| 1 | M&L for locating the fault in underground electrical power cable of any length & any type of 1100 volt grade LT cables, by arranging portable fault locating Machine suitable for underground LT power cable faulty detection ,including pre location and pin point capability using TDR or similer advance technology the fault, cutting the cable at fault to fixing the joint including testing of the cable after locating fault and jointing cable including excavation and earth work in any type of soil completeall as specified and as directed.Note:- (i) Cable Joint shall be measured and paid separately under respective item of this Schedule. (ii) If fault is not rectified within 24 hours after receiving complaint, the contractor shall be charged damage for Rs 500/- per day per complaint and shall be deducted from payment due to contractor. |
| 2 | S&F straight through jointing kit for 1.1 kv XLPE/PVC insulated cable size 10sqmm- 25sqmm including all accessories such as lugs/ferrule,heat shrink sleeve,insulated tape, sealing compounds, mechanical and electrical protection as per manufacturer recommendation includes prepration of cable end,crimping of connectors,cleaning, application of anti corrosion compond complete in all aspect all as specified and as directed. |
| 3 | Description all as per item no 2.00 above here in before but cable size 35sqmm-50sqmm. |
| 4 | Description all as per item no 2.00 above here in before but cable size 70sqmm-95sqmm. |
| 5 | Description all as per item no 2.00 above here in before but cable size 120sqmm-240sqmm. |
| 6 | Description all as per item no 2.00 above here in before but cable size 300sqmm-630sqmm. |
| 7 | Supply,Installtion and termination of high conductivity electrotinned copper compression lugs suitable for cable size 10 sqmm-25sqmm stranderd cable M-6/M-8/M-10/M-12 stud hole size, with inspection hole to comply IS 8309 standerd complete in all aspect all as specified and directed. |
| 8 | Description all as per item no 7.00 above here in before but cable size 35sqmm-50sqmm. |
| 9 | Description all as per item no 7.00 above here in before but cable size 70sqmm-95sqmm. |
| 10 | Description all as per item no 7.00 above here in before but cable size 120sqmm-150sqmm. |
| 11 | Description all as per item no 7.00 above here in before but cable size 185sqmm. |
| 12 | Description all as per item no 7.00 above here in before but cable size 200sqmm-240sqmm. |
| 13 | Description all as per item no 7.00 above here in before but cable size 300sqmm-400sqmm. |
| 14 | Description all as per item no 7.00 above here in before but cable size 500sqmm-630sqmm. |
| 15 | Repair/Rectification for street light / Security light /perimeter light/flood light of any type and any make and any capacity against complaint received in person to make the street/security light in serviceable and functional condition as intimated by JE-in-chargeby rectification /trace out the fault which includes disconnecting connection wires, removing/taking down of street /security light fitting from wall bldg/plint /LT/HT PCC Pole/ Steel Tubelar/ swan neck pole/ octagonal poles upto 11 meter height from ground level or any other location,Diagnosing the fault, replacing the defective spare part/connection wire or any other part in presence of JE(E/M) or dept rep etc cleaning of light fitting/glasses/acrylic cover,reassembling testing for functioning ,refixing to the pole making necessary connection or tightining the loose connection including any type of minor repair as required to make light functional.NOTE:-The schedule of work must include as following(i) Light fitting ,flexible wire and LED driver, street light timer, MCBs, Contractor,Junction Boxor any other item etc if required to be required repair/replace shall be measured and paid seperatly under relevent item of this BOQ.(ii)Complaint shall be rectified within 4 hours of receipt of complaint.(iii)The contractor will maintain complain register regarding details of daily complaint recevied, pending, rectified item replaced on daily basis duly signed by Contractor and JE(E/M).(iv)Transportation and T&P incl ladder, spanner /Hydra or any other equipment for repair/replacement of street light/security light/highmast light shall be provided by contractor and cost of same deemed to be includein quoted rate. |
| 16 | M&L for dismantlingof high mast light for any hight and any capacity including repair to raising and lowering system of high mast light and reppair to doubledrum winch,proper checking of lubrication system checking and tighting of trailing cable reapir to remote for up and down of lantern carriage,fixing of flood light luminaries , replacement/repair of flood light complete with suitable size of braket and making serviceable including base protection of high mast light all as specified and as directed.NOTE:-The schedule of work must include as following.(i) Light fitting ,flexible wire and LED driver , street light timer, MCBs, Contractor,Junction Boxor any other item etc if required to be required repair/replace shall be measured and paid seperatly under relevent item of this BOQ.(ii)Complaint shall be rectified within 4 hours of receipt of complaint.(iii)Transportation and T&P incl ladder, spanner /Hydro crane or any other equipment for repair/replacement of highmast light shall be provided by contractor and cost of same deemed to be include in quoted rate. |
| 17 | Excavation in trenches not exc. 1.5 mtr width and not exc 1.5 m deep in soft loose soil for laying/taking up/taking down of cablesand getting out and excvation for Poles upto 1.5 m levelling of bottom surface to required level all as specified and directed by Engr-in-charge. |
| 18 | Excavation in trenches not exc. 1.5 mtr width but additional to 1.5 m deep in soft loose soil for laying/taking up/taking down of cablesand getting out and excvation for Poles upto 1.5 m levelling of bottom surface to required level all as specified and directed by Engr-in-charge. |
| 19 | Material and labour for river washed and screened , dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed. |
| 20 | Taking out old bricks and S&F sub class \"B\" bricks having minimum compressive strength 75 Kg/sqcm laid in trenches for cable protection etc complete all as directed by Engr-in-charge. |
| 21 | Returning Filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 22 | Removing Excavated material (i.e soil) from site to a distance not exc 50 mtrs awar and depositing where directed at a level not exc. 1.5 meter above the starting point all as specified and directed by Engr-in-charge |
| 23 | Supply, laying and testing of 3.5 /4 core10 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/RR Kabel / Finolex |
| 24 | Supply, laying and testing of 3.5 core16 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/RR Kabel / Finolex |
| 25 | Supply, laying and testing of 3.5 core25 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/RR Kabel / Finolex |
| 26 | Supply, laying and testing of 3.5 core35 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/RR Kabel / Finolex |
| 27 | Supply, laying and testing of 2 core10 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/RR Kabel / Finolex |
| 28 | Supply, laying and testing of 2 core06 sqmm size XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade complete all as specified and as directed. Make:- Polycab/ RR Kabel / Finolex |
| 29 | Supply and fix in replacement 1100 volt grade 2.5 sq mm 3 core PVC FRLSH Cable complete in all aspect all as specified and directed. Make : Polycab/ Finolex/ RR Kabel |
| 30 | Supply and fix in replacement 1100 volt grade 6 sq mm 3 core PVC FRLSH Cable complete in all aspect all as specified and directed. Make : Polycab/ Finolex/ RR Kabel |
| 31 | Supply and fix in replacementof factory made CPRI approved , outdoor type double door construction street light feeder piller panel constructed with minimum 3.15 mm thick stainless steel sheet ,duly powder coated ,provide with a canopy/sloped roof ,neoprene/EPDM gasketting , suitable lifting hooks and robust locking arrangemant with key, suitable for opeartion on 415 volt , 3 Phase 4 wire 50 Hz AC supply , totally enclosed dust proof ,fully wired up and ready to connect load & control line in comprising the followings including all necesssary internal wiring, control wiring, ferruling, terminal block, cable gland, cable lugs, danger plate, foundation bolt and dedicated earthing terminal complete in all aspect with necessary GI frame foundation and required civil work for PCC of footing complete all as specified and as directed.1.Incommer -MCCB 160 Amp, 25 KA Breaking capacity,Type C Curve -01 No2.Set of Copper Busbar 4 No (R,Y,B,N) rated for the current rating of 160 Amp - 01 set3.Power Contractor 4 pole, 160 Amp AC3 duty for switching the street light - 01 No4.Digital/Analog programmable cyclic timer switch (with battery back up suitable for the panel rating)5.Auto/Manual selector switch (heavy duty,rotary type) for manual over ride.6.Outgoing- 2 Nos of 100 Amp MCCB (16 Amp Breaking Capacity Type C)7.One no of 4 pole earth leakage circuit breaker (ELCB) for overall earth fault protection8.Meteing and indication8.1. 1 No Digital Multi Function meter (Volatge , current ,freq , PF, Energy etc)8.2. 3 Nos Current Transformer (CTs) for metering8.3. 3 Nos LED indication lamp (R,Y,B) for Phase indication.Note:- Rate quoted in BOQ shall include GI frame foundation for Street light panel with necessary civil work complete in all aspect all as specified and directed. Make:- Hensel/ Havells/ Universal switch gear |
| 32 | Supply, dismantling, and replacement of existing unserviceable street light luminaires with new high-efficiency LED fixtures featuring a pressure die-cast aluminum housing with IP66 ingress protection and IK08 impact resistance. The scope includes the safe removal of old fixtures, cleaning of existing outreach arms, and installation of the new unit using AISI 304 stainless steel fasteners, ensuring a minimum system efficacy of 140 Lm/W and a correlated color temperature (CCT) of 5700K. Technical requirements encompass an integrated 10kV surge protection device (SPD), a high-power factor driver ($PF > 0.95$) with total harmonic distortion (THD) of less than 10%, and internal rewiring from the junction box using 1.5 sq.mm 3-core FRLS copper flexible cable complete in all as specified and as directed. Make Philips /Havells/Goldmedal/CG. |
| 33 | Description all as per above item no 32 here in before but 60W LED street light. |
| 34 | Description all as per above item no 32 here in before but 90W LED street light. |
| 35 | Description all as per above item no 32 here in before but 120W LED street light. |
| 36 | Description all as per above item no 32 here in before but 150W LED street light. |
| 37 | Description all as per above item no 32 here in before but 170W LED street light. |
| 38 | Description all as per above item no 32 here in before but 230W LED street light. |
| 39 | Supply, installation, testing, and commissioning in replacement of a high-performance LED floodlight luminaire designed with a heavy-duty pressure die-cast aluminum housing and specialized asymmetric or symmetric secondary optics for wide-area illumination. The unit shall feature an IP66 weather-proof rating, IK08 impact resistance, and high-quality LEDs delivering a system efficacy of at least 130 Lm/W with a color temperature of 5000K-6500K. Technical specifications include an integrated 10kV surge protection device, a programmable constant-current driver with a power factor >0.95, and THD <10%, ensuring stable operation under voltage fluctuations. The scope covers mounting the fixture via a heavy-duty G.I. \"U\" stirrup bracket on existing high masts or structures, including all necessary SS-304 hardware, internal 3-core 2.5 sq.mm FRLS copper wiring complete in all as aspect all as specified as directed. Make : Philips /Gold Medal /Havells / CG. |
| 40 | Description all as per above item no 39 here in before but 100W LED flood light. |
| 41 | Description all as per above item no 39 here in before but 150W LED flood light. |
| 42 | Description all as per above item no 39 here in before but 100W LED flood light. |
| 43 | Supply, fixing and connecting in replacementof decorative post top LED luminaries made of die-cast aluminium housing with clear/opal polycorbonate diffuser,suitable for outdoor installtion on pole top/gate light,complete with all accessories complte equipped with 40 watt high-efficiency LED module having colour tempreture 6500 K(cool white) with system efficiency of 100 lm/watt and total lumen output nit less than 4000 lumne.The fitting shall have an IP65 or higher protection rating and IK07 impact resistance,operating on 230+ 10%, 50 Hz AC supply,including integral electronic driver with inbuilt surge protection complete in all aspect all as specified and as directed. |
| 44 | Description all as per above item no 43 here in before but for cool tempreture of 3000 K(warm white). |
| 45 | Supply, fixing and connecting in replacement LED Based bollard 15 watt capacity with aluminium pipe housing, PDC Base and top cover with glare free Big Mushrooom shaped PMMA diffuser, IP 65, Hight 800 mm complete all as specified and as directed. |
| 46 | Supply andfix PP-R pipes 3 Layers with connected accessories of 20 mm dia on Street light Pole complete in all aspect all as specified as directed. |
| 47 | Supply and fix street light pole Pre fabricated GIClamp of double head braket for securely fastening electrical cable conduit (PPR) to lighting pole.The clamp shall be fabricated from galvanized steel / stainless steel (as specified) and designed to accommodate cable conduit of 20 mm suitable for mounting on circular or orthogonal pole of existing diameter in vertical direction including all required accessories U-Bolt,washer,nuts and vibration resistance grommets complete in all aspect all as specified and as directed. |
| 48 | Supply,Installtion,testing and commissioning of High galvanised 11 Meter mast light suitable for 6 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6mm dia 97/19 gauge and double drum winch with luminarie mounting arm,pully assembly,aviation obstruction light, lightning arrester spike including RCC foundation asper height complete including 6 Nos of 210 watt LED floor light complete in all as specified and as directed:-(i)Supply and fix of rising lowering system comprising double drum winch,6mm diameter SS wire rope,trailing cable, connector.(ii) Supply of foundation bolts manufactured from special stel along with nuts,washer,anchor plate and common template.(iii)Supply of control gear boxes for non-integral flood light luminaries.(iv)Construction of shallow foundation with M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10T/sqm at 2 meter depth with all material and labour.(v)Erection of the High Mast with the help of suitable tools and plants,wiring of luminaries with all wiring material like PVC insulated PVC sheated flexible cable of suitable copper conductor cores of 2.5 sqmm, lugs, MCB and all labour complte all as specified and as directed. |
| 49 | Design, Fabrication,supply and installation of illluminated individual 3D acrylic letter(front lit) for the board reading as following.MILITARY ENGINEER SERVICESMAIN RECEIVING STATIONAGE (E/M) BASE HOSPITALCONSERVE TO PRESERVEThe work include providing and fixing 3D fabricated individual letter made from high quality acrylic and aluminium composite material ACP backing,complete with internal LED illumination in ED colour,suitable for outdoor installation.Each letter shall comprises front face 3mm cast acrylic sheet side 1.2mm thick SS 304 with back plate 2mm aluminum,powder coated with energy efficent waterproof LED modules with uniform light diffusion in red colour for 12 Volt dc LED driver concealed within the frame or a seprate junction box complte with wiring,connectors and necessary accessories for letter hight 200-300 mm complete in all aspect all as specified and as directed. |
| 50 | Design,Fabrication,Supply and Installtion of illuminated individual 3D acrylic (Front lit) for the main gate.The work include providing and fixing 3D fabricated individual MES symbol logo in dia made from high quality acrylic and aluminium composite material ACP backing,complete with internal LED illumination in Red colour, suitable foroutdoor installtion ,each shall comprises front face 3 mm cast acrylic sheet side-1.2 mm thick SS304 with back plate-2mm aluminum,powder coated with energy efficient waterproof LED modules (IP 65) with uniform light diffusion in RED colour for 12 Volt DC LED driver concealed within the frame or a seperate junction box complete with wiring,connectors and necessary accessories for dia of 300mm complete in all aspect all as specified and directed. |
| 51 | Supply and fix hinged door type IP 68 protected waterproof and tamper proofPole Mounted Distribution Box (Pole Box) suitable for street light made up of polycorbonate enclosure, size (378(w) x 235(H) x 429(D)) mm (outside) and size (337.8(w) x 206.5(H) x 321(D)) mm (inside) with minimum 1.5 mm wall thickness, for street light pole with necessary support (braket, clamps, U-bolts etc) required for fixing on the pole and equipped with(i) Lockable hinged door with neoprene gasket for dust and water ingress protection(ii)Provision for double earthing(iii)Cable entry Galnd (Both bottom and side entry)(iv)Internal Mounting Plate for electrical components(v) Neutral and Earth Busbar(vi)Protective coating: Anti corrosive, UV resistant powder coating suitable for harse environments(vii)Cable lugs and termination with ferrules and lebelling.The Box shall be securley insatlled at an appropriate height on the pole using galvanised mounting braket.Electrical circuit of the box comprising of copper bus bar 4 strips for 3 phase and neutral of rating 63 Amp supplied by 63 Amp MCB TPN including 10 Amp MCB, SPN,for controlling the street light fitting including connection ofPVCcopper stranded conductor cable, 2.5 Sqmm two core cable using suitable size of ferrule and lugs complete in all aspect including embossing/ painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face ofbox body complete including taking down old u/s KIOSK Box all as specified and as directed. Make:-Hensal Cat part no. UPC384323G or equivalent in Havells / Siemens / GENote:-Provision of 3.5 core LT Cable in pole box with suitable size of lug and ferrule deemed to be inclusive in quoted rate. Nothing extra in this regard shall paid to be contractor. |
| 52 | Material and labour for earthing complete with galvanised steel earth plate electorde of size 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.2 m below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to earth strip of size 32 x 6 mm earth lead by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 40 mm bore (light grade) and connected to earth test point and including cement concrete pit in PCC (1:3;6) type C-1(using 20 mm graded aggregate) and pre-cast RCC cover slab of size 540 x 540 x 50 mm thick with rain forced with 8 mm dia deformed bars both ways and one handle for lifing made with 10 mm dia mild steel bar,funnel, wire mesh 20 mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including necessary execuation and eath works in any types of soil complete all as shown on Electrical plate Nos 3 of MES Schedule Part I including taking out materials from existing on complete all as specified and directed. |
| 53 | Supply, fabrication, and delivery in replacement of an 11-meter height street light maintenance ladder, constructed from high-grade, lightweight, corrosion-resistant aluminum alloy. The ladder is suitable for safe maintenance of street light poles up to 11 meters in height and must comply with relevant safety and structural standards ,Telescopic type complete in all aspect made up of High-strength, extruded aluminum alloy (Grade 6061-T6 or approved equivalent),Anodized or powder-coated finish for corrosion resistance , Optional fiberglass sections incorporated for electrical insulation near energized equipment,having minium three interlocking section allowing smooth extension up to minimum high of 11 meter, antislip aluminium serrated aluminum rungs with rung spacing center to center 300mm, Side Rail“C” or “I” beam reinforced side members for structural rigidity with width between rail 400mm minimum ,rated for minimum 150 kg safe working load (SWL) tested to 1.5 times on SWL comply with IS : 4571 - 1977 (Reaffirmed 1995) standerd complete in all as specified and as directed. |
| 54 | M&L for painting on steel tubular Pole (of any height) for street light fittings including GI pipe/brackets fixed on poles, by applying two coats of synthetic enamel paint of aluminium colour including cleaning & preparingthe surface properly with sand paper including making strip with yellow/black/ white colour by using synthetic enamel paint of the required width as directed at site up to 1.5 metre height from ground level, writing numbers and letters by using radium paint with alphanumeric code of 3 inch in black in circle of yellow reflective background all as directed at site above 1.5 metre height from ground level complete all as specified and as directed. Note:Quoted Rate shall deemed to be Inclusive of Painting numbering of Poles after Painting work. |
| 55 | Supply and fix house service bracket ,hook type complete with 3.0M long GI Pipe 50mm dia medium grade, two Nos 90 degree bend MS hook and stay guard all as specified and as directed. |
| 56 | Supply and fix steel octagonal poles complete with cast iron base plate finial taper plug, bolts nuts and screw as specified type 410 SP 31 (09 meters) including two coat of synthetic enamel paint over a coat of red oxide paint internally & externally. (Note: Excavation cement concrete in foundation & coping shall be measured & paid separately unde relevant item of this Sch). |
| 57 | Cutting/trimming of tree branches around street light fitting up to 5 metre distance at all sides and disposal of debris out side MOD land complete all as specified and as directed. |
| 58 | M&L PCC type B-2 (1:2:4) with (using 40 mm graded aggregate) for Re-coping of existing street light pole including removal of damaged or deteriorated coping / concrete foundation, surface prepration,cleaning of base plate and anchor bolts, alignment and reinstalltion of new coping (using PCC) proper compaction, curing, finishing to original level and gradient and reinstatement of surrounding surface (e.g tile/ asphalt/ concrete / soil) to complete finishing all as specified and as directed. |
| 59 | S&F in replacement of constant current type LED street light driver, suitable for 45 watt to 70 watt LED Luminaries,designed to operate on 90 V-300 V AC ,50 Hz power supply, efficiency must greater than 85% and have a poer factor of 0.95,total hormonic distortion ofless than 10% complete in all aspect all as specified and as directed.Make:- Crompton/ Bajaj/ Surya/ Philips/ Havells |
| 60 | S&F in replacement of constant current type LED street light driver, suitable for 90 watt to 170 watt LED Luminaries,designed to operate on 90 V-300 V AC ,50 Hz power supply, efficiency must greater than 85% and have a poer factor of 0.95,total hormonic distortion ofless than 10% complete in all aspect all as specified and as directed.Make:- Crompton/ Bajaj/ Surya/ Philips/ Havells |
| 61 | S&F in replacement of constant current type LED Flood light driver, suitable for 90 watt to 120 watt LED Luminaries,designed to operate on 90 V-300 V AC ,50 Hz power supply, efficiency must greater than 85% and have a power factor of 0.95,total hormonic distortion ofless than 10% complete in all aspect all as specified and as directed.Make:- Crompton/ Bajaj/ Surya/ Philips/ Havells |
| 62 | S&F in replacement of constant current type LED Flood light driver, suitable for 120 watt to 200 watt LED Luminaries,designed to operate on 90 V-300 V AC ,50 Hz power supply, efficiency must greater than 85% and have a power factor of 0.95,total hormonic distortion ofless than 10% complete in all aspect all as specified and as directed.Make:- Crompton/ Bajaj/ Surya/ Philips/ Havells |