| 1 | Dismantling and taking out the existing corroded / scaled GI pipe / PPR/ PALP pipe with fittings connectionsfrom trenches, walls, ceiling or floor andremoval from site or disposed off for the following sizes complete all as specifed and directed.Note: Excavation and earth work shall be measured and paid seperately under respective item of schedule \"A\" |
| 2 | 20 mm bore |
| 3 | 25 mm bore |
| 4 | 40 mm bore |
| 5 | 50 mm bore |
| 6 | 80 mm bore |
| 7 | Refixing of old GI tubing in new or old position (walls, ceiling, floors and trench etc) for the following size complete all as specified and directed. Note: Excavation and earth work shall be measuered and paid seperately under respectiveitem of schedule \"A\" |
| 8 | 20 mm bore |
| 9 | 25 mm bore |
| 10 | 40 mm bore |
| 11 | 50 mm bore |
| 12 | 80 mm bore |
| 13 | Supply, laying, fixing & testing galvanished iron watertubing \"medium grade; with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducingbends , elbows, tee, checkneuts, caps, plugs etc laid in trenches for the following sizes complete all as specifed and directed. Note: Excavation and earth work shall be measuered and paid seperately under respectiveitem of schedule \"A\"Make : TATA/Surya Prakash/Jindal |
| 14 | 20 mm bore |
| 15 | 25 mm bore |
| 16 | 40 mm bore |
| 17 | 50 mm bore |
| 18 | 80 mm bore |
| 19 | Supply, laying, fixing & testing galvanished iron watertubing \"medium grade; 20 mm bore ISI marked with and inclduing all GI fittings such as flanges, unions reducers sockets, socket reducingbends , elbows, tee, checkneuts, caps, plugs etc fixed to wall, lain in floors for the following sizes complete all as specifed and directed. Make: TATA/Surya Prakash/Jindal |
| 20 | Supply and fixing straight through joint complete with jointing materials suitable for three core stranded copper conductor cable for 120 to 240 Sqmm 3.50 core cable 1100 Volt gradeall as specified and directed. |
| 21 | Supply and fixing of cast iron specials /DI fittings ISI marked for pressure water mains 200mm dia and upto 300mm bore spigot and socket Tee pieces, single or double brunch connection or collar etc. including dismantling of old CI fittings complete all as specified and directed. Note : Excavation and earth work shall be measured and paid for separately. |
| 22 | Supply and fixing of CI fitting / DI fittings for spigot & socket end pipes such as Bends (any type, radius and angle), Tapers any type (Straight, bend, increasing, decreasing or double socket etc), Tee pieces single branch, `Y` junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs andmechanicaljoints any type etc upto 150 mm bore including dismantling of old CI fittings complete all as specified and directed. |
| 23 | Material and labour for cutting ofcast iron pipe mains 200 mm bore for insertion of tees, collars, sluice valves, etc including dewatering work required for working water pipe lines complete all as specified and directed. |
| 24 | Description all as per item No 8 above but 150 mmbore. |
| 25 | Description all as per item No 8 above but 100 mmbore. |
| 26 | Material and labour for cutting the existing hard standing/ metal road of facilitate for laying of water pipe line and making good the disturbed portion to bring it to original condition with plain cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) complete all as specified and as directed. |
| 27 | Supplying, laying and testing of DI pipe 200 mm bore, with spigot and socket end, class K9ISI marked as per IS 8329 laid in trenches etc complete all as specified and directed. Make: Electrosteel/TATA/JINDAL |
| 28 | Description all as per item No 12 above but 150 mmbore. |
| 29 | Description all as per item No 12 above but 100 mmbore. |
| 30 | Excavation in trenches in any type of soil not exceeding 1.5 Meter wide and not exceeding 1.5 Meter deep in any type of soil including cutting in slopes etc for laying of pipe line including getting out, complete all as specified and directed. |
| 31 | Returning, filling in, including spreading, leveling, watering and well ramming in layers in soft / loose soilnot exceeding 25 cm in each layer complete all as specified and directed. |
| 32 | Removal of excavated material (Soil) to a distance up to 50 Meter from starting point and depositing where directed at level not exceeding 1.5 Meter above as directed. |
| 33 | Supply and fixing of cast iron \"D\" joint set complete of two flanged collar one no sleeve two nos rubber \"O\" ring and nut bolts washers of suitable size for 200 mm bore CI/DI pipe complete including necessary cutting, grinding work to fix in pipe as directed. (Note:- Earth work required to clear the existing pipe line shall be measured and paid separately) |
| 34 | Description all as per item No 18 above but 150 mm bore |
| 35 | Description all as per item No 18 above but 100 mm bore |
| 36 | Description all as per item No 18 above but 80 mm bore |
| 37 | Supply and fixing in replacement of CI sluicevalve,both end flanged with stainlesssteel spindle (Riising spindle) as per IS:14846/2000, PN - 1.6, with hand wheel, ISI marked of following sizes :- |
| 38 | 200 mm bore |
| 39 | 150 mmbore |
| 40 | 125 mm bore |
| 41 | 100 mm bore |
| 42 | Supply and fixing in replacement of CI sluicevalve,both end flanged dully drilled for both ends with stainlesssteel spindle (Non riising spindle) as per IS:14846/2000, PN - 1.6, with hand wheel, ISI marked of following sizes |
| 43 | 300 mm bore |
| 44 | 250 mmbore |
| 45 | 200 mm bore |
| 46 | 150 mm bore. |
| 47 | 100 mm bore |
| 48 | 80 mm bore. |
| 49 | Supply and fixing CI Non return valvein replacement,flanged ends as per IS-5312 complete with Nuts/Bolts and washers and rubber packing etc forthe following sizes:- |
| 50 | 300 mm bore |
| 51 | 200 mm bore |
| 52 | 150 mm bore |
| 53 | 125 mm bore |
| 54 | Dismantling and taking out old unserviceable foot valve any type and supply and fixing new CI ball foot valve, one end flanged and strainer to the other side for the following sizes:- |
| 55 | 80 mm bore |
| 56 | 100 mm bore |
| 57 | 125 mm bore |
| 58 | 150 mm bore |
| 59 | 200 mm bore |
| 60 | 250 mm bore |
| 61 | Dismantle the existing damaged glow sign board complete from the entrance gate of Pump House and remove from site.Supply & installation Glow Sign board made out of PGI sheet 1 mm thick fixed with transparent PVC acrylic sheet cover of thickness 2.5 mm, of colour as directed with letters and digits of approx size 25 x 10 CM , of colour as directed,fixed with and including 18 watts, 240 Volt LED tube light fitting with rods as required at site connecting with existing electrical point using 2 core PVC insulated, 1.5 Sqmm PVC insulated and PVC sheathed stranded copper conductor cable of suitable length with switch, fixing the sign board on GI pole/buildingusing necessary fixing arrangements viz clamps, nuts, bolts and washers and welding , excavation and PCC work all as specified and directed.Note :1. Size of sign board and colour will be decided by the department as per the site requirement. |
| 62 | Material and labour for site clearance by means removing of debris, cutting of grass, bushes, plant growth and disposed off up to a distance not more than 50mtr from the starting point all as directed at site at various water supply installations complete all as directed. |
| 63 | Supply , installation, testing and commissioning of indoor type,weather proof, LT Panel made out of 2 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 45 x 45 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flowsuitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricatedwith suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated andprewired as per standard engineering practice, suitable cable glands for cable entry including dismantling existing panel of any type complete all as specified and directed. The panel shall be suitable to accomodate the following equiptments :-(a)Copper bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for Phases neutral - 01 set (b)Phase indicating lamp neon/LED type (Red ,Yellow &Blue) with lamp holders - 03 Nos(c)Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job(d)Digital multifunction meter of size 96x96 mm to measure current, voltage, frequency and power factor with built in selector switch. Incoming :-(a) Onload changeover switch 400 Amp, 4 pole,415 Volts - 01 No. (b) MCCB 400 Amp, 4 pole, 35/36 KA, 415 Volts, Adjustable thermal and adjustable magnetic setting with extended terminals, Ics=100% of Icu - 01 No.Outgoing :-(a) MCCB 4 pole , Ics=100%Icu- 25KA, 415 Volts, 160 Amps , Adjustable thermal and adjustable magnetic setting with extended terminals -02 Nos.(b) MCCB 4 pole , Ics=100%Icu- 25KA, 415 Volts, 125 Amps , Adjustable thermal and adjustable magnetic setting with extended terminals -02 Nos.(c) MCCB 4 pole , Ics=100%Icu- 25/26 KA, 415 Volts, 32 Amps , Adjustable thermal and adjustable magnetic setting with extended terminals -1Nos.(d)Fully automatic star delta starter of 75 HP cap with D range contactor,LRID OLR & electronic star delta timer with start/stop push botton , with relay range 45 A-65 A Amps with inbuilt voltmeter and ampere meter, RYB indicator lampscomplete all as specified and directed, make-L&T - 02 Nos(e)Fully automatic star delta starter of 50 HP cap with D range contactor,LRID OLR & electronic star delta timer with start/stop push botton , with relay range 45 A-65 A Amps with inbuilt voltmeter and ampere meter, RYB indicator lampscomplete all as specified and directed, make-L&T - 02 Nos(f) PCC 1:3:6 type C-2 for grouting 4 legs of LT PanelNote :-(i) Rates quoted by the contractor shall be deemed toinclude for:- (ii) Connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (iii) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed. |
| 64 | Dismantling of unserviceable sluice valve of 150 mmsize from water pipe line forrepair and openingand greasing complete parts, all parts cleaned by Kerosene oil neatly with and including replacement of defective spare parts by news parts including necessary welding machine/ grinding work if required at the time of refitting of spare into sluice valve and refixing on existing water pipe line and testing on full discharge complete all as specified and directed.Note:- (i) Cost ofSpare parts which are required to be replaced during repair shall be deemed to be included in the quoted rates of this item. (ii) During repair of unserviceable sluice valve one functional sluice valve of same size shall be fixed (without any extra cost) at the place of u/s sluice valve at site for smooth functioning of water supply system and contractor will ensure that no water supply breakdown happened at site. |
| 65 | Brass Spindle suitable for 150 sluice valve |
| 66 | Seat with seat ring suitable for 150 sluice valve |
| 67 | Gland packing suitable for 150 sluice valve |
| 68 | Dismantling of unserviceable sluice valve of 200mm to 300 mmsize from water pipe line forrepair and openingand greasing complete parts, all parts cleaned by Kerosene oil neatly with and including replacement of defective spare parts by news parts including necessary welding machine/ grinding work if required at the time of refitting of spare into sluice valve and refixing on existing water pipe line and testing on full discharge complete all as specified and directed.Note:- (i) Cost of minor parts (below Rs 100/each) shall be deemed to be included in the quoted rates of this item. (ii) During repair of unserviceable sluice valve one functional sluice valve of same size shall be fixed (without any extra cost) at the place of u/s sluice valve at site for smooth functioning of water supply system and contractor will ensure that no water supply breakdown happened at site. (iii) Rate of spare parts (Rate above Rs100/-each) required for repair the sluice vlave shall be measured and paid separately. |
| 69 | Brass Spindle suitable for 250mm to 300mm sluice valve |
| 70 | Seat with seat ring suitable for 250mm to 300mm sluice valve |
| 71 | Gland packing suitable for faulty 250mm300mm sluice valve |
| 72 | Supply and fixing in replacement of u/s MCCB 250 Amps with terminals,thermal magnetic, breaking capacity 36 KA 4 pole 415 V AC 50 Hz complete all as specified and directed. |
| 73 | Supply and fixing in replacement of u/s MCCB 200 Amps with terminals,thermal magnetic , breaking capacity 36 KA 4 pole 415 V AC 50 Hz complete all as specified and directed. |
| 74 | Supply and fixing in replacement of u/s MCCB 160 Amps with terminals,thermal magnetic, breaking capacity 36 KA 4 pole 415 V AC 50 Hz complete all as specified and directed. |
| 75 | Taking down old wire mesh opening fixed with Semi Underground Water Storage Sumpat various water supply installations and Material and labour for fixing new wire mesh opening (size and type as per existing) alongwith MS frame properly fixed with RCC sump structure of semi underground water storage sump of capacity from 25000 Gln to 100000 Gln complete all as specified and as directed. |
| 76 | Supply, laying and testing of MS ERW steel pipe 7.00 mm thick of 200 mm dia ncluding taking down etc complete all as specified and and directed. |
| 77 | Supply, laying and testing of MS ERW steel pipe 7.00 mm thick of 150 mm dia ncluding taking down etc complete all as specified and and directed. |
| 78 | Material and Labour MS flange min 8.00 mm thick of 200 mmdia duly drilled holes including welding in plain end of MS Pipe with one rubber gasket. |
| 79 | Material and Labour MS flange min 8.00 mm thick of 150 mmdia duly drilled holes including welding in plain end of MS Pipe with one rubber gasket. |
| 80 | Supply and fixing of cast iron MJ Collar set complete of two flanged collar one no sleeve two nos rubber \"O\" ring and nut bolts washers of suitable size for 300 mm bore CI/DI pipe complete including necessary cutting, grinding work to fix in pipe complete all as directed. (Note:- Earth work required to clear the existing pipe line shall be measured and paid separately) |
| 81 | Description all as per item No 39 above but 200 mm bore |
| 82 | Description all as per item No 39 above but 150 mm bore |
| 83 | Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 240 Sqmm 3.5 core in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete including taking down existing cable complete all as specified and as directed.Note :-HDPE DWC pipe(Protection Pipe) shall be measured and paid seprately under respective item of Schedule A. |
| 84 | Material and labour for HDPE DWC Protection Pipe of internal dia minimum 90mm , including necessary clamps for the protection of the cable fixed to wall, floor, along pole etc complete all as specified and directed. |
| 85 | NOTE:- Amount of credit ofRs. 81205.00 for retrieved materials is mentioned in Schedule of Credit Page No21 of tender documents in pdf form which will be deducted offline while acceptance of tender. |