| 1 | Excavation in trenches in Soft/loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of GIpipe line and making bottom surfaces of excavationlevelled and to a gradient.Note:(i) During excavation to pipe line, if any damage occurs to other pipe line/electric line/ communication line etc at site, the contractor will be solely responsible to repair without any extra cost. If the contractor does not repairs the same,then damage charges for getting the same repaired through other resources shall be recovered fromrunning payment/final bill of contractor as per direction of Accepting officer.(ii) Tenderer is requested for site visit before quoting the tender for assessment of Old Pipeline route and credit sch. |
| 2 | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm after the pipes have been laid all as specified and directed. |
| 3 | Removing excavated material / soil to a distance n. exc 50 m above starting point complete all as specified and directed. |
| 4 | Taking up cast iron watermainsof 100mm bore of pipe (including all fittings), with spigot and socket endsand all accessories all as specified and directed. |
| 5 | Supply & Fix in Ductile Iron Pipe 100 mm K-7 Class Spigot & Socket type with all necessary fitting and fixture any type complete all as directed. |
| 6 | Taking up or down 25mm dia size of rusted GI water tubing and connections of pipe and fittings from sitecomplete all as directed. |
| 7 | All as per ser Item No - 06 above but pipe size 20mm dia. |
| 8 | Supply and fixing GI tubing \"Medium grade\" 25 mm bore, with all fittings( Tee, Elbow, Nipple, Reducer, Union) clamps screws MS clamps, hooks complete on laying of pipe in ground/fixed on wall/floor/ceiling all as specified and as directed. |
| 9 | All as per ser item No-08 above but for GI pipe size 20mm dia. |
| 10 | M& L in replacement of Gun metal gate valves with iron wheel head , screwed both ends for 25mm medium grade GI pipes all as specified and directed. |
| 11 | All as per ser item No - 10 above but for GI pipe size 20mm dia. |
| 12 | Labour for cutting cast iron pipes of 100 mm bore in position and reducing to required lengthfor insertion of new tees,branches, Mechanical Joints etc, complete all as directed. |
| 13 | M & L for repairing to damaged portion ofvalve pit chamber on existing chamber foundation with 230 mm thick brick wall in CM (1:6) 75 mm thick coping with PCC 1:2:4 type B1, 15 mm thick plaster work in CM 1:4 over all internal and external wall with white wash of both surface and Chequered plate cover of 7mm thickness for Valve Pit Chamber of size upto 900x900x750 mm with hinges, equal angle iron frame(40x40x4mm) and necessary locking arrangement painting of synthetic Enamel paint over coat of red oxide primer on Plate including dismantling existing damaged portion of chamber and removal of all debris all as specified and directed . |
| 14 | S&F in replacementSluice Valve complete as per IS : 14846 / 2000 with Stainless Steel Spindleduly ISI Marked Flange as per IS: 1538 DI class PN 1.6 flanged type of size100 mm, including all minor fixing arrangement complete all as directed. |
| 15 | M & L for repairing to damaged portion ofvalve pit chamber on existing chamber foundation with 230 mm thick brick wall in CM (1:6) 75 mm thick coping with PCC 1:2:4 type B1, 15 mm thick plaster work in CM 1:4 over all internal and external wall with white wash of both surface and Chequered plate cover of 7mm thickness for Valve Pit Chamber of size upto 450x450x600 mm with hinges, equal angle iron frame(40x40x4mm) and necessary locking arrangement painting of synthetic Enamel paint over coat of red oxide primer on Plate including dismantling existing damaged portion of chamber and removal of all debris all as specified and directed .Note : All necessary raw materials deemed to be included in quoted rates. |
| 16 | M&L for cutting existing bituminous road upto 0.5 Mtr depth and width not exc 30cmfor laying of pipe line of any size (up to 100mm dia), refilling and making good after laying of pipe with removed soil/debris/dust and finally sealed with patchmatof thickness not less than 15cm to match with the top surface of Road.Note : Rate for patchmate shall be deemed to be included in above quoted rates. |
| 17 | M&L formechanical joint of size 100mm dia for connecting to the 100mm dia CI Pipe to 100 MM dia DI Pipe all as specified and directed. |
| 18 | M & L for of Ductile Iron K-7 classSpecial fitting ofIS 9523 any typespigot and socket ends or flanged pipe with jointing ring/material as required at site (such as bend, taper, Tee, flange, socket, coller, Reducer, angled branch etc) Socket end/ flanged as ordered of 100mm dia complete all as directed. Note:-(i) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less.(ii) All fittings shall bear relevant IS stamping marking.(iii) Excavation and earth work shall be measured and paid separately.(iv)Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before. |
| 19 | Dismantling the drain,footpath any type and any width during replacement of damaged GI pipe line of size 25 mm, and making good the surface as per existing by using bricks, stone, paved bricks,Sahibabad tilesall as specified and directed.Note : (i) The rate of bricks, stone, paved bricks,Sahibabad tiles, cement , sand, stone aggregates are deemed to be included in the quoted rates. (ii) If the contractor not repairingthe patches then the total repaired cost including penalty @ 25% of repairing costis calculated andthe amount should get recovered from the contractor\"s Bill. |
| 20 | Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed.Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI wire above 7.5m will be measured and paid seperately. |