| 1 | Supply,laying,jointing,connecting,testing underground XLPE insulated,PVC seathed, armoured heavy duty electric LT cable,1100 volts grade with aluminium stranded conductor,10 sqm 4core,laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands,crimping type cable lugs,sockets etc.complete and taking down the existing cable all as specified and directed. |
| 2 | All as per description of item No.01.00 here-in-before but Cross sectional area 70 sq mm, 3.5 core |
| 3 | S&F in repair of LED street light fitting 70 watts,not less than 120Im/watt with pressure die-cost aluminium housing along with prismatic polycarbonate modular secondary lens optics for street light applicationwith IP66 ingress protection and impact resistance of IK08/IK074KV inbuilt surge and 10KV external surge protection with Top/Bottom opening driver cover for easy maintenance and soft illumination effect and powder costed complete on fixing on GI Octogonal Pole of 6/7 mtrs height all as specified and as directed. Make: Crompton cat No CRP-406=70-57-HL2-GL-NSG and Make: Havells Cat No ENDURASUNDOWNSL-70WLED 765PASYBOTG or equivalent of other makes as specified in PS |
| 4 | Material and Labour for cutting existing BT / PCCroad of size 45cm x 60cmfor taking out/laying of underground cable/pipe and including necessary earth work and refilling the same in layers well ramming including watering as required and matching with the existing surface with 200mm thick PCC 1:2:4 type B1 and curing the same with wet gunny bagsand removing debris to a distance not less than 50m complete all as specified and as directed . |
| 5 | Supply, Laying in repair GI tubing light grade for encasing LT cables for mechanical protection, laid in trench /floor/under road or along the pole by means of M.S.F.I. clamps with necessary bolts nuts and washers etc of size 40 mm dia, complete all as specified. |
| 6 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less thab 1.5 Meter below normal ground level connected to GI wire of dia 4mm as main earthing lead (upto 7.5 m length from earth electrode to test point) by means of galvanised iron or steel bolts, nuts, check nuts & GI washersand GI tubing 15 mm bore medium grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type B1 as in cover slab 54 x 54 x 5 cm including 8mm dia MS TMT bars @ 150 mm c/c as in reinforcement with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (Light Grade) for watering and funnel, charcoal or coal and salt in alternate layers including excavation earth work in any type of soil, RFR and removal of surplus soil complete all as specified and directed electrical plate No. 3 of SSR part - I complete all as specified and as directed including taking out old earthing . |
| 7 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I of 2009 connected to earthing test pointor disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe for watering and funnel, GI Pipe medium grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1. |
| 8 | S & F in replacement street light timer, single phase for 8 KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply, install,test and commissioning of CPRI approved LT panel, outdoor type, varmin and dust proof cubical type front and rear opening with locking arrangementmade out of CRCA sheet 3 mm thickangle iron frame fixed on floor duly powder coated, housing with aluminium busbar 500 Amps capacity for 3 phase and neutral, cable connections, including voltmeter 0 to 500 volts, Ammeter 0 to 300 Amps, indicating lamps, selectorswitches, including necessary wiring ,Degree ofProtection IP 54, floor mounted free standing type, suitable for mounting following switchgear and accessories in the panel alongwith PCC (1:3:6) type C1, bedding upto height of 30cm above ground level complete incl taking down old LT Panel all as directed.all as directed by Engineer-in-Charge Note :- (a) Rates for switch gears such as MCCB/MCBs shall be deemed to be Included in the above Item.(b)Fixing charges, connecting charges all deemed to be included . (c)Rates for voltmeter, ammeter selector switches, indicating lamps, CTS,bushbars, connecting cables are deemed to be included in the above items. Proper Foundation with PCC also included in above rate.(a). 4 Pole MCCB 200Amp ,50Hz 415 V with ,Adjustable thermal and magnetic repturing capacity 36 KA-01 Nos(Incomming)(b).MCCB 160Amps, 4 pole, 415 volts, 50HZ 26KA.- 01(Nos) (Outgoing)(c).MCCB 100Amps, 4 pole, 415 volts, 50HZ 26KA.- 03(Nos) (Outgoing)(d).MCCB 63Amps, 4 pole, 415 volts, 50HZ 26KA.- 04(Nos) (Outgoing)(e).MCB 40 Amps, 2 pole, .- 04(Nos) (Outgoing) |
| 10 | Supply, install,test and commissioning of CPRI approved LT panel, outdoor type, varmin and dust proof cubical type front and rear opening with locking arrangementmade out of CRCA sheet 3mm thickangle iron frame fixed on floor duly powder coated, housing with aluminium busbar 400 Amps capacity for 3 phase and neutral, cable connections, including voltmeter 0 to 500 volts, Ammeter 0 to 250 Amps, indicating lamps, selectorswitches, including necessary wiring ,Degree ofProtection IP 54, floor mounted free standing type, suitable for mounting following switchgear and accessories in the panel alongwith PCC (1:3:6) type C1, bedding upto height of 30cm above ground level complete incl taking down old LT Panel all as directed.all as directed by Engineer-in-Charge Note :- (a) Rates for switch gears such as MCCB/MCBs shall be deemed to be Included in the above Item.(b)Fixing charges, connecting charges all deemed to be included in the above items. (c)Rates for voltmeter, ammeter selector switches, indicating lamps, CTS,bushbars, connecting cables are deemed to be included in the above items. Proper Foundation with PCC also included in above rate.(a). 4 Pole MCCB 200 Amp ,50Hz 415 V with ,Adjustable thermal and magnetic repturing capacity 36 KA-01 Nos(Incomming)(b).MCCB160Amps, 4 pole, 415 volts, 50HZ 26KA.- 01(Nos) (Outgoing)(c).MCCB100Amps, 4 pole, 415 volts, 50HZ 26KA.- 03(Nos) (Outgoing)(d).MCCB 63Amps, 4 pole, 415 volts, 50HZ 26KA.- 02(Nos) (Outgoing)(e).MCB 40 Amps, 2 pole, .- 02(Nos) (Outgoing) |
| 11 | M & L for excavation and Demolition the old Existing RCC polescomplete with Pcc foundation and removal of all debiries to outside MOD land and making good disturbed surfacesallasspecified and asdirected . |
| 12 | Supplying, installation of7 Mtr high hot dip galvanized iron Octogonal pole 3.0mm wall thickness, with bottom size 130 mm diameter, top size 70mm diameter with 3mm thick base plate of size 200x200x12 mm, pole fabricating out of medium grade tapered pole octagonal cross section and shall be continuosly tapered with single longitudinal conforming to BSEN 100 25/100 27 with base plate Fe 410 conforming to IS 2062 of suitable thickness with provision of 4 Nos foundation bolts. The pole shall be galvanized as per IS 4759/BSEN1461 standards/housing with aluminum busbar, inbuilt junction box, complete end termination, including single luminary hallowarm 42mm diameter, 2.6mm thick, 1 Meter long, with grouting of base plate in concrete foundation 1:2:4 concrete including excavation, earth work, refilling etc RCC foundation as recommended by OEM,pole Nos shall be marked on each pole with synthetic enamel paint with black backroundcomplete all as specified and directed. Note:-(i) Every pole shall be prewired from Junction box to fixture with 1.5 Sqmm 3 core copper conductor sheathed wirefor Phase, neutral and Earth and necessary suitable arrangement for mounting fitting on pole).(ii) Quoted rate shall include including 1A MCB SP B series,3core 1.5sqmm cable, Earth work and nessaryexcavation i.e reinforcement,holding down bolts, nuts, washer of suitable size etc complete as per manufactures instructions.(iii) Provision of light fittingsshall be measured and paid seperately here-in-after. (iv) Contractor shall submit Drawings of Octoganal Poles&its foundationfor approval of GE. (v) Rate of RCC foundation shall deemed to be inluded in quated rate . |
| 13 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38 mm confirming to IS 14930 -II and ISI Marked all specified and directed. |
| 14 | Supply & lay cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 63 mm OD and ID 50 mm confirming to IS 14930 -II and ISI Marked all specified and directed. |
| 15 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in sofg / loose soil |
| 16 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cmsoil / hard dense soil. |
| 17 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point for soft/hard soil . |