| 1 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations of poles etc. and getting outincluding trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 4 | Taking up/down old unserviceable GI/PVC/PPR pipes from trenches for repair including cleaning with all fittings of 150 mm bore complete all as specified and as directed by Engr-in-Charge. Note: Excavation/earth work will be measured and paidseparately under relevent item. |
| 5 | All as per item No 04 above here-in-before but of size 100 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 6 | All as per item No 04 above here-in-before but of size 80 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 7 | All as per item No 04 above here-in-before but of size 50 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 8 | All as per item No 04 above here-in-before but of size 40 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 9 | Supply and laying of new GI tube medium grade 150 mm bore with all fittings as required at site and laid in trenches incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 10 | All as per item No 09 above here-in-before but of size 100 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 11 | All as per item No 09 above here-in-before but of size 80 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 12 | All as per item No 09 above here-in-before but of size 50 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 13 | All as per item No 09 above here-in-before but of size 40 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 14 | Supply and laying of new PPR-C 63 mm bore triple layer (PN-16) with all fittings as required at site and laid in wall,floor etc incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 15 | Supply and laying of new PPR-C 50 mm bore triple layer (PN-16) with all fittings as required at site and laid in wall,floor etc incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 16 | Relaying of old serviceable GI pipe of 80 mm bore including fitting as obtained from item no - 06 in new or old position (trenches.) after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 17 | All as per item No 16 above here-in-before but of size 50 mm bore obtained from item no - 07 |
| 18 | All as per item No 16 above here-in-before but of size 40 mm bore obtained from item no - 08 |
| 19 | Taking up/down old unserviceable GI/PVC/PPR pipes from walls,floors,ceiling and duct etc for repair including cleaning with all fittings of 25mm bore complete all as specified and as directed by Engr-in-Charge. Note: Excavation/earth work will be measured and paidseparately under relevent item. |
| 20 | All as per item No 19 above here-in-before but of size 20 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 21 | Supply and laying of new GI tube medium grade 25mm bore with all fittings as required at site and laid in wall,floor etc incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 22 | All as per item No 21 above here-in-before but of size 20 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 23 | Supply and laying of new PPR-C 32 mm bore triple layer (PN-16) with all fittings as required at site and laid in wall,floor etc incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 24 | Supply and laying of new PPR-C 25 mm bore triple layer (PN-16) with all fittings as required at site and laid in wall,floor etc incl connecting with existing lines complete all as specified and as directed by Engr-in-Charge. |
| 25 | Relaying of old serviceable GI pipe of 25 mm bore including fitting as obtained from item no - 17 in new or old position (wall,floors.) after thorough cleaning of pipe (both sides) complete all as specified and directed. |
| 26 | All as per item No 25 above here-in-before but of size 20 mm bore obtained from item no - 18 |
| 27 | Supply and fixing of GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to ISincluding taking down old complete all as specified and as directed by Engr-in-Charge.Note: Union or long screw have to be provided before fixing of gate valve. |
| 28 | All as per item No 27 above here-in-before but of size 40 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 29 | All as per item No 27 above here-in-before but of size 25 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 30 | All as per item No 27 above here-in-before but of size 20 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 31 | All as per item No 27 above here-in-before but of size 15 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 32 | Taking down unserviceable sluice valve/NRV/foot valve and their fitments like gasket , bolt/nuts of size upto 300 mm bore without damaging the valve chamber and pipe line complete all as specified and as directed by Engr-in-Charge. |
| 33 | Supply and fixing sluice valve 150 mm bore, ISI marked, as per IS 14846: 2000 , with valid CMLNo. , Batch No. and Manufacturer Serial No.,class PN 1.6 with brass spindle, brass check nut, with fiber board gasket, bolts, nuts and washers for fixing the valvein position, in valve pit chambers or location as directedand specified by Engr-in-charge. Make Uphadhya / Kirloskar/ LeaderNote : Contractor hasto submit the test certificate and Purchase Voucherof valves before claiming the payment.. |
| 34 | All as per item No 33 above here-in-before but of size 100 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 35 | All as per item No 33 above here-in-before but of size 80 mm bore, complete all as specified and as directed by Engr-in-Charge. |
| 36 | Supply and fixing Non rerturn sluice valve with brass spindle, gasket, bolts, nuts and washers in position of 150 mm bore in valve pit chambers or near to bore well complete all as specified and as directed by Engr-in-Charge. |
| 37 | Supply & fix MS column pipe 100 mm dia bore, heavy duty, 10 feet long each with flanges screwed and welded both ends complete with nuts , bolts , gasket etc for jointing pipe and lowering into bore wellincl taking up/down old u/s any type complete all as specified and directed by Engr-In-charge. |
| 38 | Supply and fixing GI column pipe 50 mm dia bore, heavy class ,cut 10 feet longwith long thread at both side including supply of heavy duty sockets on both end for jointing the pipesand lowering into bore well incl taking up/down old u/s complete all as specified and directed by Engr-In-charge. |
| 39 | Supply and fix only PVC coated steel wire rope 10mm dia with U clamps of suitable size securing the submersible pump motor and taking out old unserviceable complete all as specified and as directed by Engr-in-Charge. |
| 40 | Supply and fix only PVC insulated & sheathed Submersible flate cable 6 Sqmm x 3 core copper conductor 1100 volt grade, ISI Marked, confirming to IS:694/2010, and taking out old U/S complete all as specified and as directed Engr-in-Charge. |
| 41 | Supply and fix only PVC insulated & sheathed Submersible flate cable 4 Sqmm x 3 core copper conductor 1100 volt grade, ISI Marked, confirming to IS:694/2010, and taking out old U/S complete all as specified and as directed Engr-in-Charge. |
| 42 | (a)Lifting of defective submersible Sewage pump set of any make and capacity 10HP fromafter providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuse after preparation of pump external surface complete all as specified and directed.all complete and (b) Lowering of repaired /overhauled/rewinded submersiblepumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete. (Note : Parts will be paid separately under appropiate item) |
| 43 | M & L for rewinding of burnt submersible pump set of any make and capacity up to 10 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed. |
| 44 | Supply & fix Rotor shaft with couplings and seals of submersible motor of capacity 10 HP (as per OEM) and taking out old u/s item complete all as specified and directed.Make : As per OEM and ISI Marked. |
| 45 | Supply & fix thrust bearing of submersible motor of capacity of 10HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 46 | Supply & fix Impeller of submersible motor of capacity of 10HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 47 | Supply & fix diffuser of submersible motor of capacity of 10HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge. |
| 48 | Supply & fix neck ring of submersible motor of capacity 10HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 49 | Supply & fix stud nut of submersible motor of capacity of 10HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 50 | (a)Lifting of defective submersible pump set of any make and capacity 20 HP fromafter providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuseand Comprehensive maintenance as per Original Equipment Manufacturer\"s (OEMs) reccommendationsinstalled at various locations after preparation of pump external surface complete all as specified and directed.all complete and (b) Lowering of repaired /overhauled/rewinded submersiblepumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines with new rubber gasket 3 mm thick, nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete. (Note : Parts will be paid separately under appropiate item) |
| 51 | M & L for rewinding of burnt submersible pump set of any make and capacity up to 20 HP, 3 phase ,415 V, 50 Hz of any make with water proof insulated copper conductor of the same specification as per old one after dismantling / cutting out burnt windings from stator assembly, cleaning slots properly complete with insulating slots packing, sleeves, papers & reassembling stator and rotor after replacement of worn out spares/matching works after preparation of motor external surface and water proof jointing for submersible cable 3 core, with replacement of oil seal, sand guard, bolt gasket, cable packing ring, circlip, bearing bush upper & lower etc. complete as specified and directed. |
| 52 | Supply & fix Rotor shaft with couplings and seals of submersible motor of capacity 20 HP (as per OEM) and taking out old u/s item complete all as specified and directed.Make : As per OEM and ISI Marked. |
| 53 | Supply & fix thrust bearing of submersible motor of capacity of 20HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 54 | Supply & fix Impeller of submersible motor of capacity of 20HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 55 | Supply & fix diffuser of submersible motor of capacity of 20HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply & fix neck ring of submersible motor of capacity 20HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 57 | Supply & fix stud nut of submersible motor of capacity of 20HP and taking out old u/s item complete all as specified and directed by Engr-in-Charge.Make : As per OEM and ISI Marked. |
| 58 | (a)Lifting of defective submersible pump set of any make and capacity 1.5 HP fromafter providing lifting tools , chain pulley etc. as required carefully, by disconnecting/dismantling all electric connections, column pipes, steel ropes/chain and keeping them under safe custody for reuseand Comprehensive maintenance installed at various locations after preparation of pump external surface complete all as specified and directed.all complete and (b) Lowering of repaired /overhauled/rewinded submersiblepumping set of any make and capacity after proper coupling of pump and motor , fixing old/new chain with clamp, connecting/refixing existing/new column pipe lines nuts, bolts & washers carefully with the help of chain pulley etc. & carefully re-connecting all electric/water lines and testing on load to the entire satisfaction of Engineer-in-charge complete. (Note : Parts will be paid separately under appropiate item) |
| 59 | Supply, installation, testing and commissioning of submersible pump set of capacity 1.1 KW/ 1.5 HP, 1 phase, 50Hz, 2800 - 3000 RPM, 4 stage , Dicharge range not less than 80 LPM,220 - 240 Volt operating voltage, IP58, outlet size 32mm,with suitable motor starter including testingcomplete all as per Make Kirloskar/KSB/Crompton complete and including dismantling existing pump set completeall as specified and as directed by Engr-in-Charge. Make - Kirloskar/KSB/Crompton/CRI(Note - Old U/s existing submersible pump shall be dismantled and to be deposited in MES store yard as directed by Engr-in-charge) |
| 60 | M&L for dismantling/disconnecting of Openwell submersible/ Monoblock Centrifugal pumpset with electric drivencapacity 5 HP, 3- phase, 415 volts, 50 Hz from suction and delivery pipe and removing from existing position and repair/rewinding and replacement of sleeves & core packing, bushing complete and refixing on same position incl connecting testing all as specified and directed by Engr-in-Charge. |
| 61 | S & F MCCB 125 Amps current capacity four pole and breaking capacity 36KA at 415V on existing LT panel incl taking down old unserviceable MCCB complete all as specified and as directed. |
| 62 | M&L forPCC (1:4:8) type D2 using 40 mm graded stone aggregate as in motor foundation, filling and massconcrete including demolation of concrete of any descriptioncomplete all as specified and directed by Engr-in-Charge. |
| 63 | M&L for rendering 10 mm thick on stone or block masonry wall with cement morter 1: 4 including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 64 | Material and labour forrun lead joints for connecting of the CI pipes of 300 mm dia of pipe including jointing materials and including burning out lead jointscomplete all as specified and directed. |
| 65 | Material and labour forrun lead joints for connecting of the CI pipes of 200 mm dia of pipe including jointing materials and including burning out lead jointscomplete all as specified and directed. |
| 66 | Material and labour forrun lead joints for connecting of the CI pipes of 150 mm dia of pipe including jointing materials and including burning out lead jointscomplete all as specified and directed. |
| 67 | Material and labour forrun lead joints for connecting of the CI pipes of 100 mm dia of pipe including jointing materials and including burning out lead jointscomplete all as specified and directed. |
| 68 | Material and labour forrun lead joints for connecting of the CI pipes of 80 mm dia of pipe including jointing materials and including burning out lead jointscomplete all as specified and directed. |
| 69 | M&L for framedworkfor valve pit chamber cover made of Mild steel (MS) equal angle and MS sheet2.8 mm thick including welding , cutting ,hinges , locking arrangments , painting including dismantling wrought iron or mild steel work of any description provided for valve pit chamber and for angle iron ladder of tank complete with and including two coat synthethic enamel paint high glossy finish, of Make Asian Apcolite rust shield , Anti rust shield PU enamel over a coat of primer complete all as specified and directed |
| 70 | Supply and fix short piece MS pipe heavy duty, min thickness 6 mm, of min length 1.0 mtr, 100 mm dia having one end welded and screwedwith MS flange having 4 or 8 hole and grove for passing of submersible cable and wire rope and other side with thread end having 8 pitch incl taking out ols unsv complete all as specified and directed |
| 71 | M & L for brick work with sub class ‘B’ bricks, straight or curved on plan to exceeding 6m mean radius, built in 1:4 cement mortar including demolation of brick work of any description complete all as specified and directed by Engr-in-Charge. |
| 72 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth stripcomplete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. |
| 73 | Material and labour for fixing of Ductile Iron special fittings(Bends any type, radius an angle Tapers any type,straight, bend, increasing, decreasing or double socket etc. Tee pieces single branch, `Y\" junction, double branch, cross) all socket and spigot collars type, caps and plugs up to 200 mm dia as per site requirement, complete all as specified and as directed by Engr-in-Charge. |
| 74 | Supply and fix of rubber sheet of min 3 mm thickness for use in jointing sulice valves with flange etc complete all as specified and directed by Eng in charge. |
| 75 | Supply only MS nut bolt and washer of size as specified complete all as specified and directed by Eng in charge. |
| 76 | Supply only U clamp heavy duty for steel wire rope clamping all as specified by EIC. |
| 77 | Supply only Bib taps, PVC of size 15 mm dia, ISI marked,complete all as directed . Make-Prayag Cat No 121-0 or equivalent make. |
| 78 | Material and labour for cleaning of complete sludge collection chambers with partition wall of Sewage sump No.1 at Camp I of size 6 mtr x 3 mtr x 4.5 mtr (Inside sump) and size 10 mtr x 1.85 mtr x 5.5 mtr (out side sump) by pumping out fluid and taking out sedimented sludge using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land in closed covered containerandpainting of inside wall of sump and chamber withtwo coat black bituimious paint after preparartion of surfaces and two coat white wash on out side exposed wall exposed externaly,complete all as specified and as directed by Engr-in-charge. |
| 79 | Material and labour for cleaning of cylindrical sludge collection chamber of Sewage sump No. 2 at Camp II of size 4 mtr dia x 6 mtr depthby pumping out fluid and taking out sedimented sludge using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land in closed covered containerandpainting of inside wall of sump and chamber withtwo coat black bituimious paint after preparartion of surfaces and two coat white wash on out side exposed wall exposed externaly,complete all as specified and as directed by Engr-in-charge. |
| 80 | Material and labour for cleaning of complete sludge collection chambers of Sewage sump No.3 at NCE area of Size 7.5 mtr dia and 6 mtr depth by pumping out fluid and taking out sedimented sludge using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land in closed covered containerandpainting of inside wall of sump and chamber withtwo coat black bituimious paint after preparartion of surfaces and two coat white wash on out side exposed wall exposed externaly,complete all as specified and as directed by Engr-in-charge. |
| 81 | Material and labour for cleaning of cylindrical sludge collection chamber of Sewage pump house No. 4 at SV area near Golf ground of size 4.0 mtr dia x 6 mtr depth by pumping out fluid and taking out sedimented sludge using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land in closed covered containerandpainting of inside wall of sump and chamber withtwo coat black bituimious paint after preparartion of surfaces and two coat white wash on out side exposed wall exposed externaly,complete all as specified and as directed by Engr-in-charge. |
| 82 | Material and labour for cleaning of complete sludge collection chambers of Sewage pump house No.5 at SV area of Size 14 mtr x 6 mtr x 6 mtr by pumping out fluid and taking out sedimented sludge using the cleaning devices as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing the sludge and solid contents outside MD land in closed covered containerandpainting of inside wall of sump and chamber withtwo coat black bituimious paint after preparartion of surfaces and two coat white wash on out side exposed wall exposed externaly,complete all as specified and as directed by Engr-in-charge. |
| 83 | Supply only bleaching powder, grade 1 as per IS 1065: 1989, minimum 35 percent chlorine available by mass, 1/15 max loss of chlorine on the basis of initial available chlorine, 99.5 percent minimum particle size by mass all as specified. |
| 84 | Supply only Pool Clarifier 2050, colorless yellow liquid suitable for water treatment to clear water as a flocculant for swimming pool/ Treatment plant and delivered to AGE (E/M) store yard as specified and directed by Engineer-in-Charge. Make : ISI marked or any make or brand approved by Garrison Engineer. |
| 85 | Supply only WD-40, multipurpose spray for rust removal of capacity 420 ml complete all as specified and as directed by Engr-in-Charge. |
| 86 | Testing of water sample from PHE Kharagpur Division, sample collected (fresh water from borewell) from all serviceable borewell (14 Nos), swimming pool on various parameter (PH value, TDS,Turbidity, Total Hardness, Iron, Magenese, Total Coliform bacteria, E coil thermotolerant). Testing of sample done only after the direction of Engr-in-Charge. |
| 87 | M & L air compressor of borewell from OEM, borewell size upto 300mm dia , giving suitable air pressure with suitable timing, expert and experience technician will operate the whole process upto 12 hours with complete statisfaction with clear water coming out from borell all as specified and directed by Engr-in-charge.Note - (i) All T&P item required for this operation will arrange by the contractor. (ii) He will be responsible for gate entry and gate exist of tecnician during operation. (iii) Required Diesel Qty arranged by the contractor and it will be included in quoted rate. |
| 88 | Material and labour for cleaning and washing of inside portion of RCC overhead reservoir round/square typeof capacity 1.10 lakhs gallons including removing of sand /mud and fungus formation etcwith wire mesh brush, bleaching powder and deposited to 50 mtr away from the O/Tand white wash the total inside the tank and write cleaning date and due date. All as specified and directed by Engr-in-charge.Note :- Following work amount will be deemed to be included in the unit quoted rate ( No extra payment will be given to contractor )1. Drain out the water by using exit valve or own high capacity dewatering system.2. Fresh water cleaning by high pressure jet pump.3. Cleaning the floor of the water tank by industrial vaccum cleaner. |
| 89 | All as per item No. 88 here-in-before but capacity 60000 gallons at domestic area complete all as specified and as directed |
| 90 | All as per item No. 88 here-in-before but capacity 25000 gallons at technical area complete all as specified and as directed |
| 91 | All as per item No.88 here-in-before but capacity 20000 gallons at technical area complete all as specified and as directed |
| 92 | All as per item No.88 here-in-before but capacity 15000 gallons at technical area complete all as specified and as directed |