| 1 | Taking down dismantling / Servicing/ Attending of Breakdown Complaints with Rectification ofWT/ Split type/ Casset typeAir Conditioner, Refrigerator, water coolers of any capacity & \"make\", opening up for Servicing/ Maintenance , inspection / examination for serviceability of compressor, fan, motor, relays,PCB of indoor and outdoor units, capacitors,lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips, unserviceable wiring, rubber mounting for compressor including all minor spare parts for carrying out servicing including reassembling & testing of AC, Refrigerator & water cooler complete all as directed NOTE:- (i) All the Major Spare parts used in course of rectifying the complaints and breakdowns will be measured and paid separately in concerned seduled items.. (ii) For Lubrication of moveable parts, replacement of worn out bolts , screws, rubber gaskets, seals, terminal & link clips,wires and insulation tapesincluding cotton wastes with other minor items are included in unit rates.(iii) The Breakdown Complaints should be addressed by the Contractor\"s Mechanic or representatives within 4-8 hours , for delay of 24 hours for attending of User\"s complains would be charged Rs.1000.00 ( One thousand only) as token of Penalty. |
| 2 | Supply and charging of Refrigerant gas R-22 (Mafron) for Window type/ Split type AC of various capacity after leak test, Make :- Mafron/Floron. |
| 3 | Supply and charging of Refrigerant gas R-32 (Mafron) for Window type/ Split type AC of various capacity after leak test,Make :- Mafron/Floron. |
| 4 | Supply and charges of R-134a gas for water cooler of any capacity after leak test,Make :- Mafron/Floron.. |
| 5 | Supply and charges of R-410 gas for Split AC of various capacity after leak test,Make :- Mafron/Floron. |
| 6 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 2.5 MFD, + 5% for fan motor of water cooler and airconditioners. Make: TIBCON/SARDA/UNIVERSAL |
| 7 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 1.5 MFD, + 5% for fan motor of water cooler and airconditioners.Make: TIBCON/SARDA/UNIVERSAL |
| 8 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 4 MFD, + 5%for fan motor of water cooler and airconditioners .Make: TIBCON/SARDA/UNIVERSAL |
| 9 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 6 MFD, + 5% for Split type airconditioners Outdoor Fan motors..Make: TIBCON/SARDA/UNIVERSAL |
| 10 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 8 MFD,+ 5%, 4 pin for Splittype airconditioners.Make: TIBCON/SARDA/UNIVERSAL |
| 11 | S&F, in replacement, capacitor 230/440 VAC, 50 Hz, 10 MFD,+ 5%, 4 pin for Water Coolers.Make: TIBCON/SARDA/UNIVERSAL |
| 12 | S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 35+6 MFD, + 5%, 7 pin for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL |
| 13 | S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 50 MFD, + 5%, 7 pin PSC system for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL |
| 14 | S&F, in replacement, burst proof series dual capacitor 230/440 VAC, 50 Hz, 50+6 MFD, + 5%, 7 pin PSC system for Airconditioners.Make: TIBCON/SARDA/UNIVERSAL |
| 15 | Supply and replacement of Single phase Power contactor ,20 Amps,50Hz , 230 volts for Split Ac of 2TR capacity with taking down old one.Make:L&T /Legrand/HPL) |
| 16 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type ACof 1.5 TR capacityall as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 17 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type ACof 2.0 TR capacityall as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 18 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type ACof 1.5 TR capacityall as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 19 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type ACof 2.0 TR capacityall as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 20 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type ACof 1.5 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 21 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Indoor Units of Split type ACof 2.0 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 22 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type ACof 1.5 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 23 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Outdoor Units of Split type ACof 2.0 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 24 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Indoor Units of Cassette type ACof 1.5/2.0 TR capacity all as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 25 | Supply and replacement of printedcircuit board (PCB) with display board,sensor and remote control for Outdoor Units of Cassette type ACof 1.5/2.0 TR capacity (Inverator Model, 5 Star ) all as per existing type and make including taking down. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 26 | Supply and replacement of printedcircuit board (PCB) Reactor ofSplit type AC(Inverter Model) of 1.5/2.0 TR capacity, 5 Star ) all as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 27 | Supply and replacement of Air Filter Sensor motor ofSplit type AC(Inverter Model) of 1.5/2.0 TR capacity, 5 Starall as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 28 | Supply and replacement of Swing motor of Split type ACof 1.5 TR/2.0 TR capacity of STAC of without Inverter model STAC all as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 29 | Supply and replacement of Swing motor of Split type ACof 1.5 TR/2.0 TR capacity of STAC ofInverter model STAC all as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 30 | Supply and replacement of Drain Pumpmotor of Cassettype ACof 2.0 TR/3.0 TR capacity ofInverter modelall as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 31 | Supply and replacement Sensor Unit of Drain Pumpmotor of Cassettype ACof 2.0 TR/3.0 TR capacity ofInverter modelall as per existing type and make including taking down.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 32 | S&F, in replacement, of Remote Control hand set with suitable capacity Battery suitable forcapacity of 1.5/2.0 TR(As per sample) of STAC/ Cassette AC all as specified and directed(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 33 | Taking down old Unserviceable Printedcircuit board (PCB) with display board,sensor and remote control including all connected accessories of Indoor Units of Split type ACof any make and capacity of 1.5 TR/2.0 TR and send to reputed / authorised Company Workshop for necessary repairs with replacement ofSpares for functionable and refix the same in its own position and testing all as per existing type and make. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung).NOTE :- The Cost of Transportation and Spare parts used in repair are deemed to be included in Unit rates. |
| 34 | Taking down old Unserviceable Printedcircuit board (PCB) with display board,sensor and remote control including all connected accessories of Indoor Units of Split type AC/ Casset AC of any make and capacity of 1.5 TR/2.0/3.0 TR(Inverator Model, 5 Star ) and send to reputed / authorised Company Workshop for necessary repairs with replacement ofSpares for functionable and refix the same in its own position and testing all as per existing type and make.(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung).NOTE :- The Cost of Transportation and Spare parts used in repair are deemed to be included in Unit rates. |
| 35 | Taking down old Unserviceable Printedcircuit board (PCB) with display board,sensor and remote control including all connected accessories of Outdoor Units of Split type AC/ Casset type AC of any make and capacity of 1.5 TR/2.0/3.0 TR(Inverator Model, 5 Star ) and send to reputed / authorised Company Workshop for necessary repairs with replacement ofSpares for functionable and refix the same in its own position and testing all as per existing type and make. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung).NOTE :- The Cost of Transportation and Spare parts used in repair are deemed to be included in Unit rates. |
| 36 | Supply and fix, in replacement, Fin and Tubes type air cooled condenser Unit for STAC / Casset type AC of capacity 1.5/2.0 /3.0 TR with copper tubing of size 1/4\" as per sample. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). . |
| 37 | S&F, in replacement, polystyrene soft thermocol, clear and rather brittle quality required at site during installation of Split type air conditioners of size : 180cm x 90cm x 40mm. |
| 38 | S&F, in replacement, Brass serviceValve of Liquid linesuitable for Split type ACcondensing unit of size 1/4\"dia of any make and type of STAC all as specified and directed. |
| 39 | S&F, in replacement, Suctionservice line Valve suitable for Split type ACcondensing unit of size 5/8\"of any make and type of STAC all as specified and directed. |
| 40 | S&F, in replacement, fan blade assembly made of aluminium alloy complete for out door unit of split type/ Casset type AC. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 41 | S&F, in replacement, PVC fan blade suitable for water cooler of any capacity and size.(Make Same as of existing WC /Bluestar / Usha/ Voltas). |
| 42 | S&F, in replacement, PVC blower suitable for any make/ modelof Indoor unit of Splittype air conditioner of cap 1.5 TRas required and directed. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 43 | S&F, in replacement, PVC blower suitable for any make/ modelof Indoor unit of Splittype/ Casset typeAir conditioner of cap2.0/3.0 TR as required and directed. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 44 | Supply andreplacement of synthetic thermal insulation pipe with binding tape of 3/8\" dia suitable for suction copper pipe ofSplit type AC complete all as directed including taking out old deterioted pipe and burried in ground. |
| 45 | All Same as above item No-44 but of dia 5/8\"suitable for discharge/liquid line ofSplit type AC/ Casset type AC. |
| 46 | All Same as above item No-44 but of dia 1/2\"suitable for discharge/liquid line of Split type AC/Casset type AC. |
| 47 | Supply and Replacement of internal wirings with single core FRLSH, copper conductor of size 1.5 sq.mm with taking down of old unserviceable wirings of STAC. |
| 48 | Supply and Replacement of internal wirings with single core FRLSH copper conductor of sizes2.5 sq.mm with taking down of old unserviceable wirings of STAC. |
| 49 | Supply and Replacement of elect cable of size 2.5 sqmm 3-core FR copper conductor circular type with taking down of old unserviceable incoming cables of STAC. |
| 50 | Supply and replacement of Defrost PVC water drain pipes of size 20 mm dia for split type AC including taking down deterioted pipe and burried in ground. |
| 51 | S&F corrugated PVC flexible drain pipe of out let of water cooler, size 36 mm inner dia of standard length including taking down old deterioted pipe and burried in ground. |
| 52 | Supply & Fix, in replacement, Hose clamps suitable for holding of 36 mm dia pipes. |
| 53 | Supply & Fix, in replacement of Hose clamps suitable for holding of 20 mm dia pipes. |
| 54 | Supply and replacement of Rubber bush suitable for holding of Blower motor of LG/HITACHI |
| 55 | Supply and replacement of Clamp sets for the bush of STAC(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 56 | Supply and replacement of Clips ( steel )suitable for holding of Blower motor and fan blade of STAC(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung). |
| 57 | Supply and replacement of Rubber bush suitable for holding of condensing fan motor of water cooler of any size and capacity. |
| 58 | Supply and replacement of Clamp sets for the bush ofwater cooler of any size and capacity. |
| 59 | Supply and replacement of hermeticallysealed Rotarytype compressorof 1.5 TRcapacity for splittype AC of existing make andmodel with new compressors and assemblingtesting the same with replacement of necessary drier and capillary tube complete all as directed by Engineer-in-Charge including taking down old U/S Compressor all as specified and directed.. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung/Kirloskar/Hitachi+E87) |
| 60 | All as same here and beforeas above item No-59 but2.0 TRSplit type/ Casset type Room Air Conditioner compressor including taking down old U/S Compressor all as specified and directed... (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung/Kirloskar/Hitachi+E87) |
| 61 | All as same here and beforeas above item No-59 butreciprocating typeSplit type Room Air Conditioner compressor of 1.5 TR capacity including taking down old U/S Compressor all as specified and directed... (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung/Kirloskar/Hitachi+E87) |
| 62 | All as same here and beforeas above item No-59 butreciprocating type Split type Room Air Conditioner compressor of 2.0 TR capacity including taking down old U/S Compressor all as specified and directed...(Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung/Kirloskar/Hitachi+E87) |
| 63 | Supply and replacement of compressorfor water cooler40/80 to 120/150Ltrs capacity and assembling and testing the compressor unit completeincluding taking down old U/S Compressor all as specified and directed.. (Make : DANFOS/ LG/ Kirloskar |
| 64 | Supply and Replace hermetically sealedreciprocating type compressorfor Refrigerator 310 Ltr capacity including taking down old U/S Compressor all as specified and directed...(Make Same as of existing WC /Bluestar / Usha/ Voltas/Danfos/ Indfos/ LG ) |
| 65 | Supply and Replace hermetically sealedreciprocating type compressorfor Deep Freezer of capacity300 to 500Ltr capacity including taking down old U/S Compressor all as specified and directed..(Make Same as of existing WC /Bluestar / Usha/ Voltas/Danfos/ Indfos/ LG ) |
| 66 | Repair to worn out body of STAC of any make & capacity by replacing worn out portion by providing new CRCA flat sheet / MS angle or strip of appropriate gaugeas per existing and fabricated to the shape as required including necessary welding, filling of putty, grinding to make the jointed surface even and apply two coats of synthetic paint over one coat of red oxide all as directed and specified including taking down. |
| 67 | Repair to body of water cooler by providing MS sheet 2 mm thick including welding, replacement of wornout nuts & bolts and repair/fabrication of the compressor mounting base as per existing fabrication work including all as directed and specified ( Approx area of MS Sheet 0.75 Sqm) and painted by two coats of synthetic enameled paint of existing cooler over a coat of red oxide primer. |
| 68 | Taking outCondensing Fanmotor of Split type AC of 1.5 TR capacity from its existing base and dismantling the same and rewinding the burnt out winding with super enameled copper conductor with existing gauge and size of conductor and varnishing all insulating materials including making necessary heat treatment complete all as directed by Engineer-in-charge. |
| 69 | All as same here and beforeas above item No-68 butof condensing fan motor of split type AC of 2.0/3.0 TR capacity. (Make Same as of existing AC / Kirloskar/GE/ Crompton Greaves) |
| 70 | All as same here and beforeas above item No-68 butof Blower motor of Split type AC of 1.5/ 2.0/3.0 TR/ Condensing fan motor of Water Cooler of 40/80 ltrs capacity.(Make Same as of existing AC & WC / Kirloskar/GE/ Crompton Greaves or equivalent as approved) |
| 71 | Supply and replacement of unserviceable Fan motorof condensing Unitof STACwith newmotor suitable forSTAC of 1.5 TR capacity as per existing suitable capacity including taking down old one.(Make Same as of existing AC / Kirloskar/GE/ Crompton Greaves or equivalent as approved) |
| 72 | Supply and replacement of unserviceable Fan motorof condensing Unitof STACwith newmotor suitable forSTAC of 2.0 TR capacityas per existing suitable capacity including taking down old one. Make Same as of existing AC / Kirloskar/GE/ Crompton Greaves or equivalent as approved) |
| 73 | Supply and replacement of unserviceableBlower motor of indoor unit of split AC of 1.5/2.0 TR / Ccondensing fan motor of Water cooler with newmotor ofsplittype AC/ Water coolerof any make and capacity as per existing suitable capacity including taking down old one..(Make Same as of existing AC & WC / Kirloskar/GE/ Crompton Greaves or equivalent as approved) |
| 74 | Periodical Servicing / Maintenance of WT AC/SplitAC/ Casset type AC of 1.5 / 2.0/3.0 TR capacity and carried out the necessary Servicing/ Maintainance and thenpainting externally withone coat of synthetic enamel paint of existing shade and approved make after cleaning/washingthe external surfaces,internal housings,Fins of Evaporator and Condenser by using Compressed Air and water with replacement of Tored and and damaged Air filtersand assembling, testing completeall as directedand specificationby Engineer-in-Charge. |
| 75 | Dismantlingthe voltage stabilizerof anycapacity ( 1 to 5 KVA) andmake, opening up forinspection/checking serviceability of voltage regulatingtransformer relays, circuitboard, voltmeters,incoming/outgoingconnections etcand reassembling the same with dismantledcomponentafterreplacement of burntspare parts andinternalwiringcompleteall as directed and specified by Engineer-in-Charge.Note.Replacement of spare parts shall be measured and paid separately under items below :- |
| 76 | Supply only transformer of any capacity between 4 to 5 KVA including taking down all as specified and directed |
| 77 | Supply only transformer of any capacity between 1to 3 KVA including taking down all as specified and directed |
| 78 | Supply only square/ round type voltmeter of size 2\" x 2\" for various voltage stabilizers including taking down all as specified and directed |
| 79 | Supply only transformer relay for various capacity of stabilizers including taking down. |
| 80 | Supply only circuit board for various capacity of stabilizer including taking down. |
| 81 | Supply only 3 way connector for voltage stabilizer including traking down |
| 82 | Supplyand replacement ofPTMT float valve of 15mm size suitable for water cooler of cap 40/80 ltr/hr capacity including taking down old float valve.(Make Same as of existing WC /Bluestar / Usha/ Voltas/ Prayag or equivalent as approved by GE.. |
| 83 | Supply and replace push type water tap made of stainless steel chrome plated suitable for 40/80 Ltr capacity water cooler as per existing including taking down.(Make Same as of existing WC /Bluestar / Usha/ Voltas/ Prayag or equivalent as approved by GE.. |
| 84 | S&F, in replacement, PVC connection pipe with both end Brass adaptor of 15 mm dia for Water cooler(Make Same as of existing WC /Bluestar / Usha/ Voltas/ Prayag or equivalent as approved by GE.. |
| 85 | Replacement of rusted and damaged bracket / Base Stand with new one for holding of STAC at the rear side as a platform made up of MS Plate and grouted on the wall with 04 Nos MS Anchor bolts and washersall as directed and specified including taking down old unserviceable Brackets. (Make Same as of existing AC / LG / Hitachi/ Videocon/Samsung or equivalent Approved by GE ) |
| 86 | S&F in replacement, of Battery for Remote Control hand set with suitable capacity(As per sample) of STAC/ Cassette AC all as specified and directed ( Make : Eveready/Nippo) |