| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 2 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rockall as specified & directed by Engineer-in-Charge. |
| 3 | Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified and directed by the Engineer-in-Charge. |
| 4 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engineer-in-Charge. |
| 5 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. |
| 6 | Removing excavated soil to a distance not exceeding 50 m and depositingwhere directed at a level not exceeding 1.5 mabove the starting point complete all as specified & directed by Engineer-in-Charge. |
| 7 | Taking down defective/unservicable solar street light/ Flood light/solar PV panel ,any type of battery ,GI brackets, fitting of any size /type/capacity any Watt from height of pole for repair work and fixing back after repair work including checking, inspecting, testing and commissioning complete all as specified.Note :- (a) Spares like drivers,battery ,PIR motion sensor , LED Driver,surge protector,light, etc. shall be measured and paid asseparetely under relavant items of schedule\"A\" (b) Necessary tools like mobile ladder & other T&P required etc shallbe arranged by the contractor without any extra cost.(c) The rate quoted deemed to be inclusive for minor repair parts like nuts, bolts, cirle clips , clamps etc required if any at site. |
| 8 | Supply and fix in repair of electronic driver for LEDflood light fitting, LED out put power 100 watt, input voltage range : 170 - 300 volt AC , out put voltage DC as per make/ model range: 24 volt to 110 volt, make as per site requirement complete all as specified. |
| 9 | All as per item No 8 above but capacity 150 watt |
| 10 | All as per item No 8 above but capacity 200 watt |
| 11 | All as per item No 8 above but capacity 250 watt |
| 12 | Supply and fix in repair Surge Protector10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified. |
| 13 | Supply & Fixing in repair Led Flood Light Fitting 150 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And TotalLumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make –Crompton/Havells/BajajCrompton Cat no TFS-507-150-57-60 D-SL-GL-NSG Bajaj Cat no:- JENXT P180L WH PO TG SD Orient Cat no:-Orient cat no:LFSM-150-C-V3 or equivalent in Appx \"C\" list of makes. |
| 14 | Supply & Fixing in repair Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And TotalLumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make –Crompton/Havells/Orient Crompton Cat no TFS-507-200--57-60 D-SL-GL-NSG havells Cat no:- JETAIRIMAXFL200WLED757PWBLTG Orient Cat no:- :LFSM-200-C-V3 or equivalent in Appx \"C\" list of makes. |
| 15 | Supply & Fixing in repair Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And TotalLumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic As all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/Bajaj – Crompton Cat noCFS-506-250-57-30D-HL2-GL-NSG,Havells Cat No :-JETAIRIMAXFL250WLED757PWBLTG , Orient cat no:LFSM-250-C-V3 or equivalent in Appx \"C\" list of makes. |
| 16 | Supply & Fixing in repairLed Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy >= 120lm/W And TotalLumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F > 0.95, , Cct – 5700k,Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X 1.5 Sqmm Frlsh Wire, All As Per Directed By Eic all as specified and directed by Engr-in-Charge Per Make Crompton/Havells/orient–Cat no CFS-512-400-57-30D-SL-GL-NSG ,havells Cat No:- JETAVALOURLEFL400W3MLED757PINTNBLTG Orient cat no:LFSMU-400-C or equivalent in Appx \"C\" list of makes. |
| 17 | Supply & Installationin repair of Mono crystalline Solar PV Panel of 12V 135Wp (Suitable for 30 Watt solar light) with wires and connectors to fit in existing system,complete all as specified & directed by Engr-in-Charge. |
| 18 | Supply & Installationin repair of Mono crystalline Solar PV Panel of 12V 80Wp (Suitable for 9 to 12 Watt solar light) with wires and connectors to fit in existing system,complete all as specified & directed by Engr-in-Charge. |
| 19 | S & Fin repair/replacement of PVC insulated, sheathed weather proof, copper conductor of size 2.5 sqmm, 2 core complete all as specified. |
| 20 | Supply & Installation in repairof 12 watt LED street light Luminary for solar light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI >70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant. complete all as specified & directed by Engr-in-Charge. |
| 21 | Supply & Installation in repair of 30 wattLED street light Luminary for solar light with inbuilt charge controller, High brightness W-LED(120-180lm/watt) lamp with proper optics lens for better light distribution , CRI >70, Color Temperature 6500K, Microcontroller based charge controller cum driver, automatic dimming function, Dusk to Down Operation, Protections: Short Circuit, overload, Reverse polarity and battery protections. With Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS, IP66 and IK08 Compliant. complete all as specified & directed by Engr-in-Charge. |
| 22 | Supply & Installation in repair of Maintenance free lead Acid VRLA type Battery 12V80 Ah (Suitable forsolar street light,warrenty minimum 24 month of battery) with other necessary wires and connectors suitable for existing system.complete all as specified & directed by Engr-in-Charge. make Exide,amron,luminious |
| 23 | Supply & Installation in repair of Maintenance free lead Acid VRLA( maintancefree battery type Battery 12V40 Ah withcharge controller(Suitable forsolar street light warrenty up to 36 month of battery) with other necessary wires and connectors suitable for existing system.complete all as specified & directed by Engr-in-Charge. |
| 24 | Supply & fix in repairof Solar Charge Controller for inbuiltsolar streetlightall in one MPPT 10 Amp with protection circuit Solar streetLight System: 12V Nom inal Capacity: 80Wp Max Regulation: Low Loss, Shunt Type OVD: Output Voltage Dropcomplete all as specified & directed by Engr-in-Charge. |
| 25 | Supplyand fix in repair of of PIR Motion Sensor 170uA forSolar street Lightall in one Standard Detection 5m Lens Color : Whitecomplete all as specified and directed by Engr -in- Charge |
| 26 | Supply & fix in repair & Installation of Lithium Battery 12.8V/ 42 Ah (Suitable for 16 to 40 Watt solar light) with BMS Circuit and other necessary wires and connectors suitable for 16 to 40 watt Integrated all in one Solar Lightscomplete all as specified and directed by Engr -in- Charge. |
| 27 | Supply & fix , Installation,in repair of Lithium Battery 12.8V/ 36Ah (Suitable for12 to 16Watt solar light) with BMS Circuit and other necessary wires and connectorsall as specified & directed by Engr-in-Charge. |
| 28 | Supply & fixing in reapirof Rocker Switch 6 to 10Amp for solar lights complete all as specified and directed by Engr -in- Charge. |
| 29 | S&F in repair solar street light of 20 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integratedwithpolyurethane coating camouflag colour servicable battery compartment, solar PV panel of 35-40 WP mono crystalline,, Lithium battery 12.8 Volt, 18-24 Ah LiFeP04 , Min Lux level >3000 Lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30%start dimming brightness glow to 100% for 30 second upon motion detectionHigh brightness luminous efficiencyW-LED (135-180 Im/Watt),life span of of LED >50,000 Hrs , protectionlamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automaticfix motion dimming functionwith PIR motion sensor,Dusk to dawn operation, ,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%,with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :- Crompton cat no-CSOP-814-20-57-HL5-FD-LM-SR or equivalent in Appx \"C\" list of makes. Note : Short Circuit, overload, reverse polarity and battery protections to be provided.OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS,IP65/ 66 and IKO8 complaint |
| 30 | S&F in repairsolar street light of 30 watt all in one FRP/Aluminium extruded Lithium based energy efficient Integratedwith polyurethane coating camouflag colour servicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level >4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30%start dimming brightness glow to 100% for 30 second upon motion detectionHigh brightness luminous efficiencyW-LED (150-180 Im/Watt),life span of of LED >50,000 Hrs , protectionlamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :-Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent in Appx \"C\" list of makes.Note : Short Circuit, overload, reverse polarity and battery protections to be provided.OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS,IP 66 and IKO8 complaint. |
| 31 | S&F in repairsolar street light of 40 watt all in oneFRP/ Aluminium extruded Lithium based energy efficient Integratedwith polyurethane coating camouflag colourservicable battery compartment, solar PV panel of 48-60 WP mono crystalline,, Lithium battery 12.8 Volt, 24-30 Ah LiFeP04,Min lux level >4500 lumens ,MPPT Charger with inbuit BMS Technology ,PIR motion sensor system at 30%start dimming brightness glow to 100% for 30 second upon motion detectionHigh brightness luminous efficiencyW-LED (150-180 Im/Watt),life span of of LED >50,000 Hrs , protectionlamp with aluminium reflector for better lighting distribution, CRI > 70, colour temperature 5700 ANSI, Microcontroller based charge controller cum driver in built DC type, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR motion sensor,Dusk to dawn operation,and,working temp : (-10 C ) to (+) 55 C ,humidity range 0-95%, weight15-20 KG with adjustable MS Clamp suitable for existing pole/wall mounting ,low votage indication ,charging indication ,with bty over charge protcetion ,Bty deep discharge protection ,No load/Open load protection etc complete all as specified and directed by Engr-in-Charge. Make :-Crompton cat no-CSOP-815-30-57-HL5-PIR-LM-SR or equivalent in Appx \"C\" list of makes. Note : Short Circuit, overload, reverse polarity and battery protections to be provided.OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS,IP 66 and IKO8 complaint. |
| 32 | Supply and fixing in replacement of copper wire 2.5 Sqmm 6 core suitable for high mastlight all as specfiedand directed by Engineer -in -charge |
| 33 | Taking down and dismantling existing high mast pole of height 12 to 20 mtr from bottom plate ,nuts bolts, gear box and head frame for dismantling the unserviceable parts including repair control panel wiring, old unsv lights, complete with the help of suitableT & P required for holding ,lifgting the pole,replacement of unservicable part,oiling and greasing,of pulleys,gear box,rope and all moving parts including assembling,installation of high mast pole complete as directed by Engineer-in charge. (Note 1. cost of crane for dismantling high mast pole is deemed to be included in quoted rate. 2. Cost of oling and greasing of moving parts is deemed to be quoted rate. |
| 34 | Taking down by disconnected the existing electrical connection of winch motor for rewinding /repairs including rewinding the mortor of capacity up to 2 HP with best class supper enameled copper wire of existing guage and size including varnishes and insulating 230 V AC 50 HZ electric supply system . refixing and reconnected it to theoriginal location for satisfactory functioning of wintch on 230 v electric supply system all as specfied , |
| 35 | Supply & fix MNX Power contactor suitable for power supply 40 Amps 4 pole4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make:Legrand or equivalent make of Havells/L&T. |
| 36 | Supply & fix MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor complete all as specified & directed by Engr-in-Charge. Make:Legrand or equivalent make of Havells/L&T. |
| 37 | S&F in repair Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors complete allas specified and directed by Engineer-in-charge. |
| 38 | S&FNature switch( using infrared sensor technology ) based automatic street light control panel. The panel should be enough to take three phase load of 3-5 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is <=60 and for Switching OFF >=10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable3 phase load of 3-5 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 40 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor Manual or Autooperation . complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply & fixin repair MCB, SPN, 32 Amp, 240 Volts, \"C\" Curve 10KAincluding dismantling old oneComplete all as specifed and directed by Eng-in-Charge. |
| 40 | Supply and fixing 415V 10KA \"B\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. TPN 40 to 100 Amp including taking down and dismentaling old one Complete all as specifed and directed by Engr-in-Charge. |
| 41 | Supply & fix in repairMCCB 415V, 3 phase 50 HZ 4 pole 63 Amps breaking capacity 16 KA (Ics = 100% Icu) with including dismantling old one connection link on LT panel /fedder piller Complete all as specifed and directed by Eng-in-Charge |
| 42 | Supply ,laying, test and commissioning in repair of LT UG ,XLPE insulated, heavy duty, 1100V grade ofelectric cable size 16 Sqmm 4 core with aluminium conductor ,served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands ,lugs,bushing etc as requiredcomplete all as specified and directed by Engineer-in -Charge of following size:-Note: Earthwork excavation sand cushioning ,Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items. |
| 43 | All as above item no 42 but size 25 Sqmm4 core |
| 44 | All as above item no 42 but size 35 Sqmm 3.5 core |
| 45 | Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 40 mm outer dIa 32 mm bore as per is 16205 part 24 cable protectionincluding all fitting as required complete all as specified and directed by engineer- in-charge. |
| 46 | Supply and laying DOUBLE WALL CORRUGATED (DWC) pipe 50 mm outer dIa 38 mm bore as per is 16205 part 24 cable protectionincluding all fitting as required complete all as specified and directed by engineer- in-charge. |
| 47 | S&F In rtepair of GI Pipe of 80 mm in single length (20 ft /06 mtr )for solar street light complete all as specified & directed by Engr-in-Charge. |
| 48 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified & directed by Engr-in-Charge. |
| 49 | M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of stay assembly including necessary form work all as specified and directed by Engr-in-Charge. |
| 50 | M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete allas specified and directed by Engr-in-Charge. |
| 51 | Supply & fixin repair 40 mm bore GI tubing medium grade in trenches or on pole for cable protection complete all as specified and as directed. |
| 52 | Supply & fixin repair 50 mm bore GI tubing mediumgrade in trenches or on pole for cable protection complete all as specified and as directed. |
| 53 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deepacross the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified. |
| 54 | Supplyand, fixing fabricate structural mild steel RS joist , channelangle iron, flat iron and brackets etc for fabrication of cross arms, bracing supports clamps including D clamps, eye hook and back plate etc fabricated from structural steel section includingnuts , bolts, washers, welding (cold and hot ) drilling holes for bolts, bend to any shape or size as indicated and directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfacescomplete allas specified and directed by Engineer-in-charge. |
| 55 | Note No.1 : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaintthroughoutjaisalmer cantt area.(b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint within minimum time, if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge.(d) Complaint should be attend in Night also Note No.2 : Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department. |