| Sl. No. | Item Description |
| 1 | S&F second class hardwood plain,solid ,straight,chowkats and frames,wrought, framed rebated on the solid ,rounded or chamfered,put together with glue pinned at joints, complete in all respect as specified and directed. |
| 2 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor including taking down existing sheet complete all as specified and directed. |
| 3 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor for height of building exceeding 10 metres but not exceeding 20 metres including dismatalling of existing sheets including taking down existing sheet complete all as specified and directed. |
| 4 | S&F of powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in ewach door, hinges, anodised aluminium snap beading screws etc. complete all as specified and directed. |
| 5 | M&L for 18-20 mm thick machine cut kota stone slab flooring of size not less than 500 x 500 mm over 15 mm thick cement mortar (CM) 1:6 screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed. |
| 6 | M&L for 18-20 mm thick machine cut kota stone slab of size not less than 500 x 500 mm in riser of steps, skirting, dado and pillar over 15 mm thick rendering in cement mortar (CM) 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete in all respect as specified and directed. |
| 7 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed |
| 8 | Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed |
| 9 | M&L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks including dismantling of existing surface complete all as specified and directed. |
| 10 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 11 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, including dismantling of existing surface complete all as specified and directed. |
| 12 | S&F in repair for Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using Fe-410W (Grade E-250 quality \"A\") including necessary welding complete complete allas specified and directed. |
| 13 | M& L for rendering/plastering 15 mm thick in cement mortar 1:4 on faces of brick or concretesurfaces and finished the surface even and smooth without using extra cement including taking down existing surface complete all as specified and directed. |
| 14 | M&L 15 mm thick plastering on brick/ stone/ concrete surfaces of of wall in cement mortar (1:6), finished even and smooth without using extra cement, including taking down existing surface complete all as specified and directed. |
| 15 | Supply only integral water proofing compound complete all as specified and as directed. |
| 16 | M&L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including formwork including dismantling of existing surface complete all as specified and directed. |
| 17 | S&F in repair for 20 mm dia harrison rails, anodised aluminium alloy with fixing brackets, stops, rollers etc. complete all as specified and as directed. |
| 18 | Supply and Fix exposed GI powder coated snap grid frame work for false ceiling in flat or in sloping , of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with 4mm dia GI wire as suspender and including 4mm thick decorative pre -painted non asbestos board (E-Board) in false ceiling including fixing arrangement from steel/wooden truss of any type including dismantling of existing surface complete all as specified and directed. |
| 19 | Providing and laying plinth protection of 75mm thick cement concrete (1:3:6) type C-1, (using 20mm nominal size crushed and graded stone aggregate), laid in alternate penals/bays and finished the surafce even and smooth without using extra cementincluding dismantling of existing surface complete all as specified and directed. |
| 20 | S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. or for window grill of appd size and shape including fixing with aluminium \"U\" shape section for fixing etc. complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) |
| 21 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge. |
| 22 | S&F powder coated aluminium sliding window with/without sash bars, aluminium sections of thickness 2mmincluding necessary joining cleats, glazing clips, EPDM rubber packing (of 50 No grade), powder coated aluminium snap beading, screws, center grooved stainless steel ball-bearing double roller2 position height adjustment, sound/dust brush, recessed handle with locking arrangement complete in all respect as specified and directed. (Powder coating shall be min 50micron) (Note:all external members to be joined at 45 degree angle at corner) complete in all respect as specified and directed. |
| 23 | S&F in repair for aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 24 | S&F in repair for cast aluminium alloy handle, cast type, 125 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 25 | S&F in repair for aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. |
| 26 | S&F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed. |
| 27 | M&L second class hardwood 30 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | S&F in repair for 100mm size mild steel butt hinges complete allas specified and directed. |
| 29 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 including dismantling of existing surface complete all as specified and directed. |
| 30 | M&L in repair for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete in all respect as specifified and directed. |
| 31 | Material and labour for complete removal of existing treatment on wall and applying two coats of oil bound distemper and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2mm thick (in two layers), wall care putty complete in all respect as specified and directed. |
| 32 | M&L for preparation of old decorated plastered surface of wall after complete removal of existing treatment and applying two coats of weather coat over 2 mm thick wall care putty (in two layers) over a coat of primer including preparation of surface, complete in all respect as specified and directed. |
| 33 | M&L for preparation of old decorated wooden surfaceswith pre mixed wood filler used as putty of grith exc 10cmand applying two coats of synthetic enamel paint complete all as specified and directed. |
| 34 | M&L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 35 | M&L for preparation of old undecorated steel surfaces with pre mixed steel filler used as putty and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 36 | Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge |
| 37 | Supply & fix sheet in repair for glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 38 | S&F in repair for framed work such as grills, gratings,etc with ends of bars shouldered and /or riveted, or forged into spikes framed guard bars barred iron doors , laddersand similar work conforming to Fe 410-0 or FE310-0 complete all as specified and directed. |
| 39 | S&F in repair for stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 40 | M&L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 41 | M&L for 2nd class hard wood plain fillets ,square, rectangular or triangular in section ,clean sawn ,secured with nails or brads (sectional area exc 6 sq.cm & n exc 13 sq.cm)as in studs of ceiling / sunshed./truss members complete all as specified and directed. |
| 42 | M&L for solid PVC wall lining consisting of 5 mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed. |
| 43 | M&L for 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed. |
| 44 | M&L for preparation of newly plastered surface of wall and applying two coats of weather coat over 2 mm thick wall care putty over a coat of primer including necessary preparation of surface, complete in all respect as specified and directed.L |
| 45 | M&L for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 2 mm thick (in two layers), wall care putty, complete in all respect as specified and directed. |
| 46 | M&L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor including taking down existing sheet complete all as specified and directed. |
| 47 | S&F in repair for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality \"A\") complete all as specified and directed. |
| 48 | S&F powder coated aluminium ventilator with half portion louvered (adjustable)with 4mm thick glass in louver and balanced portion fixed 4mm thick frosted glass glazing including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete in all respect as specified and directed. |
| 49 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 50 | S&F factory made solid PVC moulded door shutter, 28 to 30 mm thick (stiles) with particle board core, with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. |
| 51 | Providing & laying heavy duty non skid coloured digital printed floor tiles of size 300mmX300mm ,8 to 10mm thick set and jointed in neat cement slurry and pointed with white cement with pigment to match the tiles colour over and including 15mm thick screed bedding in cm 1:6 and dismentling of existing tiles/blocks of any discription complete in all respect as specified and directed. |
| 52 | Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete in all respect as specified and directed. |
| 53 | M&L for complete removal of existing treatment on wall and applying two coats of oil bound distemper (OBD) and finished another one coat with spunge roller over one coat of alkali resistant priming paint over 3 mm thick (in two layers) wall care putty, complete in all respect as specified and directed. |
| 54 | M&L for preparing of old decorated wooden surface, of any description, not otherwise described, over 10 cm width or girth, and applying two coats of synthetic enamel paint, complete in all respect as specified and directed. |
| 55 | M&L for preparation of old decorated steel surface of any description not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint, complete in all respect as specified and directed. |
| 56 | S&F PVC coloured insulated over MS pipe 20 mm dia curtain rod with fixing bracket, stops, rollers etc. complete all as specified and directed. |
| 57 | M&L for half brick work with subclass ‘B’ old size bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:4) including dismantalling of brick work built in cement mortar in any position, complete in all respect as specified and directed. |
| 58 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 59 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 60 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 61 | M&L for chain link fencing MS galvanized fencing any size or type fixed to RCC post including securingor tying with GI MS wire stape etc complete all as specified and directed by engr-in-charge. |
| 62 | Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed. |
| 63 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and getting out in soft/ loose soil complete all as specified and as directed. |
| 64 | M&L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 65 | M&L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 66 | M&L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 67 | M&L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. |
| 68 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 69 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 70 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed. |
| 71 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces of concrete complete all as specified and as directed. |
| 72 | M&L for mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 73 | Spreading and levelling to under flooring, in layers n. exc. 25 cm thick andwell ramming including watering as required of excavated loose soil, as retreived against respective excavation item complete in all respect as specifified and directed. |
| 74 | M&L for 40 mm thick damp proof course in cement concrete M15(Nominal mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with integral water proofing compound to horizontal or vertical surfaces including necessary formworks complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 75 | M&L 75 mm thick PCC (1:3:6) type C-2 using 40 mm nominal size crushed and graded stone aggregate laid in floor, path etc. or of similar type finished the surface even and fair without using extra cement complete in all respect as specified and directed. |
| 76 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 77 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 78 | M&L for rendering/plastering 10mm thick in cement mortar 1:3 on faces of brick or concretesurfaces and finished the surface even and smooth without using extra with water proofing compound over chajja, coping etc complete in all respect as specifified and directed. (Water proofing compound shall be measured and paid under supply item only) |
| 79 | M&L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 80 | M&L for mild steel iron frame for door , windowusing joist, channel, angle, tee, tubes, flat sections, fixed independently, without connecting plates, etc. conforming to Fe. 290., Gde-E-165complete in all respect as specifified and directed.(MS hinge shall be paid under supply only item) |
| 81 | S&F aluminiu door floor spring,Suitable for left-right opening & single-door,double door two direction opening, 90° hold open, Suitable for the size of door 950 x 2100mm complete all as specified and directed. |
| 82 | S&F mortice lock, vertical type, mild steel, 2 levers, vertical type, 100 mm size including protective coating of painting fixed in position complete all as specified and directed. |
| 83 | S&F steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and as directed. |
| 84 | M&L for preparation of new plastered surface of walland applyingtwocoats of weather coat over two coat of home shield over 3mm thick (in two layers), wall care putty over a coat of primer complete in all respect as specifified and directed. |
| 85 | M&L for preparation of newly undecorated plastered surface of wall and applying two coats of oil bound distemper (OBD) and finished with spunge roller over a coat of alkali resistant priming paint over 3mm thick (in two layers), wall care putty complete in all respect as specifified and directed. |
| 86 | Preparation of newly plastered surfaces on ceilings and applying two coats of white wash complete all as specified and as directed. |
| 87 | M&L for writing letters or figures (block roman, Italic or Indian) through synthetic enamel paintof 30cm high upto 12m height building over square or round base painting and necessary scafolding arrangement complete in all respect as specified and directed. |
| 88 | M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed (Area of the sub structure in contact with backfill to be measured). |
| 89 | M&L for treating the top surface of filled earth at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface complete all as specified and as directed. |
| 90 | M&L for shingle filling in floors or pavings, laid in layers not exceeding 15 cm thick, spread, levelled, and blinded with earth and rammed including watering complete all as specified and as directed. |
| 91 | M&L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and as directed. |
| 92 | M&L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 93 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed. |
| 94 | M&L for RCC M20 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed. |
| 95 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 96 | S&F mild steel sections (Beam, tee, angle, channel or flat sections) in rooftrusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing, independent fixing with welding etc.including distance pieces, cleats etc. using Fe 410-W (Gde E-250) quality Acomplete in all respect as specifified and directed. |
| 97 | M&L for any colour of granite stone without white spots Granite stone slab 17 to 19 mm thick, as in floor, dado, steps, laid over and including screed bed 15 mm thick in cement mortar (CM) 1:6, jointed and pointed with white cement mixed with pigment to match the shade of stone including cuttingl rubbing and polishing surface, including cutting for wash hand basin, sink, gas pipe hole etc., to the entire satisfaction of the Engineer-in-Charge, complete in all respect as specified and directed. |
| 98 | S&F 20mm dia tubular towel rail 600mm long of cast copper alloy, chromium plated with end brackets complete in all respect as specified and directed. |
| 99 | S&F hand shower (health faucet) with 1.2 meter long PVC tube & wall hook as per Product Code: ALD-CHR-563 of Jaquar or equivalent of kohler/marc complete all as specified and as directed. |
| 100 | S & F 5.50 mm thick of 1.40 m x 1.0 m size bevelled edge mirror of selected quality decorative type designer mirror with chromium plated brass screws and cup washerscomplete all as specified and directed. |
| 101 | Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge. |
| 102 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails.M.S. frame shall be covered with heat moulded plain colour PVC \"C\" channel haivng a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for top rail & bottom rails; Panelling of plain colour PVC sheet to be fitted in the M.S. frame weloded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling and fixing in the frame at site as per specification & drawing, complete in all respcet as specified and directed. |
| 103 | S&F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 110 mm dia, fixed to walls complete all as specified and as directed. |
| 104 | S&F PVC (SWR), type A as per IS 13592: 2013 single socketed rain water pipes in any length with rubber ring joints, 75 mm dia, fixed to walls complete all as specified and as directed. |
| 105 | S&F PVC (SWR) bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 106 | S&FPVC (SWR) Tee(87.5⁰) single, 110 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and directed. |
| 107 | S&FPVC (SWR) vent cowl, 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed. |
| 108 | S&FPVC (SWR) bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 109 | S&FPVC (SWR) vent cowl, 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed. |
| 110 | S&FPVC (SWR) Tee(87.5⁰) single, 75 mm dia without inspection door conforming to IS 14735: 1999 complete all as specified and as directed. |
| 111 | S&F 20mm outer outer dia CPVC pipe SDR 11 including plain CPVC SDR 11 fitting such as bend, tee, elbow, union, reducer etc laid or fixing/ clamping on floor/ surface/ air/ wallcomplete all as specified and directed. |
| 112 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 113 | S&F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete complete all as specified and as directed. |
| 114 | S&F in repair table top wash hand basins (WHB), vitreous china of size 500x400 mm x 150 mm ,Waste coupling 32 mm SS and PVC waste pipe including 15 mm bore dia fancy type CP finish swan neck basin mixer, cast copper alloy with capstand heads, screw down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screw for iron pipes complete in all respect as specified and directed. Make:- Jaquar, Cat Part No. JDS-WHT-25909 (TT WHB), Cat Part No FLR-CHR-5167NB (Swan neck basin mixer) including 20mm granite table top size(1.0 mtr x 0.6 mtr) and cabinet front side views material made by pre laminated 18 mm thick HDHMR board for long life.2 drawers and 1 door space.hardware ss auto closed hinges joints door diamond shape drawers handle,ss drawers channels for smoothly open and close the drawers complete all as specified and directed. |
| 115 | S&Fin repair for vitreous china urinal, flat stall type of 37.5X39X59cm white (minimum) (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe. (Exclusive of fixing supply pipe to flushing cisternetc. complete in all respect as specified and directed. |
| 116 | S&F in repair for 8 mm thick curved shaped urinal partition with frosted glass size 900 x 450 mm including stainless steel fixing brackets complete in all respect as specified and directed. |
| 117 | S&F in repair for aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed. |
| 118 | S&F in repair for rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 119 | S&F in repair for ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed by the Engineer-in-Charge. |
| 120 | S&F in repair vitreous chinaware sqatting pan of size 580 x 440 mm, \"ORISSA PATTERN\" with new PVC \"P\" or \"S\" trap bedded in cement concrete (excluding flushing cistern and flush pipe) with integral foot rests, complete in all respect as specified and directed. |
| 121 | S&F in repair for vitreous china wash down water closet Pan (pedestal pattern) white including plastic water closet seat cover, white, closed pattern with flat bottom, and mild steel chromium plated hinging device (exclusive flushing cistern and flush pipe) complete all as specified and directed. |
| 122 | S&F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. |
| 123 | S&F in repair for 15mm size PVC connection pipe with PTMT nut of length 450mm complete all as specified and directed. |
| 124 | S&F in repair Health faucet cast coper alloy CP finish 15 mm dia fancy type with brass plated flexible hose and wall hook, 1.00 mtr complete, in all respect as specified and directed. |
| 125 | S&F in repairs 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. |
| 126 | S&F in repairs long body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete in all respect as specified and directed. |
| 127 | Providing & laying heavy duty non skid coloured digital printed floor tiles of size 300mmX300mm ,8 to 10mm thick set and jointed in neat cement slurry and pointed with white cement with pigment to match the tiles colour over and including 15mm thick screed bedding in cm 1:6 and dismentling of existing tiles/blocks of any discription complete in all respect as specified and directed. |
| 128 | S&F tower ring of copper alloy CP finishedcomplete all as specified and directed. |
| 129 | S&F toilet paper holder of vitreous china, box type, white fixed to walls with chromium plated brass screws complete all as specified and as directed. |
| 130 | S&F Liquid soap container of frosted glass fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete in all respect as specified and directed. |
| 131 | Supply and fixed unplasticised PVC (SWR) Gully trap125/110 mm, setting and jointing with solvent cement complete in all respect as specified and directed. |
| 132 | S&F brass sliding door bolts with sand-cast brass hasp, staple and fixing bolts or clips and rolled or drawn brass bolts (type-1) or Brass sliding door bits with diecast brass hasp, staple and fixing bolts or clips and rolled or drawn brass bolts (type -2), satin finish or polished, 300 mm long complete all as specified and as directed. |
| 133 | M&L for soakage wells 1.80m dia and 3.0m depth excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete in all respect as specified and directed. |
| 134 | M&L forRCC Septic tank designed to carry sewage and sullage water, excavationin any type ofsoil,PCC 1:4:8 below foundation, RCC Type A-1 1:1.5:3Mix Baffle walls andRoof Slabincluding beams etcwithVent shaft,manhole openings with cover connectionetcfor 05 users capacity all as per Drawing available with sub division complete all as specified and directed. |
| 135 | M & L in replacement of point wiring with 1.5 sqmmFRLSH, PVC insulated stranded copper conductor single core including non metalic PVC casing caping(MMS ISI) of size not less than 20 mm on wall/over ceiling,modular metal boxes of required size and with modular plates incl of all accessories and all as specified including 1.5 sqmm FRLSH PVC insulated sheathed multistranded copper earth conductor to common earth and connected to earth dollyfor light / fan/ bell point controlled by one switch.Note:- (i) Cost of PVC casing caping, modular plates,frames, cover plates etc; are deemed to be included in the quoted rate. |
| 136 | All as per item 135 here-in-before for 3 pin 5 amps switch socket combination on indpendent board with 1.5 sqmm capper cable complete all as specified and as directed. |
| 137 | All as per item No.135here-in- before but for 3 pin 16 Amps switch socket combination on independent board with 2.50 sq mm copper cable complete in all respect as specified and directed. |
| 138 | All as per item 7.0 above but for One 3 pin socket outlet 5 Amps on same board complete all as specified and as directed. |
| 139 | S&F in replacement of modular switch10A,1 module single pole, one waycomplete all as specified and directed. |
| 140 | S&F in replacement of modular socket outlet 5 pin ,10 Amps,2 module, 240 Volts complete all as specified and directed. |
| 141 | S&F in replacement of modular socket outlet 5 pin ,16 Amps,2 module, 240 Volts complete all as specified and directed. |
| 142 | S&F in replacement of modular switch16A, 1 module single pole, one waycomplete all as specified and directed. |
| 143 | S&F in replacement ofceiling rose polycarbonate typethree terminals complete all as specified and directed. |
| 144 | S&F in replacement of modular step type electronic fan regulator ,two module 120 watt single pole 240 Volts complete all as specified |
| 145 | S&F in replacementLED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 146 | M&L in replacement of LED wall decorative light fitting suitable for 20W lamp of make Philips Model No. 34303 Grace led wall light or equivalent make asas specified and directed. |
| 147 | S&F in replacement new generation energy saving and environmental friendly long life 35/40W LED wall street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top Opening seperate driver compartment with IP66 protection and impact resistance of IK07including necessary brackets (made out of suitable bore GI pipe light grade appx 0.6 meter long bend to shape) nuts, bolts, etc fixed on walls with MS clamp complete all as specified and directed. Make:- Philips of Model -SmartBright Street or equivalent in Wipro / Crompton. |
| 148 | Supply and fixing in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 149 | Supply, laying, jointing, testing and commissioning in replacement of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items). |
| 150 | M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed. (Punned thickness only shall be measured and paid) |
| 151 | M&L laying well burnt old size bricks, sub calss \"B\" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed. |
| 152 | M&L fortaking down and rewinding of Exhaustfan upto 380/480/450 mm sweep after dismantling and taking out the burnt winding coils and rewinding with super enamelled copper winding wire of suitable size and gauge including insulation, Varnishing, drying etc complete and refixing the same after rewinding and testing complete all as specified and directed. |
| 153 | Supply and draw in replacement of submain wiring with two single core 6 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in PVC casing capingincluding 6 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete incl taking out old unserviceable submain wiring of any type.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 154 | Supply and draw in replacement of submain wiring with two single core 4 sq mm FRLSH PVC insulated copper cable 1100 volts grade multi stranded, sheathed conductor in concealed PVC conduitincluding 4 sq mm multi-strand FRLSHPVC insulated copper wire for earth continuity conductor connected to common earth dolly complete and making good disturbed surface complete.Note:- Cost of PVC conduit, cutting chases on walls and making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with the existing shade / tint are deemed to be included in the rates quoted. |
| 155 | S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed. |
| 156 | M&L in replacement of sheet metal enclosure forTPN DB-VTPN 4 way 415 V, double door , 250 A copper bus bar , IP 43 , including 100 Amp MCCB as incomer as flush mounted complete all as specified and as directed. |
| 157 | S&F in replacement of sheet metal enclosure double doorfor MCB DBs SPN 8 way 240 V amps rated bus bar SPN, complete flush mounted all as specified and as directed. |
| 158 | M&L in replacement of MCB single pole 6 to 32 Amps,240 volts,10 KA, complete all as specified and directed. |
| 159 | S&F in replacement of single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 16 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 160 | M&L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge. |
| 161 | Supply, Laying, testing & commissioning in replacement of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 4 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends and necessary saddle clamp all as specified and directed by Engg-In-charge. |
| 162 | M&L in replacement of sheet metal enclosure MCB DBs SPN , 12 way 240 V, with 100 A rated bus bar , double door, IP 43 as per IEC 61439-3 , suitable for flush mounting and surface mounting complete all as specified and as directed. |
| 163 | S&F in replacement of Isolator/ MCB single pole (SP) 5 to 40 Amps,240 volts , C curve , AC , 50 Hz ,10 kA complete all as specified and directed. |
| 164 | S&F in replacement of double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 100 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 165 | S&F in replacement LED Tube light luminaires, 20-22 watts, lumen output not lessthan 2000 (4 feet), made of anodised extruded aluminium housng, with high transmissivity diffuser, high lumen output, with suitable integrated electronic driver, and operated in single phase, 230 volts, 50HZ, all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable offrom connector and ceiling rose, complete all as specified and directed. |
| 166 | S&F in replacement of LED bulk head wall light fixture 10 Watt , pressure die cast housing , IP 66 protection and IK 09 impact resistance suitable for surface and wall mountingcomplete all as specified and as directed. |
| 167 | Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete in all respect as specifified and directed. |
| 168 | Supply & fixingin replacement of exhaust fan fresh air 300 mm sweep AC 230 volts single phase with louvers including making connection with three core PVC insulated 1100 volts grade multi strandedcopper wire of appropriate size includingtesting complete all as specified. |
| 169 | Supply and fixing in replacement of ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed. |
| 170 | S&F in replacement of MCB Single pole & neutral (SPN)32-40 Amps, 240 volts , C Curve, AC , 10 kA complete all as specified and directed. |
| 171 | Supply, laying, jointing, testing and commissioning in replacement of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 172 | S&F in replacement of sheet metal enclosuredouble door for DBs SPN 4 way 240 V completedouble door, flush mounted all as specified and as directed |
| 173 | Supplying & laying in replacement of 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 174 | Supplying & laying in trenches in replacement of 25 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 175 | S&F in replacement of 25 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail