| 1 | 1. Supply of Voltmeter Model RISH EINE NX Input - 100- 500 V L-L -Programmable-, 3Ph 3W by 4W Network, Accuracy Class - 1.0, | As per Specification Sheet Attached |
| 2 | 2. Supply of current meter Model RISH EINE NX ,Input 1A by 5A -Programmable-, 3Ph 3W by 4W Network, Class - 1.0, | As per Specification Sheet Attached |
| 3 | 3. Supply of current meter - Model RISH VDC C with Shunt , Input - 0 - 75 mV, Display - 14 mm LED Display, Accuracy Class - 0.1, | As per Specification Sheet Attached |
| 4 | 4. Supply of Voltmeter Model RISH EINE plus , Input - 0-500 V, Accuracy Class - 0.5, , AUX 20-60VDC | As per Specification Sheet Attached |
| 5 | 5. Supply of Ammeter Model RISH EINE plus with shunt, Input - 0 - 75mV | As per Specification Sheet Attached |
| 6 | 6. Supply of powerful DC signal isolator model SI101,DC Isolator 1 Input,1 Output, Input - 0-75mV DC | As per Specification Sheet Attached |
| 7 | 7. Supply of ammeter Model RISH EINE NX Input-1 by 5A Programmable, 1 phase network Accuracy Class -1 4 Digit, | As per Specification Sheet Attached |
| 8 | 8. Supply of Voltmeter Model RISH EINE NX Input - 57.8 - 480V L-N Programmable, 1 Phase Network, Accuracy Class - 1.0, | As per Specification Sheet Attached |
| 9 | 9. Supply of Voltmeter Model RISH VDC C input - 0-75mV, Display - 14 mm LED Display , Accuracy Class - 0.1 , | As per Specification Sheet Attached |
| 10 | 1. Supply of voltage transducer Model TV 808, Type - DC Isolator 1 Input-1 Output - E8 Housing- Input 0-400 V DC Output - DC Voltage - 0-5V | As per Specification Sheet Attached |
| 11 | 11. Supply of Ammeter Model RISH EINE plus Input -0-75mV, Accuracy Class - 0.5 , AUx 40-300VAC by DC, Without Shunt | As per Specification Sheet Attached |
| 12 | 12. Supply of current transducer Model RISH CON I , Input - 1-5A | As per Specification Sheet Attached |
| 13 | 13. Supply of current transducer Model TV 808 ,Type - DC signal Isolator 1 Input-1 Output - E8 Housing- Input - 0-350 V dc, Output -DC Voltage - 0-5V | As per Specification Sheet Attached |
| 14 | 14. Supply of current transducer SI101, Type - DC signal Isolator 1 Input-1 Output Input - 0-75mV , Output -DC Voltage - 0-5V | As per Specification Sheet Attached |
| 15 | 15. Supply of voltmeter Model EQ 91, CL 1 , Analog Voltmeter Scale -0-500 V-, 90degree, 96mm x 96mm | As per Specification Sheet Attached |
| 16 | 16. Supply of voltmeter Model EQ 91, CL 1 , Analog Voltmeter Scale -0-300 V-, 90degree, 96mm x 96mm | As per Specification Sheet Attached |
| 17 | 17. Supply of ammeter Model EQ 91, CL 1.0 ,CT Operated, scale -0-200 A- CTR 200 by 5 amp | As per Specification Sheet Attached |
| 18 | 18. Supply of ammeter Model PQ 91 with shunt 150A by 75mV, CL 1.0 ,90 degree, scale -0-150 A | As per Specification Sheet Attached |
| 19 | 19. Supply of current meter Model VL 91 ,CL 1.0, 96X96 mm , scale 240 Degree -0-25 A-, CTR, 25 by 5 amp | As per Specification Sheet Attached |
| 20 | 20. Supply of Voltmeter Model VL 91 ,CL 1.0, 96X96 mm , scale 240 Degree -0-500VAC- | As per Specification Sheet Attached |
| 21 | 21. Supply of DC Voltmeter meter Model PL 91 ,CL 1.0, 96X96 mm , scale 240 Degree -0-100VDC- | As per Specification Sheet Attached |
| 22 | 22. Supply of current meter Model VL 91 | As per Specification Sheet Attached |
| 23 | 23. Supply of current meter Model VL 91 ,CL 1.0, 96X96 mm , scale 240 Degree -0-150 A-, CTR, 150 by 5 amp | As per Specification Sheet Attached |
| 24 | 24. Supply of DC Voltmeter meter Model PL 91 ,CL 1.0, 96X96 mm , scale 240 Degree -0-400VDC- | As per Specification Sheet Attached |
| 25 | 25. Supply of ammeter Model RISH EINE plus with shunt 1200A by 75mV, Input - 0 -75mV, | As per Specification Sheet Attached |
| 26 | 26. Supply of voltmeter Model PQ 91, input - 4-20mA, size 96mm X 96mm, class 1.5, 90 degree | As per Specification Sheet Attached |