| 1 | Taking down exsiting pole ofpost top lantern and depositing at MES storeyard in safe condition complete all as specified and all as directed |
| 2 | Taking down exsiting Bollard Garen lightcomplete and depositing to MES storeyard insafe condition complete all as specified and all as directed |
| 3 | Taking down existing post top hanging Led light fitting and bolard light fitting complete all as specified and directed . |
| 4 | Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area upto 16 Sqmm all as specified and directed. |
| 5 | Supply and instalation of 6 mtr post top lantern Pole MS with pure polyester powder coated Baseplate 200 x 200 x 12 mm thick Bottom pipe114 od x 3 mm thick x 1mtr lg, inbuilt junction box , Single Arm Bracket GI M16 x 600 foundation bolt and nut Assembly with 100W, 12000 lum , CCT 3000K Optic Type IV,PC polycarbonate Diffuser ,colour graphite gray or mate finishing complete all as specified and directed Make :- Philips Cat part NoSMI -25 MS or equivalant of Crompton / Luker |
| 6 | Supply and instalation of 2 mtr BollardMS with pure polyester powder coated base plate 245 x 245 x 10 mm thick, height 2000 mm inbuilt junction box , single post with 15 W Lum Base E 27 CCT 3000K , Type IV ,PC polycarbonate Diffuser ,colour graphite gray or mate finishingcomplete all as specified and directed . Make Philips Cat Part No ARTU / NOEMI MS or equivalant ofCrompton / Luker |
| 7 | Supplying,Laying, testing and Commissioning of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area of size 4 core 16 Sq mm complete all as specified and directed. |
| 8 | (a ) All as per Item Sl No 07 here in above but ofsize 4 core 10 Sq mm. |
| 9 | ( b ) All as per Item Sl No 07 here in above but ofsize 2 core 16 Sqmm . |
| 10 | Supply and fix in replacement of Street light control panel factory fabricated (CPRI type-tested) withMCB TPN 63 A - 1 No, Contactor TP 65 A- 1No, Astronomical Timer Street Light Control Panel with accessories outdoor type including connected switch gears, cables, etc and suitable sheet metal enclosure test and commisioning of Panel of 440V, out door cubical type with suitable provision of 25 x 3 mm angular base and vertical frame along with necessary PCC foundation and locking arrangement complete including taking out old unserviceable panel all as specified and directed. Note:- The quoted rate shall be inclusive of the following:-(i) Suitable copper control wiring inside Panel board, cable glands, cable lugs, supporting, insulaters etc.,(ii) Quoted rate is inclusive of angular base frame and PCC foundation Earth work and connected accessories.(iii) The Panel should be mounted min 0.30m above the ground level (iv) Design / drawing / BOM of the panel showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. (v) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. |
| 11 | S&F loop in- loop out fuse junction box ofinternal dimension 240x130x95mm made out of FRP sheet with weather proof conopy and locking screw fitted with and incl 6 Amps MCB - 1 No, 50 Amps rated 4 Way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on Garden light / pole of post top lantern /steel tubular including necessary aluminium clamps, suitable glands, lugs and GI nut andbolts including taking down old u/s junction box complete all as specified and directed .Make Sintexcode No GSJB 2817 or or equivalant of Havells |
| 12 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for errection of poles, laying of cables etc and getting out in hard/dense soil complete all as specified and directed. |
| 13 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm in depth hard dense soil complete all as specified and directed. |
| 14 | Removing excavated material (soil) to a distance not exc 50 m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. |
| 15 | M&L for providing sand cushioning for protection of UG cable in trenches with coarse RiddledEarthof approved qualityas approved in writing by GE including filling, spreading and punning down to desired thickness complete and all as specified and directed. |
| 16 | Supply and laying sub class \"B\" bricks laid across the cable for cable protection, above sand cushion complete all as specified and directed. |
| 17 | M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B2 (using 40mm grade stone aggregate) upto 20 cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note : GI pipes shall be measured and paid separately. |
| 18 | Supply and lay Galvanized Iron pipe Light Grade of dia 40mm for cable protection in trunches/ducts/floors or fixed on walls / roof / polesetc including suitable fixing accessories complete all as specified and directed . Note:-Wherever the protection pipes are to be laid/fixed on poles/walls/other surface the cost of clamping using appropriate size/type of MS clamps,nuts both etc is deemed to be included in the unit quoted rates. |
| 19 | M & L for cement concrete in foundations, filling and mass concrete type B-2, 1:2:4 (using 40 mm graded stone aggregate) complete all as specified and directed. |
| 20 | M & L for providing PCC (1:4: 8) type D-2,(40 mm graded aggregate)Cement concrete in foundations filling and mass concrete including necessary form work etc complete all as specified and directed.(For PCCBed of Poles) |
| 21 | M & L for providing PCC (1:3: 6) type C-2,(40 mm graded aggregate)Cement concrete in foundations filling and mass concrete including necessary form work etc complete all as specified and directed. |