| 1 | Carring out petty repairs to security light system complaint attending street light/flood light/highmast light/ perimeter lights in technical and domestic area including TRU,WSA and indorabagh on daily basis with suitable tools and machinary checking U/S cable complete circuit/lights, rectifying defects and replacement of unserviceable parts including insulation tap, minor wires cable for internal connection , lugs etc, tightening of junction box in pole from 0900 to 2000 hrs all as specified and directed. (i)All safety tools shall be provided to electrician. (ii) Addequte Electrician with helper(minimum 01 Nos) should be well qualified and experienced. . (iii) Ladder/ convence any cycles shall be provided to employed person(v)NO android phone shall be permitted inside Technical area.(vi) Excavation, taking out cable, relaying of cable shall be paid seperately under respective of items.vii) The required spare parts will be measured and paid seperatly |
| 2 | Supply only street light bracket, clamps, nuts and boltmade out of 40 mm dia light grade GI pipe(length of pipe should not be lessthan 1.2 mtrs) , two set of clamp made out of 25 mm x 3 mm flat iron, nuts & bolts as required , bend to shape andfixing arrangement complete all as specified and directed. |
| 3 | Supply only Street light fitting with new generation energy saving environemental friendly long life LED street light made up of pressure die cast aluminium housingwith lens, energy efficient high quality consistency, glare control with toughned glass and individual high power LEDs with secondary optics ,IP 66 protection and impact of capacity 50 Watt complete all as specified and directed. Make:- Philips / Bajaj/ L&T/ CG / Havells. |
| 4 | Supply only flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66LED flood light with high power LEDs as light source of capacity 50 Watt complete all as specified and directed. Make:- Philips / Bajaj/ L&T/ CG / Havells. |
| 5 | Supply only flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66LED flood light with high power LEDs as light source of capacity 100 Watt complete all as specified and directed. Make:-Philips / Bajaj/ L&T/ CG / Havells. |
| 6 | Supply only flood light fitting with new generation energy saving environement friendly long life exclusive innovative die cast aluminium IP66LED flood light with high power LEDs as light source of capacity 200 Watt complete all as specified and directed. Make:-Philips / Bajaj/ L&T/ CG / Havells. |
| 7 | Supply only LED light driver suitable for existing LED Street light fitting of capacity up to 90 Watt complete all as specified and directed. Make :- Havells/Philips/Syska/Bajaj. |
| 8 | Supply only LED light driver suitable for existing LED Flood light fitting of capacity upto 250 watt complete all as specified and directed. Make :- Havells/Bajaj/Philips/Syska. |
| 9 | Supply only cable junction boxwith newpole mounted thermoplastic cable junction box for steet light 4.5 modulewith IP-65 protection, halogen free and weather proof with metric knockouts for cable entryfor outdoor installation of approx size 155 mm x 210mm x 92 mm with front door opening system including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 3 to 6 Amp 240V AC with mounting clamp of flat iron, nut, bolt and washers complete all as specified and directed .Make of junction box -Hensel / Syntex / Havells/ Legrand/ Hager. |
| 10 | Supply and fix MCB 4 pole 100Amps, 240 Volts 50 HZ, 10 KA breaking capacity, \"C\" curve complete all as directed.Make:- Havells/L&T/Legrand/ABB/ Hager. |
| 11 | Supply and fix Power contactor with new power contactor4 pole AC, with 415 volt coil, 40 Amp rating complete all as specified and directed. Make-L&T/Havells/Legrand / Hager. |
| 12 | Supply and fix aviation light fitting with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure capacity 20 Watt complete all as specified and directed by Engineer-in-charge. Make:Philips/Havells/Syska/ L&T. |
| 13 | Taking out unserviceable LT cable of any size from trenches/duct etc carefully including bricks and keeping in safe custody either for relaying or disposalcomplete all as specified and directed |
| 14 | Supply, laying jointing and testing16 Sqmm 4 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and directed. Make - Havells/Polycab/Finolex/ Plaza |
| 15 | Supply, laying jointing and testing25 Sqmm 4 core XLPE insulated LT under ground cable, 1100 volts grade heavy duty, armoured with multi stranded aluminium conductor laid in trenches/ ducts pipes or on poles etc complete all as specified and as directed.Make - Havells/Polycab/Finolex/ Plaza |
| 16 | Re- laying ,passing through pipe , connecting and testingUG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100volts grade (Note:- Excavation , Earth Work pipe etc will be measured and paid sepretaly)XLPE Cable ofsize 16 Sqmm complete all as specified and directed. |
| 17 | Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc complete all as sepecified and directed. |
| 18 | Returning filling in, soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and directed. |
| 19 | Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point. Complete all as specified and directed. |
| 20 | M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed.(Note:- punned thickness shall be measuredonly) |
| 21 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 22 | M & L for boring of holes under road, pavement, hard standing by trenchless boring manually or by machine for insertion ofGIpipe of size upto 40 mm dia suitable complete all as specified and directed. |
| 23 | S&F GI pipe 40 mmlight grade with all fitting fixed to electric pole and laid in road crossingfor cable protection with suitable size clamp, nut bolt and washers all as directed. Make : Tata/Jindal/swastik |
| 24 | S & F in repair service connection 1100 volts grade heavy duty cable PVC insulated copper conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 2.5 Sqmm 2 core complete all as specified and directed. Make :-Palza/Polycab/Havells/Finolex |
| 25 | M&L for painting of existing LT/HTpole upto 9 / 11meter heightwith twocoat of aluminium paint complete including preparation of old painted surfaces and including makingblue / black colour paintstrip of 15 cm width including writing the Pole Nos.complete all as specified and directed. |
| 26 | S&F in Photonic Astronomical timer switches (Having Latitude and Longitude at the installed location of Indian cities in memory) 150V to 260V AC, 50 HZ single phase of 15000 watts rating with dual mode operation (Asronomical timer/Real time clock) , location accuracy + 1 degree, clock accuracy +1 second and provided to delay \"Switch ON\" Lights after sunset PFF offset provided to early \"Switch OFF\" lights before sunrise time, RTC mode input ON and OFF time clock based with on delay 0-99 seconds user adjustable and dual relay can be individually programmed with control MCB and auto/manual switch, 4 pole contactor complete with steel encosure duly painted and fixing MS clamps for mounted on polecomplete all as specified & directed. Make:-L&T Seimeus/ Legrand/ C&S. |
| 27 | S&F in XLPE insulated sheathed(heavy duty) armoured aluminium conductor cableof size 6.0 Sqmm, 2 core for connection drawing through pole or GI brackets of street light fittings with junction box complete all as specified and directed.Make : Plaza/Finolex/Havells/Polycab. |
| 28 | M&L for heat shrinkable straight through jointing kit of 1.1 KV grade 25 Sqmm to 50 Sqmm x 3.5 core XLPE cable including suitable size of connectorcomplete all as per directed by Engr-in-charge. including necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault locationall as specified and directed. MAKE:- M-seal / Raychem / Denson. |
| 29 | Detection of pin point fault in LT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified anddirected. Notes-(1) Cable fault locating machine to be arranged at site with in 12 hrs after intimation(2) Earth work will be measured seperatly.(3) Cost of transpotation in unit rate is deemed to be included. Location:-AF stn BKT. |
| 30 | Cutting and trimming of tree branches/ pushes 2 mtr all around of single pole any size obstructing lumination of street light pole removing trimmed tree branches and bushes. Complete all as specified and directed. |