| 1 | To attend and rectify sewage complaint such as blockage of chocked bathroom / WC / kitchen block / WHBdrainage / chamber and also tightening of loose rain water pipe and outlet PVC pipe and making functional open drainage main hole sewage line etc complete all as specified and directed and directed any type any time between 9AM to 6PM including holidaycomplete all as specified and directed.Note : (1) Only experienced04 Nos sewage cleaners should be used to attend day to day complaints for above mentioned complaint shall be issued under respective item. (2) Contractor or his representative collect the complaints at 0900hrs from complaint cell of AGE B/R-I and the complaints will be attended / make good/rectified within 24hrs on receipt of the complaints and info the status of the complaint at 1700hrs every day to complaint cell. On failure of the same a penalty of Rs 250/- per day per complaints will be charged. |
| 2 | Cleaning of underground Horizontal sewage pipe of any dia upto 200mm (Cleaning length n.exc 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth and removing waste material/sludge to a distance of n.exc 300m and burrying in a pit and replacing manhole cover in position after cleaning complete all as specified and directed. |
| 3 | Dewateringmanhole of any depth in any position by pumping out and removing outside Military/Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after absorption of water and including providing and spreading required quantity of bleaching powder around the pit or dispose of waste material as per state protocol and washing the top of manhole with fresh water and sprinkling lime to make hygeinic complete all as specified and directed. |
| 4 | De-sludging of septic tank of any capacity including connected intercepting chamber, manhole shaft, sludge chamber & filterbeds of any description and in anmy position by pumping out and removing of sludgeoutside Military/ Defence land by mechanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spearding required qty of bleaching powder or dispose of waste material complete as per state protocol,including taking down of slab cover and placing the same in existing postion complete all as specified and directed. |
| 5 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in any type of soil complete all as specified and directed. |
| 6 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in soil complete all as specified and directed |
| 7 | Removal of excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed |
| 8 | Demolition and breaking up 150 mm dia bore drain pipe (salt glazed stoneware, AC or reinforced concrete) set in cement concrete complete all specified and directed. |
| 9 | M&L 150 mm bore Salt-glazed stone ware drain pipes crushing strength of less than 16KN/m laid in trenches and jointed complete all as specified and directed. |
| 10 | M&L 200 mm bore Salt-glazed stone ware drain pipes crushing strength of less than 16KN/m laid in trenches and jointed complete all as specified and directed. |
| 11 | M&L Ultra PE, DWC (Double wall corrugated)pipe confirming IS-16098 Part-2 2013 pertaining structure wall plastics pinning system for sewage 150mm and above bore pipe SN8 and all necessary fittings and fixtures complete all as specified and directed. |
| 12 | M&L for Ultra PE, DWC (Double wall corrugated)pipe confirming IS-16098 Part-2 2013 pertaining structure wall plastics pinning system for sewage 200 mm and above bore pipe SN8 and all necessary fittings and fixtures complete all as specified and directed. |
| 13 | Demolition and breaking up PCC packing & haunching against the sides of pipe for 150/200 mm dia bore drain pipe of any description complete all specified and directed. |
| 14 | M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 150mm bore pipes complete all as specified and directed |
| 15 | M&L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 for 200 mm bore pipes complete all as specified and directed |
| 16 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and forming benching as required. Internal dia of pipe 150mm complete all as specified and directed |
| 17 | Demolition of Brickwork or stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed . |
| 18 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 complete all as specified and directed |
| 19 | M&L for brick work with sub class \"B\" bricks straight or curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 but except bricks complete all as specified and directed . |
| 20 | M&L for Providing cement concrete type B-2, 1:2:4 (using 40mm graded aggregate) as in surface channel and drainscomplete all as specified & directed. |
| 21 | Taking down cement plaster any description on brick or stone wall/ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-Charge. |
| 22 | M&L for Rendering 15mm thick on brick surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing intergral water proofing compound in the proportion as mentioned in manufacturer\"s instructions complete all as specified and directed. |
| 23 | M& L for preparing plastered un plasteredold surfaces on wallone. coat of white wash complete all as specified & directed. |
| 24 | Supply only integral water proofing compound of approved manufacturer complete all as specified and directed |
| 25 | M&L for Providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings,platform,kerbs,manholes etc including weathering, slightly rounded or chamfered angles and throating as directed |
| 26 | M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed |
| 27 | Demolition of reinforced cement concrete complete all as specified and directed |
| 28 | M&L Reinforced cement concrete type B-1, 1:2:4 using 20mm graded stone aggregate in cover slabs of manhole/tanks complete all as specified and directed |
| 29 | M&L TMT steel bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed |
| 30 | M&L Form work to soffits of suspended slabs, floor slab etc n. exc. 200mm thickness flat for rough finished surface of concrete complete all as specified and directed |
| 31 | M & L for construction of soakage wells of 2.4 m dia and 3.0 m effective depth including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM (1:4), RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and directed. |
| 32 | M&L for construction of RCC Septic tank designed to carry sewage and sullage water, excavationin any type ofsoil, PCC 1:4:8 below foundation, Brickwork in CM (1:4) in walls , Base Slab , Baffle walls andRoof Slabincluding Vent shaft , manhole openings with cover connectionetc.,complete of size 4.6 m long by 2.3 m wide with effective depth of 1.5 meter and overall depth of 3 meter for 50 users complete all as specified and directed. |
| 33 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above gound level) complete all as specified and directed |
| 34 | M&L Hardcore of guage not exc 63mm , deposited, spread and levelled in layers n exc.15cmthick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 35 | M&L 75 mmthick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 36 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement to match the surace of tiles in foor/steps, over 15 mm thick screed bed or bedding layer in CM 1:6 complete as all specified and directed. |
| 37 | S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed |
| 38 | S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed |
| 39 | S & F stack clamp out of 50mm by 5mmflat iron & 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 75 mm nominal bore pipe complete all as specified and directed. |
| 40 | S & F stack clamp out of 50mm by 5mm flat iron & 16mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 110mm nominal bore pipe complete all as specified and directed. |
| 41 | S & F 75mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 42 | S & F 110mm bore PVC (SWR) bends of any radius, complete all as specified and directed. |
| 43 | S & F PVC 110mm bore (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 44 | S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap set complete all as specified and directed. |
| 45 | S&F, in repair, vitreous china wash down water closet pan (Pedestal pattern), white with \"p\" or \"s\" trap (excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed.Note for all above items:- (A) All types of equipments and safety kit required for working in foul condition shall be provided by the contractor to his workmen.The Engineer-in-Charge shall verify these aspects during currency of work.All precautions/safety measures shall be kept in mind during execution of work. |