|
| 1 | Surface dressing not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Excavation of mud/soft/loose soils in trenches not exc 1.50mwide and not exc 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, drain, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth including any type old pipe and getting out complete all as specified and directed. |
| 3 | Excavation of hard/dense soils in trenches not exc 1.50mwide and not exc 3.00m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 3.00 m in depth including any type old pipe and getting out complete all as specified and directed. |
| 4 | Returning, filling in including spreading leveling, watering and wellramming in layers not exc 25 cm of soil all as specified & directed. |
| 5 | Removing surplus soil to a distanceexceeding exc. 1.50 km but not exc. 5 km and depositing where directed |
| 6 | Cutting into existing manholes for connecting 150/200mm bore of pipe to new drainsmaking good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section, in cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate, smooth finished and reforming benching as required complete all as specified and directed. |
| 7 | M&L cement concrete type D-2 1:4:8(using 40mm graded stone aggregate) in bed of drain pipe 150mm bore pipe including forming cradles complete all as specified and directed.Note : Thickness of bed below the barrel of pipes 100 mm for pipes150mm dia andwidth D+300mm. |
| 8 | M&L cement concrete type D-2 1:4:8(using 40mm graded stone aggregate) in bed of drain pipe 200mm bore pipe including forming cradles complete all as specified and directed.Note : Thickness of bed below the barrel of pipes 150 mm for pipes200mm dia andwidth D+300mm. |
| 9 | M&L for 150mm nominal size (DWCPE) Double wall corrugated polyethylene pipe (SN8) including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring, rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and directed. |
| 10 | M&L for 200mm nominal size (DWCPE) Double wall corrugated polyethylene pipe (SN8) including all fixing accessories or fittings like socket/spigot joint with elastomeric sealing ring, rubber ring, SILAID rubber lubricants required for laying of pipes, laid in trenches, complete all as specified and directed. |
| 11 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. |
| 12 | M&L for brick workwith sub class \"B\" straight or curved on plan exc 6m mean radius and built in CM 1:6 complete all as specified and directed. |
| 13 | Description all as per srl item No 12.00 above but except brick. |
| 14 | M&L Brick work with sub class \"B\" brick staight or curved on plan to any radious in half brick thick wall built in CM 1:4 etc complete all as specificed and directed. |
| 15 | Demolition of reinforced cement concreteas manhole cover and similar worknot exc 15cm thick and removal of rubbish beyond MOD land complete all as specified and directed. |
| 16 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including rubbish off the premises complete all as specified and directed. |
| 17 | M&L PCC(1:3:6) type C-2(using 40mm graded stone agg.) as in foundation of manholes complete all as specified. |
| 18 | M&L for cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in surface channel as in benching/drains incl necessary form work etc complete all as specified |
| 19 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etccomplete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing and including necessary form workrequired complete all as specified and directed. |
| 21 | M&L providing RCC cement concrete(1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole covers slaband set in cement mortar 1:6complete all as specified and directed. |
| 22 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 23 | S&F SFRC manhole covers and frame medium duty of overall size 900mmX450mmX80mm thick factory made and test load 10 tonnes (MD-10), strength including necessary reinforcement as per IS : 1726-1991 complete in all respect as specified and directed. |
| 24 | S&F pre-cast factory made RCC GT Cover of Size 400mm x 500mmx 50mm thick or as per site requirement with 01 No handle and 150mm dia notch at one side of cover at center at 500mm long side complete all as specfied and directed. |
| 25 | M&L for Hard core, broken to gauge not exc 63mm, broken stone boulders, complete all as specfied and directed. |
| 26 | M&L for Cement concrete1:5:10 (using 40 mm graded granite stone aggregate) in sub base offlooring/ hard standing with interlocking paver blocks, complete all as specfied and directed.complete all as specfied and directed. |
| 27 | M&L for Sand filling under floors or in foundations including watering and consolidation, complete all as specfied and directed. |
| 28 | M&L for Machine pressed precast conctete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade, complete all as specfied and directed. |
| 29 | M&L cement concrete 1:3:6type C2, 75 mm thick as in plinth protection, surface to be finished even and smooth without using extra cement laid in alternate bays each bay not exc 3.0m in length with jointfilled with bituminous mastic complete all as specified and directed. |
| 30 | M&L 15mm thick rendering on fair faces of brick work surface in cement mortar (1:4) with using Water Proofing Liquid’.(Note: Water Proofing Liquid will be measure and paid seperately) complete all as specified and directed. |
| 31 | Supply onlywater proofingin Liquid, complete all as specified and directed. |
| 32 | M&L for Road cutting (i.e. premix, BM, WBM and hardcore) including making good with existing surface and including road cutting excavating in trenches (Soft/disintegrated) complete all as specfied and directed. |
| 33 | M&L salt glazed stone ware gully trap, square or round mouthed, 150 x 150 mm size, shape as required, including dismantling and taking out of old GT and jointing with old connection and pipes complete all as specified and directed. |