| 1 | Replacement of Damaged Structural Supports and Deck Plates in Gypsum Series Conveyors in PA Plant During ATA 2026 |
| 2 | Fabrication,Repair and Replacement of Damaged Structurals Supports of Gypsum Series Conveyors InPA Plant:Collection of required materials from FACT -CD stores / plant area and transport to the work site. Make necessary site arrangements for the work. The damaged structurals of gypsum conveyors mainly head/tail/snub/bend pulley supports and associated structures/ foundations,discharge chute area structures and supports, main bed membersof conveyors and supports, vertical supports, main supports from ground and its members and any other structurals in connection with the conveyors shall be cut and removed as per site instructions. Required temporary supports shall be provided. New structures and foundations shall be fabricated and erected to meet site requirement. Erected structurals shall be full welded.Any patch work on thre chute shall also be done with suitable material by the contractor as per site instruction. Cleats for return idlers, positioning of idler frames shall be done as per original design. The replaced structurals shall be painted with 2 coats of zinc chromate yellow primer and 2 coats of enamel paint after required surface cleaning. The scope of supply of paints, primer and assosiated consumables shall be in contractor\"s scope. Damaged structurals shall be transported to scrap yard/area earmarked as per the instruction from site in charge. |
| 3 | Fabrication and Replacement of Damaged Deck Plates of G3 and G4 ConveyorsCollect required tools,tackels and materials for the work. Mark and cut and fabricate deck plates for G3/G4 conveyors out of 3/3.15mm SS/MS plate,size to suit exixting site condition. Release the belt tension at site after getting process clearence. Dismantle the troughing idler/self aligning frames and idlers. Cut and remove the damaged deck plates. Mount the new deck plate in position and weld it to main beam. Erect the troughing idler frames as per original design and fix it in position by welding/bolting.Mount back the idlers. Return idlers shall also be mounted in position. After the complete work release the conveyor belt to original tension. Scrap/damaged plates/beam shall be transported to scrapyard. |
| 4 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 5 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3.5 cores x 50 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 6 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3 cores x 50 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 7 | Supply/unloadingand Handingover of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured PVC outer sheathed cable of size 3 cores x 35 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 8 | Supply/unloadingand Handingover of650/1100V, Aluminium unarmoured, earthing cable of size 1 core x 70sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 9 | Supply/unloadingand Handingover of650/1100V, Aluminium unarmoured, earthing cable of size 1 core x 35sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 10 | Supply/unloadingand Handingover of650/1100V, Copper conductor PVC insulated, armoured PVC outer sheathed cable of size 5 cores x 2.5 sq.mm. The cable shall be supplied at Q10 installation of FACT at Willingdon Island and must be unloaded as per the instruction of engineer-in-charge. Vechicles/loading and unloading shall be in contractors scope |
| 11 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 400 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 12 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5 cores x 185 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 13 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3.5cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 14 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 50 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 15 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 3 cores x 35 sq.mm., aluminium conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 16 | Supply of single compression nickel plated brass cable glands suitable for 650/1100V cable of size 5 cores x 2.5 sq.mm., copper conductor, PVC/XLPE insulated, armoured, PVC outer sheathed. The bidder shall varify the entry thread, type of enclosure etc, to find out the actual type of gland required. |
| 17 | Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 300 sq.mm. |
| 18 | Supply of heat srinkable cable jointing kit for armoured cable of size 3 cores x 185 sq.mm. |
| 19 | Supply of heat srinkable cable jointing kit for armoured cable of size 3.5 cores x 120 sq.mm. |
| 20 | Supply of cable tags, aluminium or SS for cables (cable No. pre-fix will be given at the time of erection) |
| 21 | Supply and Installtion of UG LT Cable Route Marker as per engineer in charge instructions for cable identification |
| 22 | Laying of 650/1100V, Aluminium conductor PVC/XLPE insulated, armoured, PVC outer sheathed cable of size 3.5 cores x 400 sq.mm. through the existing cable tray at Q10 substation 25 mts / excavated trench 85Mts and cable trayat phosphorc acid dic wall (35 Mts) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 23 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3/3.5 x 50 sq.mm. through the existing and newly fabricatedcable trayat various locations in Q10 berth installations of FACT, as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 24 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3 x 35 sq.mm. through the newly fabricatedcable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 25 | Laying of 1 core x 70sq.mm. (2 Run x 110 Meter) unarmoured, earthing cable through the existing cable tray at Q10 substation 25 mts / excavated trench 85Mts and cable trayat phosphorc acid dic wall (35 Meters) as per the instruction of engineer-in-charge. The scope of work shall also include laying, dressing, fixing on cable trays/racks/risers/walls/columns clamping, tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 26 | Laying of1 core x 35sq.mm. unarmoured, earthing cable through the newly fabricatedcable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 27 | Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 5 cores x 2.5 sqmm armoured coper cable (4 run x 35 Meter) through the newly fabricatedcable trayat phosphorc acid dic wall, as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 28 | Rerouting and Laying of650/1100V, Aluminium conductor PVC/XLPE insulated, armoured,PVC outer sheathed cable of size 3.5 x 185 sq.mm. through the excisting cable trayat phosphorc acid dic wall , as per the instruction of engineer-in-charge. The scope of workshallalsoinclude laying, dressing, fixing on cable trays /racks /risers /walls /columnsclamping,tagging, tying, minor civil work etc. The rates quoted shall include supply of all accessories required such as,cable clamps,bolts, nuts, washers, cable tags, nylon ropes, etc. |
| 29 | Glanding and Termination of cable of size 3.5 corex 400 sq.mm. at PAT MCC Incomer and substation out going with suitable lugs and crimping. |
| 30 | Glanding and Termination of cable of size 3.5 corex 185 sq.mm. at PAT MCC Outgoing with suitable lugs and crimping. |
| 31 | Glanding and Termination of cables of size 3.5 core x 50 sq.mm.at various locationsin Q10 berthinstallations of FACT with suitable lugs and crimping. |
| 32 | Glanding and Termination of cables of size 3 core x 50 sq.mm. at PAT to motor terminal (30 KW Motor, 2 Nos.) with suitable lugs and crimping. |
| 33 | Glanding and Termination of cables of size 3 core x 35 sq.mm. at PAT to motor terminal (15 KW Motor, 2 Nos.) with suitable lugs and crimping. |
| 34 | Termination of earthing cable of size 1 core x 70 sq.mm. at PAT MCC and substation with suitable lugs and crimping. |
| 35 | Termination of earthing cable of size 1 core x 35 sq.mm. at PAT MCC to motor terminals at acid P2O5 pump house with suitable lugs and crimping. |
| 36 | Glanding and Termination of cables of size 5 core x 2.5 sq.mm. at PAT MCC module to motor push button station with suitable lugs and crimping. |
| 37 | Jointing of armoured cable of size 3.5 cores x 300 sq.mm. using heat srinkable cable jointing kit |
| 38 | Jointing of armoured cable of size 3 cores x 185 sq.mm. using heat srinkable cable jointing kit |
| 39 | Jointing of armoured cable of size 3.5 cores x 120 sq.mm. using heat srinkable cable jointing kit |
| 40 | Excavation and back filling of cable trench for laying power/ earthing cables/ cable trench of not less than 300 mm width and 600 mm depth(0.6 meter depth from ground level) |
| 41 | Shifting of existing PAT MCC to temporary shed. The scope of work includes dismandling MCC and all incoming/outgoing cables and shifting to nearest temporary shed./reassembling/fixing the MCC and providing 1 number of incoming cable of size 3.5 cores x 400 sq.mm. and 5 numbers of out going power cables (2 no.s of 3 cores x 50 sq.mm.,2 no.s of 3 cores x 35 sq.mm.,1 no.s of 3.5 cores x 185 sq.mm.) and 4 numbers of control cables (5 cores x 2.5 sq.mm.) in newly fabricated cable tray/trench with suitable single compression gland. |