| 1 | Excavation in trenchesin hard/ densesoil n. exc 1.5m wide and n. exc 1.50m deep and getting out complete all as specifiedand directed |
| 2 | M&L for PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in foundation, mass concrete for stay set/ Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement, complete all as specified and directed. |
| 3 | S&F for Mild steel bars 10mm dia TMT bar and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 4 | S&F Mild steel bars 5mm and over upto and including 10mm dia in stirrups spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 5 | S&F angle iron as in posts and struts for fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290, gde E-165, complete all as specified and directed. |
| 6 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpaas in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 7 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc., (each line wire to be measured), complete all as specified and directed. |
| 8 | M&L for Punched tape concertina coil 610 mm dia, made out of 2.60 mm dia ( + 0.05 mm) high tensile spring steel wire (1620 MPA) withhaving zinc coating of 120 gms/Sqm as per IS: 228. Each coil having a min 50 turns (Circles), average weight 7.50 to 8 Kg ( + )5% including handle and spikes at both ends of coil errect and fixed on top of the \"Y\" Shape fencing, tied to the barbed wire/ angle iron with suitable GI binding wires, complete all as specified and directed. Specifications: Diameter: 610 mmNo of Rounds: 50 roundsStretch of each coil: 6-8 meterTotal length of straight wire in each coil: 94.26 Meterbarb Length (mm): 11.50 mm ( + 2.00 mm)Weight of each coil: 7.50 to 8 Kg |
| 9 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed. |
| 10 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions incl fair finishes of surfaces, complete all as specified and directed. |
| 11 | M&L for for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed. |
| 12 | M&L for RCC M-25 (design mix) as in foundation of column footings Plinth Beam, bases for column, basement slab etc using 20mm graded stone aggregate, complete all as specified and directed. |
| 13 | M&L for RCC M-25 (design mix) as in column, pillars, piers, posts & struts using 20mm graded using 20mm 20mm graded stone aggregate, complete all as specified and directed. |
| 14 | M&L for RCC M-25 (design mix) using 20mm graded stone aggregate as in beams cantilevers bressumers lintels over 1.5m span etc., complete all as specified and directed. |
| 15 | M&L for old size brick work with sub class \"B\" briick straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed. |
| 16 | M&L for rendering 15mm thick wall plaster in cm (1:4) on fair faces of brick work or concrete surfaces including finished even & fair without using extra cement with WPC, complete all as specified and directed. |
| 17 | M&L for preparing new plastered surfaces of walls with two coats cement base paint on wallls over a coat of alkali resistant paint, complete all as specified and directed. |
| 18 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick in each layers, complete all as specified and directed. |
| 19 | Removing excavated material n exc 50m and depositng where directed at a level n.exc 1.5m above the starting point (ncl filling in floor) for any type of soil, complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4, type B-0, using 12.5mm coarse aggrgate for bands, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 21 | M&L for Broken glass coping on top of boundarywalls in cement mortar 1:3, complete all as specified and directed. |
| 22 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed.Note: Width up to 1.20 mtr of chain link fence. |
| 23 | Supply only chain link MS galvanised fencing, of size 4mm(8 SWG) 50x50mm, complete all as specified and directed. |
| 24 | Removal of vegetation, cutting and uprooting of Trees/ plants/ bushes/ shrubs growing over wall, of any position and any location. Including cutting of brick work or concrete in position not exc 1 sqm in area and applying chemical biocide treatment such as biocycle Glycel \"or other chemical as approved by GE including making good the surfaces with PCC 1:2:4, type B-0, using 12.5mm graded crushed stone aggregate and finishing with 15 mm thick plaster in CM 1:4, complete all as specified and directed. |
| 25 | S&F 110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and directed. |
| 26 | M&L for preparation of new steel surfaces of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of redoxide primer, complete all as specified and directed. |
| 27 | Excavating in trenches, n exc1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out for soft soil, complete all as specified and directed. |
| 28 | M&L for providing plain cement concrete 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete, for stay set/ Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement, complete all as specified and directed. |
| 29 | M&L for PCC 1:2:4, type B-2, using 20mm graded crushed stone aggregate as in surface channels, benching etc., laid to shape and slope including all formwork etc., complete all as specified and directed. |
| 30 | M&L for brickwork with old size sub class `B\" bricks, straight or curved on plan exc. 6.00m mean radius, built in CM 1:4, complete all as specified and directed. |
| 31 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/ stopped ends etc.(for saucer drain), complete all as specified and directed. |
| 32 | Add to or deduct from item No. 31.00 above for each 25 mm girth or part thereof over or under 30 cm inner girth, complete all as specified and directed. |
| 33 | M&L for providing pre-cast reinforced cement concrete( Factory made MD-10) landing, manhole covers and similar items with plain faces in cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate and setting in CM 1:4 with and including necessary formwork, complete all as specified and directed. |
| 34 | S&F steel tubular pole 9 metre, 410 SP-31swan neck with base plate, bolts, nuts & screws, complete all as specified and directed. Make: Vikram Industries/ Shivam Metal Shapers, Surya, HPL or equivalent as approved. |
| 35 | S&F LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection, complete all as specified and directed. |
| 36 | S&F 1.5 sqmm 3 Core, PVC insulated and FR PVC round sheathed copper conductor flexible 1100 voltsfor connection from OH Line to street light fittings, complete all as specified and directed. |
| 37 | Supply, laying and testing cable XLPE insulated,screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, complete all as specified and directed. |
| 38 | S&F street light pole cable junction box IP-66 size should be not less than 155x210x92 mm (upto Cable Size 10/16sqmm) with the box made out of thermal plastic (Thermoplastic Polycarbonate) material suitable for 10/16 UG sqmm cable. The JB shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive, IP 65 in accordance with IEC 60529, weatherproof UV-resistant, rainwater-proof, temperature-resistant. The impact strength of Polycarbonate enclosure/ boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08 including one No. 4 pole connector and one no.MCB SP6Ampand chromium plated clamps, suitable cable gromets and nut bolts, complete all as specified and directed.Make: Cat Part: DK 1616 G/ 1600G of Hensel/ Siemens/ Schneider/ ABB. |
| 39 | S&F solar all in one street light with compact ABS housing with Life P04 battery with charge time 6-8 hrs & discharge time 10-12 hrs, 4.5 V polycrystalline solar PV panel with lumianarie, microwave motion sensor, high lumen output of 4000lm in 25W, fixing and connection, complete all as specified and directed. |
| 40 | M&L for octagonal pole 6 Mtr long suitable for fixing of motion sensor light complete all as specified and directed. Make: Crompton/ Bajaj/ Jindal or as equivalent as approved. |
| 41 | S&F GI Bracket canopy type 1 mtr arm for Octagonal pole for street light fitting complete with MS clamps duly painted with two coat of aluminum paint with nuts/ bolts/ washers for fixing arrangement to pole/ wall, complete all as specified and directed. |
| 42 | Removing of surplus soil (soft/ loose) obtained from excavation to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point, complete all as specified and directed. |
| 43 | M&L for dry and clean fine sand for cable cushioning for cable protection complete all as specified and directed.Note: Punned down thickness shall be measured. |
| 44 | Supply and laying well burnt old size sub class \"B\" bricks laid in trenches for cable protection, complete all as specified and directed. |
| 45 | M&L for PCC 1:2:4, type B-1,using 20mm graded crushed stone aggregate as in coping of pole including necessary form work as required, complete all as specified and directed. |
| 46 | Supply and laying GI pipe light grade 40mm dia with all fittings for cable protection, complete all as specified and directed. |