| 1 | S&F in repair15watt LED post top made in die- cast aluminium with innovative glare free indirect lighting distribution and IP-65 protection including necessary earthwork andPCC work for for fixing of post and nuts, bolts with necessary connection etc complete all as specified and as directed. Make:- Havells,Cat No RUBYMINIPT15WLED830PSYMTOPC / Philips / crompton/Bajaj.Note: Contractor have to write date of changing in bold letter using permanent marker and submit minimumtwo years manufacturer warrantee certificate with purchase voucher on completion of work. |
| 2 | S & F in repairs, signboard of RO Plant Sign Board made out of Stainless Steel of 50x50mm square tube(Sign Board Size3\"x2\") with 2.5m both sideof 50mm dia stainless steel with transparent PVC acrylic sheet of thickness 2.5mm of colour as directed with letters and digits of approx size 8x8CM(Appx 50Nos) complete all as specified and as directed. |
| 3 | S & F in repairs, looping box of size 130mmx130mmx77mm weather proof IP 66/67 including connector blocks four way having suitable size of bolt to connect upto 6sqmmx2core cable two nos with help of suitable gland, thimble nuts, washers supports by flat aluminium clamps not less than 25mmx3mm with suitable size of nuts, bolts,and washers inside and outside looping box including fixing with electric pole complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depthfor laying cables, foundation for pole, etcand getting out in hard/dense soil complete all as specified and as directed. |
| 5 | All as per item No 4 here in before but depth exceeding 1.5 m and not exceeding 3.00 m. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming of soil in layers n. exc 25cm thick complete all as specified and as directed. |
| 7 | Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. |
| 8 | Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose) |
| 9 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable complete all as specified and as directed. |
| 10 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable complete all as specified and as directed. |
| 11 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 4 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable complete all as specified and as directed. |
| 12 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 6 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable complete all as specified and as directed. |
| 13 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including taking out old cable complete all as specified and as directed. |
| 14 | S&F 1100 volts grade heavy duty flat cable ofsize 6 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 15 | S&F 1100 volts grade heavy duty flat cable ofsize 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 16 | S&F 1100 volts grade heavy duty flat cable ofsize 16 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed. |
| 17 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed. |
| 18 | M&L forerection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundationduly painted painted with two coats of Aluminium paint over a coat of red oxide primer with 30 cm of black,yellow and white paint upto 1.2m including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed. |
| 19 | M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 20 | M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 21 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping for the new/existingSteel Poles, cills,includingnecessary formwork (straight or curved) complete all as specified and as directed. |
| 22 | M&L for GI pipe light grade 40mm bore with all fittings laid in trenches/walls/ floor/ poles/ road crossingincluding taking up/ down old pipecomplete all as speciffied and as directed |
| 23 | M&L for GI pipe light grade 50mm bore with all fittings laid in trenches/walls/ floor/ poles/ road crossingincluding taking up/ down old pipecomplete all as speciffied and as directed |
| 24 | S & F in repairs, LED street light of capacity 45 Watt made up of pressure die cast aluminium housing withhigh power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10kV including minimum 1.5m service cable 4sqmm 2 core complete all as specified and as directed. Note: Contractor have to write date of changing in bold letter using permanent marker and submit minimumtwo years manufacturer warrantee certificate with purchase voucher on completion of work. |
| 25 | S & F in repairs, LED street light of capacity 60 Watt made up of pressure die cast aluminium housing withhigh power LED as light source and lens embedded PC cover including electronic driver should have luminaries efficacy ≥110 lumens/watt, CRI>70 ,PF > 0.95,CCT≥5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10kV including minimum 1.5m service cable 4sqmm 2 core complete all as specified and as directed. Note: Contractor have to write date of changing in bold letter using permanent marker and submit minimumtwo years manufacturer warrantee certificate with purchase voucher on completion of work. |
| 26 | M&L forlight bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 1.20 metre including taking out old bracket of any description complete all as specified and as directed. |
| 27 | M & L for Prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto a distance of 150m, each span not exceeding 45 m complete all as specified and as directed. |