| Sl. No. | Item Description |
| 1 | Supply, install, commissioning & testing of Submersible Pump, Noiseless type perfectly suitable for Desert Cooler Underwater Motor upto to 14W, Head - 1.4 Mtr, Flow - 1000 LPH, Water Outlet 16mm, operating on Single Phase, 230V, 50Hz, AC supply incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : WE Hydroponics, Model No : JQP-1000-14W or techno-commercially equivalent. |
| 2 | Supply, install, commissioning & testing of Desert Cooler Fan Motor, multi speed type, perfectly suitable for operating in Single Phase, 230V, 50Hz, AC Supply complete with blades & compatible for Desert Cooler of 4000 CFM and upto 90 Litre capacity incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Bajaj, Model : Bajaj PX 90 Litre DC or techno-commercially equivalent.IMPORTANT NOTES for ITEM Nos 1 & 2 :1) Unit rate quoted is deemed to be inclusive of replacement guarantee of 2 Yrs for the entire Defect Liability Period. 2) Cost of any brazing, welding etc. work is also deemed to be included in the unit quoted rates.3) Anything missed out in the item specifications but technically required for efficient operation of the item / system is deemed to be included in the unit quoted rates.4) Quoted rate is also deemed to be inclusive of any minor spares as decided by the Engr-In-Charge.5) Original Purchase Vouchers & Test Certificates for the item is to be submitted to the Engr-In-Charge for checking/records purpose. |
| 3 | S&F PVC distributor 3 way suitable for 16mm bore pipe connection of Desert Cooler of size & perfectly suitable for existing Make / Model / System incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 4 | S&F PVC Pipe flexible type 16mm dia for Water Coolers of different capacities & perfectly suitable for existing Make / Model / System incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 5 | S&F Wood Wool for pads of Desert Coolers of different capacities perfectly suitable for existing Make / Model / Size / System incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 6 | M&L for writing of SM/MES Numbers on Hylium / PVC sheet with printed / engraved / painted letters of size minimum 1 inch x 3 mm & fixing to the appliances / eqpts by adhesive etc. complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 7 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Deep Freezers of capacities more than 300 Ltrs to 420 Ltrs incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) |
| 8 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Deep Freezers of capacities more than 240 Ltrs to 300 Ltrs incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) |
| 9 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Deep Freezers of capacities more than 160 Ltrs to 240 Ltrs incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement)IMPORTANT NOTES for ITEM Nos 7 to 9 :1) Unit rate quoted is deemed to be inclusive of replacement guarantee of 2 Yrs for the entire Defect Liability Period. 2) Cost of any brazing, welding etc. work is also deemed to be included in the unit quoted rates.3) Anything missed out in the item specifications but technically required for efficient operation of the item / system is deemed to be included in the unit quoted rates.4) Quoted rate is also deemed to be inclusive of any minor spares as decided by the Engr-In-Charge.5) Original Purchase Vouchers & Test Certificates for the item is to be submitted to the Engr-In-Charge for checking/records purpose.6) Cost of filling of Refrigerant Gas (if any) shall be measured & paid separately under relevant items. |
| 10 | S&F OLP Relay Assy perfectly suitable for Refrigerators of capacities 165 to 360 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 11 | S&F Thermostatic Switch perfectly suitable for Refrigerators of capacities 165 to 360 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 12 | S&F Magnetic Door Gasket perfectly suitable for Refrigerators of capacities 165 to 360 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 13 | S&F Cabinet Lamp perfectly suitable for Refrigerators of capacities 165 to 360 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 14 | S&F Fan Motor of existing size / type / model etc. perfectly suitable for Refrigerators of capacities 165 to 360 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 15 | M&L for Servicing of Water Cooler of capacity 40/80 Ltr by proper cleaning with air pressure, tightening of Nuts / Bolts and wet cleaning using clean cloth etc. both inside & outside, Water line checking & leakage arresting (if any), checking of serviceablity incl repair / replacement of minor items / spares complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 16 | M&L for Servicing of Water Cooler of capacity 60/120 Ltr by proper cleaning with air pressure, tightening of Nuts / Bolts and wet cleaning using clean cloth etc. both inside & outside, Water line checking & leakage arresting (if any), checking of serviceablity incl repair / replacement of minor items / spares complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 17 | M&L for Servicing of Water Cooler of capacity 150/160 Ltr or higher capacity by proper cleaning with air pressure, tightening of Nuts / Bolts and wet cleaning using clean cloth etc. both inside & outside, Water line checking & leakage arresting (if any), checking of serviceablity incl repair / replacement of minor items / spares complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 18 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Water Coolers of capacy 40/80 Ltr incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) |
| 19 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Water Coolers of capacy 60/120 Ltr incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) |
| 20 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Water Coolers of capacy 150/160 Ltr or higher capacity incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) IMPORTANT NOTES for ITEM Nos 18 to 20 :1) Unit rate quoted is deemed to be inclusive of replacement guarantee of 2 Yrs for the entire Defect Liability Period. 2) Cost of any brazing, welding etc. work is also deemed to be included in the unit quoted rates.3) Anything missed out in the item specifications but technically required for efficient operation of the item / system is deemed to be included in the unit quoted rates.4) Quoted rate is also deemed to be inclusive of any minor spares as decided by the Engr-In-Charge.5) Original Purchase Vouchers & Test Certificates for the item is to be submitted to the Engr-In-Charge for checking/records purpose.6) Cost of filling of Refrigerant Gas (if any) shall be measured & paid separately under relevant items. |
| 21 | S&F OLP Relay Assy perfectly suitable for Water Cooler of different / any capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 22 | S&F Starting Capacitor 60/80 MFD etc. perfectly suitable for Water Cooler of different / any capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 23 | S&F Running Capacitor 25 MFD etc. perfectly suitable for Water Cooler of different / any capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 24 | S&F Thermostatic Switch perfectly suitable for Water Cooler of different / any capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 25 | S&F Blower Fan Motor of existing size / type / model etc. perfectly suitable for Water Cooler of capacities 40/80 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 26 | S&F Blower Fan Motor of existing size / type / model etc. perfectly suitable for Water Cooler of capacities 60/120 Ltrs incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 27 | S&F Blower Fan Motor of existing size / type / model etc. perfectly suitable for Water Cooler of capacities 150/180 Ltrs or higher capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 28 | S&F Push Cock Brass Chromium Plated 15 mm dia incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 29 | \"M&L for Overhauling and Servicing of Split type AC of capacity 1.5 / 2.0 TR of any make / tyep at different locations at AFA incl testing the unit complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge duly comprising of the following scope / tasks : (a) Complete Overhauling & Servicing.(b) Inspection by opening & washing the Condensor Coil and Cooling Coil with appropriate chemical using pressurized water jet complete. (c) Inspection and treatment of leakage of refrigerant in the system. (d) Checking of operation of Blower Motor, Condensor Motor and Swing Motor for noise free operation. (e) Oiling of Condensor / Blower Motors and checking for the earth continuity. (f) Inspection of all electrical parts / connections and rectification of any defects for smooth operation. (g) Checking of functioning of electronic Remote Control Unit to ensure satisfactory functioning of unit complete.(h) Inspection and treatment of leakage / condensate water from Indoor Unit.\" |
| 30 | \"Description all as per Item No 29.00 above but for Window type AC of capacity 1.5 / 2.0 TR complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge.\"IMPORTANT NOTE for ITEM Nos 29 & 30 : Major Spares / items required shall be measured & paid separately. |
| 31 | S&F Blower Motor for Indoor Unit of same specification / make / model / type as per existing one perfectly suitable for Split type AC 1.5 TR capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 32 | S&F Blower Motor for Indoor Unit of same specification / make / model / type as per existing one perfectly suitable for Split type AC 2.0 TR capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 33 | S&F Condensor Fan Motor with Blade for Outdoor Unit of same specification / make / model / type as per existing one perfectly suitable for Split type AC 1.5 / 2.0 TR capacity incl testing & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 34 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Split type AC 1.5 TR capacity incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement) |
| 35 | Supply, install, commissioning & testing of Hermetically Sealed Compressor Unit perfectly suitable for Split type AC 2.0 TR capacity incl making electrical, refrigerant piping etc. connections incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : Copeland / Danfoss / kirloskar / Blue star / Voltas / Samsung / LG (As per site requirement)IMPORTANT NOTES for ITEM Nos 34 & 35 :1) Unit rate quoted is deemed to be inclusive of replacement guarantee of 2 Yrs for the entire Defect Liability Period. 2) Cost of any brazing, welding etc. work is also deemed to be included in the unit quoted rates.3) Anything missed out in the item specifications but technically required for efficient operation of the item / system is deemed to be included in the unit quoted rates.4) Quoted rate is also deemed to be inclusive of any minor spares as decided by the Engr-In-Charge.5) Original Purchase Vouchers & Test Certificates for the item is to be submitted to the Engr-In-Charge for checking/records purpose.6) Cost of filling of Refrigerant Gas (if any) shall be measured & paid separately under relevant items. |
| 36 | S&F Condensor Unit for Outdoor Unit of Split type AC of capacity 1.5 TR / 2.0 TR as per existing specification / make / mode/ / type etc. including brazing work and testing on full load for satisfactory functioning incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 37 | S&F Oscillation Motor for Indoor Unit of Split type AC of capacity 1.5 TR / 2.0 TR as per existing specification / make / mode/ / type etc. including testing on full load for satisfactory functioning incl taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 38 | M&L for repair of unserviceable PCB with cord / cordless Remote Control Unit of any type / make / model of Split AC of capacity 1.5 TR / 2.0 TR including replacement of unserviceable spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 39 | S&F PCB with Remote Control Unit complete perfectly suitable for any type / make / model of Split AC of cap 1.5 TR / 2.0 TR with features of digital display, mode selection, timer, temperature control etc.incl battery & testing for satisfactory functioning & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 40 | S&F Hand Set Remote perfectly suitable for any type / make /model of Split AC of capacity 1.5 TR / 2.0 TR with features of digital display, mode selection, timer, temperature control etc. incl battery & testing for satisfactory functioning & taking down old unsv / damaged one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 41 | M&L for repair of Single Phase Voltage Stabilizer of capacity 0.5 KVA to 3 KVA any type / make / model / specification etc. with & including replacement of any faulty parts like Transformer, PCB, Relays, Voltmeters, Selector switches etc. to make the stabilizer completely serviceable incl testing for satisfactory functioning & taking down old unsv / damaged spare parts etc. complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 42 | M&L for repair of Single Phase Voltage Stabilizer of capacity above 3 KVA to 5 KVA any type / make / model / specification etc. with & including replacement of any faulty parts like Transformer, PCB, Relays, Voltmeters, Selector switches etc. to make the stabilizer completely serviceable incl testing for satisfactory functioning & taking down old unsv / damaged spare parts etc. complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 43 | S&F Copper Tubing flexible of dia 5/8\"including heavy duty nitrile rubber insulation incl testing for satisfactory functioning & taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 44 | Description all as per Item No 43.00 above but of dia 3/8\" |
| 45 | Description all as per Item No 43.00 above but of dia 1/2\" |
| 46 | Description all as per Item No 43.00 above but of dia 1/4\" |
| 47 | S&F heavy duty Nitrile Rubber Foam Insulation of size / type / thickness / density / thermal conductivity etc. as per existing & perfectly suitable for insulation of Copper Tubing flexible type of sizes for Split type ACs of capacity 1.5 TR / 2.0 TR incl PVC Cable ties & taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 48 | S&F flexible type condensate water drain out pipe suitable for Indoor Unit of Split ACs as per existing type / model etc. incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 49 | M&L for dismantling, shifting and refixing of Window / Split type ACs of any make / model / capacity from one location to another location / place under AoR of AFA with & including gutties / fasteners, core cutting in brick / stone walls as required incl arrangement of required T&P,positioning of condensing unit and brazing work incl connection of drain pipe, making good the disturbed surfaces including making good the disturbed surfaces and testing the unit for satisfactory functioning complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. IMPORTANT NOTE :- (i) Refrigerant if required to be charged shall be measured and paid separately under relevant item.(ii) Copper tubing flexible, if required to be charged, shall be measured and paid separately under relevant item. (iii) Nitrile Rubber Foam Insulation, if required to be changed, shall be measured and paid separately under relevant item.(iv) Flexible type water drain out pipe, if required to be changed, shall be measured and paid separately under relevant item.(v) Quoted rate is deemed to be inclusive of all the T&P such as Aerial Work Platforms, Scaffolding, Ladders, Core-cutting Machines, Brazing torch, Pipe cutters, Transportation etc. for repair / replacement / shifting etc. of ACs whereever required. |
| 50 | Supply and topping up / charging of Refrigerent gas (R-22) for ACs as per standard practice incl leakage testing complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 51 | Supply and topping up / charging of Refrigerent gas (R-410) for ACs as per standard practice incl leakage testing complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 52 | Supply and topping up / charging of Refrigerent gas (R-32) for ACs / Water Coolers as per standard practice incl leakage testing complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 53 | Supply and topping up / charging of Refrigerent gas (R-134a) for Refrigerators as per standard practice incl leakage testing complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 54 | \"M&L for Pressure Testing of Split / Window ACs of any capacity complete with filling of Nitrogen gas after flushing out the system free from any oil / grease etc. cheking for leakages if any in the refrigerent system making good the leaking parts with necessary brazing / welding, ensuring leak proof system and testing for satisfactory performance complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. NOTE : Refrigerant, if required to be changed, shall be measured and paid separately under relevant item.\" |
| 55 | S&F Single Pole & Neutral Sheet Metal Enclosure with a two pin & earth plug & socket complete with one single pole MCB, \"C\" Curve, 10 KA, 20A incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : L&T/LEGRAND/ABB/SIEMENS |
| 56 | S&F Single Phase Modular type Motor Starter 20 to 32 Amps, 240 Volts, 50 Hz for split AC including cover plate and PVC surface box of suitable size as required at site incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : L&T/LEGRAND/ABB/SIEMENS |
| 57 | M & L for sub-main wiring alongwith earth wire of size (2 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. incl taking down old unsv one complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex/KEI. Make of Conduit : Precision/Polycab/Finolex/Modi/SudhakarNOTE : 1) Two runs of PVC wire, One run of Earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Cost of Modular metal flush boxes (if any for junction inspection) is deemed to be included in the unit quoted rates. 3) Cutting chases & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps/saddles of appropriate sizes with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire. 6) Cost of taking down old unsv wiring incl making good the disturbed surfaces is deemed to be included in the unit quoted rates. |
| 58 | S&F rigid non-metallic PVC Conduit (medium grade) of size 25 mm dia on walls / floor / roof etc., ISI Marked of colour as approved by Engr-In-Charge inclusive of connected fittings with & including necessary fixing arrangements such as PVC saddles, couplers, lock nuts, pipe hooks etc. suitable for condensate water line of ACs incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make of Conduit : Precision/Polycab/Finolex/Modi/Sudhakar |
| 59 | S&F rigid non-metallic PVC Conduit (medium grade) of size 40 mm dia on walls / floor / roof etc., ISI Marked of colour as approved by Engr-In-Charge inclusive of connected fittings with & including necessary fixing arrangements such as PVC saddles, couplers, lock nuts, pipe hooks etc. suitable for condensate water line of ACs incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make of Conduit : Precision/Polycab/Finolex/Modi/Sudhakar IMPORTANT NOT FOR ITEM Nos 58 & 59 : Quoted rate is deemed to be inclusive of all the T&P such as Aerial Work Platforms, Scaffolding, Ladders, Core-cutting Machines, Brazing torch, Pipe cutters, Transportation etc. |
| 60 | S&F Running Capacitor 2.5 mfd, heavy duty, 230V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 61 | S&F Running Capacitor 4 to 6 mfd, heavy duty, 230V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 62 | S&F Running Capacitor 36 mfd, heavy duty, 230 / 415 V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 63 | S&F Running Capacitor 45 mfd, heavy duty, 230 / 415V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 64 | S&F Running Capacitor 52+4 mfd, heavy duty, 230 / 415V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 65 | S&F Running Capacitor 55 mfd, heavy duty, 230 / 415V, AC supply for Air Conditioners of any make / model / type etc. incl taking down old unsv one complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. Make : Havells / Tibcon / Bajaj |
| 66 | S&F Metal Clad 3 Pin Plug Top 20 Amps, 230 Volt, Single Phase incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : L&T/LEGRAND/ABB/SIEMENS |
| 67 | S&F Metal Clad 3 Pin Socket 20 Amps, 230 Volt, Single Phase incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : L&T/LEGRAND/ABB/SIEMENS |
| 68 | S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : L&T/LEGRAND/ABB/SIEMENS |
| 69 | S&F Brass Flair nuts 1/2 to 1/4\" including brazing taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 70 | S&F Brass Flair nuts 3/8 to 5/8\" including brazing taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. |
| 71 | S&F PVC insulated 3 core FRLS round flexible copper PVC insulated sheathed cable 1100 V grade of size 2.5 sq mm incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : POLYCAB / FINOLEX / KEI |
| 72 | S&F PVC insulated 3 core FRLS round flexible copper PVC insulated sheathed cable 1100 V grade of size 4.0 sq mm incl taking down old unsv one complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. Make : POLYCAB / FINOLEX / KEI |
| 73 | M&L for attending complaints for electrical faults, water leakages from Indoor Units of Split ACs, low cooling, making noise etc. of Desert Coolers, Water Coolers, Refrigerators, Deep Freezers and Air Conditioners of any type / capacity model etc. for repair as required at site including repairing of normal faults due to burnt terminals of appliances, blockage of filters, low level of refrigerant, loose fittings / loose connections etc. complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge. \"NOTE : -(i) Quoted rate is deemed to be inclusive of all the T&P such as Aerial Work Platforms, Scaffolding, Ladders, Core-cutting Machines, Brazing torch, Pipe cutters, Transportation etc. (ii) Complaints of Urgent Nature shall be attended round the clock including Sundays & holidays to resolve the complaints to entire User Satisfaction & intimation / information about the Urgent complaint can be given through telephonic / electronic mode.(iii) Minimum two Skilled Ref Mech as Tradesman and two Semi-Skilled Ref Mech as helper shall report to I/C of AC Sec of AGE E/M AFA Hyd on a daily basis before 0900 Hrs for attending complaints and shall give feed-back / complaint status daily by 1700 Hrs.(iv)Complaints given to Contractor / Rep shall be rectified within 24 Hrs. (v)Penalty @ Rs 1000/- per complaint shall be deducted for not-attendance of the complaints and those completed beyond 24 hours without any valid justification.(vi)Complaints of repeat nature shall not be paid for separately unless justified & agreed by the Dept. Decision of Engr-In-Charge shall be Final & Binding in this regard.\" |
| 74 | Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 175 V to 250 V with Digital Voltmeter & O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 4.0 KVA suitable for 1.5 TR Inverter AC incl electric connection complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge incl taking down old unsv one & depositing to MES Storeyard. Make : APLAB/VENER-7/SINETRAC/V-GUARD/ITE GURGAON/AE |
| 75 | Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 175 V to 250 V with Digital Voltmeter & O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 5.0 KVA suitable for 2.0 TR Inverter AC incl electric connection complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge incl taking down old unsv one & depositing to MES Storeyard. Make : APLAB/VENER-7/SINETRAC/V-GUARD/ITE GURGAON/AE |
| 76 | Supply, install, commissioning & testing of Wall Mounting Auto-Changeover for Air Conditioners with & incl Timer / Cyclic Timer with Temperature Controller as per following specificationsperfectly suitable for 2 x 1.5 Ton / 2 x 2 Ton Split type ACs incl electric connection complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge incl taking down old unsv one.Input Voltage:230 +/- 15%, 50 HZ, Output Voltage :230 V, 25 Amp separate for 2 A/Cs.Protections: O/V & U/VO/P Contacts : O/P contact for bothACs.Indications : AC-1: ON , AC2 : ON, Delay, Over Voltage Trip, Under Voltage Trip, Manual Mode and Auto Mode. ON delay time : 2 minute & 30 Sec.Changeover time delay : 4 / 6 / 8 Hrs (As per actual Site Requirement)Important Notes for Item Nos 74 TO 76 :(i) Technical Specifications/particulars etc. of the Items is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer.(ii) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.(iii) All PVs, Test Certificates, Guarantee / Warranty Certificates is to be submitted in Original to the Engr-In-Charge for checking / records. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail