overhead reservoir complete including taking down old onecomplete all as specfied and directed. Make :- Philips/Bajaj/Havells/CG |
| 60 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts Indoor type LT panel board confirming to IP 65, CPRI type tested, factory fabricated &factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penalmade out of suitable size angle iron, channel and fabricated from 2.00 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & includingbusbars made of pure copperduly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shall be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitableearth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the panel board in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with 2.5 Sqmm single core multistranded copper condutor FRLSwire with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply.:- Incoming:- (a) Aluminium bus bar - 300 Amps rating - 04 Nos. for phases and neutral.(b) MCCB 4 pole200 amp, 36 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 01 No. Make Schnieder Cat NoLV525342, Legrand cat No 420248, Siemens3VA1220-4GE42-0AA0, ABB-1SDA068109R1. (c)Digital type flush mounted 3 phase VAF + PF meter with input voltage measurement range 50-500VAC (P-P), Aux supply 30-300 Volt AC/DC, CT secondary site selectable 1-5A, Accuracy Cl-1-0.5.(d) RYBLED type indication lampSet ofthree- 01 No.Out going:-(a) MCCB 4 pole 63 Amp, 25 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 03 Nos. Make Schnieder Cat No LV 510315, Legrand cat No 420053, Siemens 3VA 1163-3GE42-0AA0, ABB-1SDA067404R1.(b) Star delta Starter 415 volts 3 phase of capacity 20 HP with Coil Voltage 415 Volt, relay range 13-21 Amp and i protector ( iVDSM) - 03 Nos |
| 61 | Supply, installation, testing and commissioning 3 phase and neutral, 415 volts Indoor type LT panel board confirming to IP 65, CPRI type tested, factory fabricated &factroy assembled , waterproof,dust and vermin proof cubical type with locking arrangement , LT Penalmade out of suitable size angle iron, channel and fabricated from 2.00 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), independently housing for each control switch gear and indicating lamps with & includingbusbars made of pure copperduly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shall be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for cable gland and lugs for incoming and out going cable and connecting suitableearth strips .Suitable openable doors shall be provided of all operational switchgear and MCCBs and detchable cover shall be provided on all other accessories. Grouting the panel board in ground with & including suitable size foundation & plinth of PCC 1:3:6(type C-1 using 20 mm grade stone aggregate) complete.Penal shall be manufactured suitable for housing and including the following duly control wiring with 2.5 sqmm single coremultistranded copper condutor FRLSwire with colour coding incl connection with copper lugs complete for 3 phase 50 Hz electric supply.:- Incoming:- (a) Aluminium bus bar - 400 Amps rating - 04 Nos. for phases and neutral.(b) MCCB 4 pole 320 Amps, 36 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 03 Nos. Make Schnieder Cat No LV 540308, Legrand cat No 422006, Siemens 3VA 1332- 4GE42-0AA0, ABB-1SDA 054477R1. (c) Onload changeover switch 4 pole 315 amps, 415 volt, 4 pole- 02 Nos(d)Digital type flush mounted 3 phase VAF + PF meter with input voltage measurement range 50-500VAC (P-P), Aux supply 80-300 Volt AC/DC, site selectable CT secondary 1-5A, Accuracy Cl-1-0.5.(e) RYBLED type indication lampSet ofthree- 01 Nos.Out going:- (a) MCCB 4 pole 200 Amp, 36 KA, 415 volt, 100% Icu, adjustable thermal magnetic protection(O/L & S/C protection) - 03 Nos. Make Schnieder Cat No LV525342, Legrand cat No 420248, Siemens 3VA1220-4GE42-0AA0, ABB-1SDA068109R1. |
| 62 | Taking down of aluminium/GI strip of any size and for reuse of serviceable complete all as specified and directed. |
| 63 | (Note : The Scope of Work contained in \"Sch of Credit\" amounting to Rs. 25,910.00 (refer Tender Srl Page No 26). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’ |