| 1 | Excavating in post holes (or similar holes) each n.exc 0.5Cum, getting out, in any type of soil and getting out complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation etc or for shafts, man holes etc not exceeding 10 sqm on plan and getting out in hard/densesoil complete all as specified and as directed |
| 3 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed, at a level n.exc 1.5m above the starting point, complete all as specified. |
| 4 | Returning filling in including spreading leveling watering & well ramming in layers n.exc 25cm thick all as specified. |
| 5 | M&L Plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundationfillingetc complete all as specified. |
| 6 | M&L Plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundationfillingetc complete all as specified. |
| 7 | S&F GI tubing (ISI) marked) medium grade of various diameters as required in polyhouse construction with all fitting including fixing, erection complete to wall, ceiling or in polyhouse work complete all as specified and directed |
| 8 | S&F of GI fixtures and accessories like all types of clamps, L & T- fixtures, and the like for fixing of GI pipe in polyhouse work complete all as specified and directed |
| 9 | S&FMild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square exc 5cm but n.exc 10cm long,diameter of neck11 to 15 mm complete all as specified and directed. |
| 10 | S&F for Plain, galvanised, mild steel sheeting of 1.00mm thickness, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 or fixed with screws complete to the polyhouse complete all as specified and directed |
| 11 | S&F Multi-layered Polythene for covering of polyhouse fixed with zigzag spring insert, GI spring over 2 inch strip of new poly film over the main plastic in profile. (25% over lapping) complete all as specified and directed with following properties:- Fixed properties - 200 micron thick PE film having like UV stabilized( 3 years ) Thermic, diffused(>60%), Anti dust, Anti drip, IR Reflective cooling having minimum 80% level of light transmittance.Optional property - Anti sulphur( minimum sulphur 2200 ppm ,chlorine ,iron 100 ppm )for thecrops where sulphur consumption is high. For ex - rose cultivation (As per farmer choice) |
| 12 | S&F for shade net & insect net of 40 Mesh Insect Net Manufactured from 100% virgin HDPE mono Filament with 115- 120 GSM, 0.24 yarn diameter, 40x24 Knitting grid with 3 year life Under curtain. Variance (+-) range of 3 to 5% in above mentioned specifications as per IS16513:2016 including fixing with nylon rope, & hooks of appropriate dia as specified by manufacture complete all as specified and directed |
| 13 | S&F for 32mm dia black HDPE pipe/ conduit for fogging system in polyhouse including fixing with joints and inlet pipe from pressure motor complete all as specified and directed |
| 14 | S&F for micro hanging fogger sprinklers 40 to 100 LPH with adjustable knob fixed to HDPE pipe for fogging system in polyhouse complete all as specified and directed |
| 15 | S&F for 1HP pressure motor for fixing in fogging system, fixing complete with 3mtr suction pipe of heavy duty complete all as specified and directed |
| 16 | S & F 1000 litres capacity Three Layers White colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimumweight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed |
| 17 | M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) all as specified & directed by Engineer-in-charge. |
| 18 | Extra over stone walling for hammer dressing to face stones with maximum depression on face from straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type brought upto courses. |
| 19 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with UltraTech READIPLAST by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height all as specified and directed) |
| 20 | M&L for preparation of newly plastered surfaces and applying Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and as directed by Engr-in-Charge. |
| 21 | M&L for providing cement concrete type B-1 1:2:4 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 22 | S&F in repair 6mm thick coloured polyicarbonate sheet (ISI marked) with shelf drilling steel screw with washer on roof and joint of two sheet will be filled with silicon weather proof sealent and cover with aluminum strip of size of 50x3 mm top and bottom and fixed with shelf drilling steel screw with washer on roof complete all as specified and directed. |
| 23 | S &F Rolled sections Fe-410- W(Gde- E-250) quality- Bas in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete. |
| 24 | M&L for preparation of new surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete. |
| 25 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring / hardstanding complete all as directed. |
| 26 | M&L for broken jaisalmer stone pitching in wall, dado, skirting and the like, and in floors, steps, platforms etc. incl bedding 15mm thick in CM 1:4, closely packed together and filling of gaps with CM 1:4 complete all as specified and directed by Engineer-in-charge. |
| 27 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete including packing all around with PCC 1:2:4 complete all as specified and directed. |