| 1 | Taking down carefully existingunserviceable copper/aluminiumpoint wiring (light, fan, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbedsurface of wall, floors, etc complete all asdirected by Eng-in-Charge. |
| 2 | Taking down main switch, DB/change over/VTPN, MCCB, AC box of any capacity. |
| 3 | M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVCConduit and all accessoriesConcealedinwalls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with modular white cover plate with frame for housing the switches, socket outlets, fan regulators and blank cover etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following:- |
| 4 | One light point controlled by one switch. |
| 5 | One ceiling fan point controlled by one switch and fan regulator. |
| 6 | One exhaust fan point controlled by one switch. |
| 7 | One bell point controlled by one bell push |
| 8 | One 3 pin socket outlet 5 Amps independent board. |
| 9 | One 3 pin socket outlet 5 Amps on the same board with other switch. |
| 10 | One light point controlled by two Nos two way switches |
| 11 | All as per item No.3 here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor as main inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor as earth continuty conductor for one independent 6 pin 16 Amp socket. |
| 12 | S&F Modular switch, one way, 6 Amp 230, 1 module all as specified and directed by Engr in charge. |
| 13 | S&F Modular switch, two way, 6 Amp 230, 1 module.all as specified and directed by Engr in charge. |
| 14 | S&F switch Modular, single pole, one way,16 Amp ,1 module 230 Volt |
| 15 | S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt . |
| 16 | S&F socket Modular 6 Amp-2/3 pin combined 2 module |
| 17 | S & F ceiling rose surface polycarbonate body three terminal with ISI marked. |
| 18 | S&F Modularlamp holder Polycarbonate type with back plate suitable for Batten fittingSuitable for B22 type bulb with ISI marked. |
| 19 | S&F modular fan step regulator 120W2 module. |
| 20 | S&F modular bell push 6A ,1 module |
| 21 | S&F call bellding dong230 Volt , single phase. |
| 22 | S & F of BLDC White colour ceiling fan complete with blades and antisuside rod from existing roof / trus to fall ceiling,and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE,Winding material 100 % copper ,350RPM air velocity 215m3/min,anti rust bladesfive star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed.Note :1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 23 | M&L electric water heater (Geyser)25 Ltrs capacityAC 230V, 5 star rating Branded heavy duty automatic cutoff and including electric connection lead and water connection of both power consumption 2000 watt of suitable size and length and all accessories, grouting of nut bolt/fastner on wall and making good disturbed surface including disconnecting & taking down old existing geyser complete all as specified and directed. Note : 1) Old water heater(Gyser) shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 24 | Supply and fixing in replacement LED lights fittingmade of Aluminium extrusion 1x 20W (4 feet) , input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 , connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed byEngr -in -charge. Note :Warrenty on light should be of minimum 02 Years provided by contractor. |
| 25 | Supply and fixing in replacement LED light fitting made of Aluminium extrusion mirror type with high out put diffuser 1x10 watt 2 feet, input voltage 140-270 V AC,CCT 6500K, Lumin efficency 100 lm/watt ,surge protection upto 4KV , Voltage protection upto 440 V AC.PF >0.9 with driver including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed by Engr in charge.Note : Warrenty on light should be of minimum 02 Years provided by contractor. |
| 26 | S&F in replacement LED bulb B22 9 watt inverter bulb ,lumen efficency >900 lumin/watt in normal mode and 350 lumin/watt in power backup mode,CRI ≥80,CCT-6500K ,surge protection upto 4KV,Voltage Protection upto 400 volt,PF ≥ 0.9 suitable forbatten holder fitting complete all as specified and directed by Engr in charge.Note : Warrenty on light should be of minimum 02 Years by contractor. |
| 27 | Taking down and refixing connecting same electric meter SPup to 60 amp incl S & F suitable new board close recessed type of suitable size and making good to disturbed surface and matching with the existing colour of wall. all as specified and directed by engr in charge. |
| 28 | Taking down and Supply and fix new exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, 50Hz, RPM 1200, copper winding of sweep 300mm including cutting of suitable size holes on existing wall and making good disturbed work to match the existing surfaces and exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directedNote :1) Old Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 29 | Taking down and supply and fix new exhaust fan, plastic body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers, 50Hz, RPM 1200, copper winding of sweep 250mm including cutting of suitable size holes on existing wall and making good disturbed work to match the existing surfaces and exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directedNote :1) Old exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.2). 02 years guarantee to be provided by the contractor. |
| 30 | S & F in replacement Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.Note : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 31 | S & F in replacement Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall/ceiling including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor.Note : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length. |
| 32 | Supplied & fixedMCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V completeall as directed by Engr-incharge. |
| 33 | S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 ampsrated bus bar fixed on wall complete with all acessories complete all as specified and directed |
| 34 | S & F MCB single pole,having rupturing 10KA,6 amps to 32 amps as ordered 240 Volts \"C\" series |
| 35 | S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered \"C\" series. |
| 36 | S & F MCB Triple pole and neutral (TPN), having rupturing 10KA, 240/415 V 63 amps as ordered \"C\" series. |
| 37 | S & F in replacement of LED street light fitting 35 Watt 230 V ACCCT 5700K Lumens ≥100 lm/wattoutdoor type with high pressure die cast Aluminium housing high power led as lighting source and lens embedded pc cover having top opening seperate driver compantment and impact resistance of IK 07 WITH 10KV,OEM driver,PF 0.9, built in surge protection deviceheat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection .including bracket made out of GI pipe light grade 32mm bore not less than 1.20m long bent to shape required fixed to pole with suitable size 2 Nos clamps made out of 25X3mm flat iron with nut, bolts and washers completecomplete all as specified and directed.Note :- 02 Year warranty on light minimum should be provided by contractor. |
| 38 | Taking down existing earthing and M & L Earthing complete with galvanised steel earth plate electrode, 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level,connected to galvanised earth lead wire 4.0mm dia by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completionNote :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the costof the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs. |