| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 2 | M&L for Autoclaved aerated concrete (AAC blocks)for masonry fixed with Ready Mix Jointing Mortar complete all as specied and as directed Makes/brands of Ready Mix Jointing Mortar shall be “Speed Dry Mix”/ “DUBOND”/ “MAGIC BOND”/ BUILDWELL”. Makes/manufacturers of AAC blocks :AEROCON/Ecolite/ISI marked Grade I as approved by GE |
| 3 | M&L for brick work with fly ash old size bricks, straight or curved on plan n.exc 6m mean radius, built in cm 1:6 complete all as specified and directed. |
| 4 | M & L for except brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius with old size bricks in CM 1:6 complete all as specified and directed. |
| 5 | M & L for walling of random rubble uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | All as per sr. item No.5 above but except stone |
| 7 | Extrafor hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to random rubble walling,uncoursed orbrought upto courses |
| 8 | Taking down cement mortar plastering on brick or stone walls, etc. including raking out joints,hacking for key,scrubbing down with water, etc. |
| 9 | M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto coursein CM 1:4 all as specified. |
| 10 | M & L for provide 10mm thick internal plaster with ready mix plaster onAAC block/Brick Masonry (Makes/brand- ACC’s “ACCOPLAST”/ CK Birla’s “AEROCEN” / Magic Plast /Speed Dry Mix’s “ ECO PLASTER”complete all as specified and directed |
| 11 | M&L for preparation of surface of wall and applying two coat of exterior weather proof (on putty surface)100% anti fungal acrylic smooth emulsion with silicon additives that offer anti alge high performance exterior wall finish with 5 years of performance warranty by manufacturer applied by using Airless spray technology with max working pressure of 3300 PPSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper, should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. Make: Asian (apex ultima), Berger (wather coat), nerolac (excel total) |
| 12 | Dismantling of posts or struts(wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed groundall as specified anddirected. |
| 13 | Dismantling of fencing wire mesh of any type complete all asspecified and directed. |
| 14 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil. |
| 15 | M & L for cement concrete Type B2 1:4:8using40 mm graded stone aggregatein foundations, filling and mass concrete complete all as specified. |
| 16 | S & F in repairs galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified anddirected. (Each line wire to be measured) |
| 17 | M & L for RCC 1:2:4, type B-1, (using 20mm graded stone aggregates) as in precast fencing posts, stuts etc area exc 100 & not exc 250Sqcm including form work etc completeall as specified:- (Reinforcement shall be measured and paid seperately.) |
| 18 | S&F 10mm dia MS Round bars as in support of Chain Link Fencing all as specified. |
| 19 | Supply only chain link MS galvanized fencing of any size or type complete all as specified anddirected. |
| 20 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire |
| 21 | S & F mild steelbolt screwed one end with hexagonal or square nuts & washers the other end enlarged not exc 15cm long dia of neck 12mm complete all as specified anddirected. |
| 22 | M&L for Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk forbalusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 all as specified anddirected. |
| 23 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 24 | M&L for Providing, cement concrete type B1 1:2:4 using (20mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses,parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all complete all as specified and directed |
| 25 | M&L for cement concrete type B0 (1:2:4) using 20 mm graded stone aggregate as in surface channels and drains complete all as specified anddirected. |
| 26 | Demolition of cement concrete (unreinforced) in any description and in any position complete all as specified anddirected. |
| 27 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for .Note- Rate includes for reinforcement cutting as required to facilitate demolition. |
| 28 | M&L for providing RCC (1:2:4) using 20mm graded stone aggregate as in coping, slab supported on wall, beam, lintels etc complete all as directed by Engrin charge. |
| 29 | M & L for Providing high prestress precast ce- ment concrete Type M-25 in columns, posts, boundary pillars, with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in cementmortar 1:6 complete with joints to match as directed by Engr in charge.(Note: The quoted rate shall be inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm reinforcement , Form work)MAKE :UNiversal or any Equivalent |
| 30 | S&F for50 mm thick prestress precast cement concrete M-25 using compound wall (both Side smmothFinish), planks/panels lockingeach otherlouvres and jallies as per approved design/patterns Set in cement mortar1:4 ,(measured solid ), includingall mouldings but excluding frame as directed by Engr in charge.(Note: The quoted rate shall be inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm reinforcement , Form work)(Note:columns/ poles will be measured seperately)MAKE :UNiversal or any Equivalent |
| 31 | M & L for 75 mm thick Cement concrete type C-2, 1:3:6 using(40 mm graded stone aggregate ) as in Plinth protection. |
| 32 | Supply and fix for framed work as in doors or gates of angle or other section with gusset Plate, rails,braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges and door fittings necessary rivetting/welding cutting up complete steel conf. toFe 410-W (Gde- E- 250) quality- A all as specified and directed.Note : Distrubed surfaces of wall shall be made good to true surface. |
| 33 | Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified anddirected. |
| 34 | M&L for Glazed ceramic coloured tiles of size. 300x450x7mm thick on vertical surfaces of walls such as skirting dado etc over 10mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete.incl taking down of existing plaster/tiles/granite |
| 35 | M & L for Granite (of any type) 15-18mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing typesover 10mm thick screed bed in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete. incl taking down of existing plaster/tiles/granite |
| 36 | M & L for artificial Granite of approved colour (of any type) 15mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing typesover 10mm thick screed bed in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete. incl taking down of existing plaster/tiles/granite |
| 37 | M & L forprepolished chequered cement concrete tiles 30cm x 30cm x 20mm thick Rubber moulded with grey cementandpigment, including 15mm thick scread in CM 1:6, set jointed & pointed in neat cement slurry in floors complete all as specified anddirected. |
| 38 | M&L for prepolished precast cement concrete interlocking tiles 60 mm thick Rubber mould with strength 35 N/sqmm as in floor/pavement incllaid on 30 mm thick stone dust cushioning laid dry to the profile complete all as specified anddirected. |
| 39 | M&L for prepolishedprecast cement concrete interlocking tiles 80 mm thick Rubber moulded with strength 40 N/sqmm as in floor/pavement incllaid on 30 mm thick stone dust cushioning laid dry to the profile complete all as specified anddirected. |
| 40 | M & L for precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggreates) set in CM 1:4 as in cover slabs (for manhole etc) & simillar articles with plain faces complete (Reinforcement will be measured and paid separatly) complete all as specified and directed. |
| 41 | S & F 10mm dia TMT bars and over cut to lengthbent to shape required including craking bending, spirally for hooping for columns, hooking ends and binding with mild steel wire ( annealed) not less than 0.90mm dia of wire or secruing with clips all. |
| 42 | All as sr. item No. 41 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, spaces etc complete all as directed. |
| 43 | M&L for painting with two coats of synthetic enamel paint to steel surfaces of any description over 10cm width or girth on untreated steel surfaces over a coat of red oxide primer after preparation of surfaces complete all as specified and directed. |
| 44 | Dismantling of PVC pipes 100/75 mm bore all as specified and directed. |
| 45 | S&FPVC (SWR) pipe110 mm dia single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified anddirected. |
| 46 | S&F PVC (SWR) pipe75 mm dia single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified anddirected. |
| 47 | S&F PVC (SWR) bends 110 mm dia complete all as specified anddirected. |
| 48 | Ditto all as per sr. item No 47 above but 75 mm dia. |
| 49 | Dismantling timber scantlings 40 sq. cm and over in section, in any position from unframed work as in roof members complete all as specified and directed |
| 50 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as directed. |
| 51 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets/any type of sheet in roof coverings including ridges etc complete all as specified and directed. |
| 52 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of anycolour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws as specified and directed. |
| 53 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of anycolour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws as specified and directed. |
| 54 | Excavating in trenches, n.exc 1.5m wide and n.exc. 1.5m in depth for foundation, etc. or for shaft, wells and cesspits in soft/loose soil all as directed. |
| 55 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed. |
| 56 | Removing excavated materialbut n.exc 50 m and depositing where directed |
| 57 | M&L for RCC pre cast U shape drain with shoulder size of drain (300x200mm) outer dimensions and (200x120mm) inner dimensions with provision to cater for concrete lid or FRP lid .including making slope with proper pcc as required below drain.Make -Hindustan precast and paving ltd. or equivalent |
| 58 | Dewatering of following including disludging of sluldge at bottom in foul condition including taking out other dirty & filthy materials from manhole & septic tanks by sewage pump or manually using buckets/baskets, lifting the same upto 4.50M depth of tank/MH and removing to out side MD land including cleaning/clearing for following :- |
| 59 | Manhole of any dimension upto 1.5 Mtr deep |
| 60 | Manhole of any dimensionexc 1.5 Mtr but n exc 3 Mtr deep. |
| 61 | Cleaning of SWG/RCC Sewage line of 75 to 200mm bore dia of pipe of foul condition by rodding the drain/sewage line using flexible rod/suitable device or by any other means for removing blockage from sewar line, mud, silt and any other debries obtained from sewage line with water to remove blockage and cleaning the entire rubbish, sludge etc and burrying the material obtained from sewage line including all precautionery and safety measures etc complete all as specified and directed. |
| 62 | Removing blockage from water closet, floor or gully or Nahani Trap traps and bends by rodding thoroughly and pouring water under pressure and Cleaning, clearing the drainage to efficient and Smooth flow of sludge/waste water all as specified and directed by Engineer-in-Charge. |
| 63 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 150mm bore complete all as specified and as directed. |
| 64 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 100mm bore complete all as specified and as directed. |
| 65 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 300mm bore pipe complete all as specified and as directed. |
| 66 | M&L for 150mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge.Note : Moorum shall be measured separately |
| 67 | M&L for 100mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge. |
| 68 | M&L for 300mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge. |
| 69 | M&L for 150mm bore Reinforced concrete pipes single socketed, class NP-2, laid and jointed, complete all as specified and as directed. |
| 70 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested for 150mm & bore pipe, complete all as specified and as directed. |
| 71 | Note: Amount of sch of credit of Rs.67625/-will be deducted from total amount of BOQ. |