| Sl. No. | Item Description |
| 1 | Periodical maintenance incl Inspection, maintenance and servicing of DG sets of the following capacities DG sets incl alternator, electric panel board, AMF panels, connection of DG Set for following mentioned checks incl \"B\" checks of DG set for smooth functioning and carrying out maintenance complete as directed :- `B\" CHECK shall be done as directed by engr-in chargeTask to be done(i)Checking engine oil level and topping up, replacement as and when required Note: Oil for top up/ replacement shall be measured and paid separately under relevant item.(ii) Checking and adjusting the belt for tension and replacemnt of belt, reqd NOTE: Belt shall be measured and paid separately(iii) Checking of oil bath air cleaner level(iv) Checking of exhaust system for leakage(v) Draining of sediment from fuel filter and fuel tank(vi) Checking engine alternator coupling, mounting boltsand alignment.(vii)Tightening all nut, bolts, in alternator terminal block.(Viii)Checking ofalternator carbon brush, connection conditions in alternator(ix)Checking and tightening of all connection in DC control wiring.(x) replacing the following accessories of DG set(a) Oil filter.(b) Air filter.(c) Fuel filter.(d) By pass filter.(e) Engine oil . |
| 2 | (f) coolent.(Engine oil & coolent shall be measured and paid separately.)(xi)Checking ofall radiator rubber hose and replacementif required.NOTE : Hose pipes shall be measured and paid separately(xii)Checking of oil pressure, water and oil temperature gauge, sensor(xiii)Checking anti vibration mounting and replacement if required.NOTE: Anti vibration pad shall be measured and paid separately, if replaced.(xiv) Checking throttle linkage(xv) Checking battery for cell test, electrolyte level, gravity and topping up to required levelNote: The battery\"s distilled water shall be measured and paid separately, if re-filled.(xvi) Routine check / tightning of connections of panel, switch, MCCB, main switch, all contactor, engine control unit and functioning of AMF system(xvii) complete cleaning of DG set(xviii) Replacing lubricant oil filter element with `O\" ringNote: Item shall be measured under relevant item.(d) Items shall be measued & paid separetlyNOTES i) `B\" check kit, coolant shall be measured and paid seperately under relevant item as supply only.ii)Lubricant oil shall be measured and paid separately under relevant item. (iii)Necessary servicing should be done after an interval of running 500 Hrs or six months which will be earlier |
| 3 | 400 KVA Make : M&M |
| 4 | 320 KVA Make : Kirloskar |
| 5 | 250 KVA Make : M&M |
| 6 | 200 KVA Make : Ruston, Kirloskar |
| 7 | 180 KVA Make : Crompton Greaves, |
| 8 | 160 KVA, MAKE:Cummins, M&M |
| 9 | 125/100 KVA,MAKE: Kirloskar, Ashok Leyland ,CG |
| 10 | 82.5 KVA Make: Crompton Greaves |
| 11 | 63/62.5, MAKE: Kirloskar, Mahindra, Ashok Leyland & Crompton Greaves |
| 12 | 15/12.5KVA,, MAKE:Crompton Greaves, Kirloskar |
| 13 | 10/7.5KVA,MAKE: Mahindra, Kirloskar |
| 14 | Disconnecting all the connections from alternator of DG Set of 7.5 KVA to15 KVA Capacity removing the alternator from foundations/ enclosure , transporting to workshop, dismantling completely including stator, rotor, removing burnt winding and replacing with new copper winding, insulation, unserviceable parts, bearing cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed. |
| 15 | Disconnecting all the connections from alternator of DG Set of 62.5 KVA to 180 KVA Capacity removing the alternator from foundations/ enclosure , transporting to workshop, dismantling completely including stator, rotor, removing burnt winding and replacing with new copper windinginsulation, unserviceable parts, bearing cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed. |
| 16 | Disconnecting all the connections from alternator of DG Set of 200 KVA to400 KVA Capacity removing the alternator from foundations/ enclosure , transporting to workshop, dismantling completely including stator, rotor, removing burnt winding and replacing with new copper winding , insulation, unserviceable parts, bearing cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed. |
| 17 | Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacitiesDG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers ofradiator assembly, cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the DG set of capacity up to 400 KVA, complete all as specified and directed by Engr-in-Charge. |
| 18 | M & L for replacement of undermentioned UNSV/ defective spare parts of DG Sets of capacity 7.5 KVA to 15 KVA, Make: Cummins / Kirloskar/ Mahindra or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed. |
| 19 | Rubber Hose any type |
| 20 | V Belt |
| 21 | Water Pump assembly |
| 22 | Solenoid Switch |
| 23 | Voltage monitoring Relay |
| 24 | Flexible steel braided Fuel pipe having banjo nipple & Maching Bolt at both ends of existing length |
| 25 | AVR |
| 26 | Fuel Injection Pump Assembly |
| 27 | M & L for replacement of undermentioned UNSV/ defective spare parts of DG Sets of capacity 62.5KVA to 180 KVA, Make: Cummins / Kirloskar/ Mahindra or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed. |
| 28 | Rubber Hose any type |
| 29 | V Belt |
| 30 | Water Pump assembly |
| 31 | Solenoid Switch |
| 32 | Voltage monitoring Relay |
| 33 | Flexible steel braided Fuel pipe having banjo nipple & Maching Bolt at both ends of existing length |
| 34 | AVR |
| 35 | Fuel Injection Pump Assembly |
| 36 | M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 200 KVA to 400 KVAMake :Kirloskeror any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed. |
| 37 | Rubber Hose any type |
| 38 | V Belt |
| 39 | Water Pump assembly |
| 40 | Solenoid Switch |
| 41 | Voltage monitoring Relay |
| 42 | Flexible steel braided Fuel pipe having banjo nipple & Maching Bolt at both ends of existing length |
| 43 | AVR |
| 44 | Fuel Injection Pump Assembly |
| 45 | M&L forOil Pressure gauge of DG set complete incl necessary connections & taking down/ out old UNSV complete. |
| 46 | M&L forRPM gauge of DG set complete incl necessary connections& taking down/ out old UNSV complete. |
| 47 | M&L for Analogue DC Amp meter cap 20 Amp of DG set complete incl necessary connections& taking down/ out old UNSV complete. |
| 48 | M&L for Digital voltmeter suitable upto 415 volt of DG set complete incl necessary connections& taking down/ out old UNSV complete. |
| 49 | Dismantling , removing the self starter 12 volt from the engine of DG Sets upto 200 KVA opening up, over hauling/ repairing/ servicing, replacement of defective undermentioned parts and assembling, refixing and testing for proper functioning : |
| 50 | Dismantling , removing the self starter 24 volt from the engine of DG Sets from above 200 KVA to upto 400 KVA opening up , over hauling/ servicing, replacement of burnt winding, carbon brushes with holders assembling back, refixing and testing for proper function complete all as directed. |
| 51 | Dismaintling, radiator assembly from the engine of 7.5 KVA to 200 KVA capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing/ descaling, removing blockages arresting leakages, assembling back incl necessary welding brazing as required, refixing , reconnecting and testing for proper functioning : |
| 52 | Dismaintling, radiator assembly from the engine of 200 KVA to 400 KVA capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing/ descaling, removing blockages arresting leakages, assembling back incl necessary welding brazing as required, refixing , reconnecting and testing for proper functioning : |
| 53 | Cleaning of fuel tank of DG set of 7.5 KVA to 200 KVAcapacities by disconnecting fuel pipes connection, draining out fuel from the tank, cleaning of tank, replacement of chocked all fuel pipe Connection of suitable diameter, painting of fuel tankwith synthetic enamel paint, one coat after cleaning, scrubbing the surfaces incl writing with paint the capacity, serviceability of fuel gauge complete for following DG Sets. |
| 54 | Cleaning of fuel tank of DG set of 200 KVA to 400 KVAcapacities by disconnecting fuel pipes connection, draining out fuel from the tank, cleaning of tank, replacement of chocked all fuel pipe Connection of suitable diameter, painting of fuel tankwith synthetic enamel paint, one coat after cleaning, scrubbing the surfaces incl writing with paint the capacity, serviceability of fuel gauge complete for following DG Sets. |
| 55 | M & L for painting of DG sets top frame and bottom frame, inner side base of capacity 7.5 KVA to 63 KVAwith existing colour with spray painting (synthetic enamel paint two coats) including cleaning of rusted space of the body all as specified and directed by Engr-in-Charge |
| 56 | M & L for painting of DG sets top frame and bottom frame, inner side base of capacity 100 KVA to 250 KVAwith existing colour with spray painting (synthetic enamel paint two coats)including cleaning of rusted space & prepration of surfaces of the body all as specified and directed by Engr-in-Charge |
| 57 | Replacement of coolant incl taking out old , Supply & Pour in refilliing of coolant, K cool Supper plus 50-50 Premix complete.Note: The net qty of coolant shall be measured for payment. |
| 58 | Supply & Pour in refilliing of battery distilled water |
| 59 | Replacement of Engine oil incltaking out old, Supply & fill in refilling of engine oil 15w40 superior quality engine oil complete. |
| 60 | M & L for replacement of steel hinges of door of various capacity of DG Set 100 KVA to 400 KVA complete with nuts and bolts reqd/ welding as reqd at site. |
| 61 | Replacement of Existing Acoustic enclosure of DG set upto 200 KVA complete by removing Alternator, Engine & all accessories, pipe, cable connections and fixing in new Acoustic enclosure with inbuilt fuel tank, exhaust siencer made of Powder coated CRCA sheet 16 gauge min having suitable ISMC channel for base and fixing of Engine & Alternator.Cenopy shall have the contractor shall check size of engine & alternator of existing DG Set at site. doors - 04 Nos with steel hinges, high quaity EDPN/ neoprene gasket, acoustic insulation material complete to comply CPCB norms of 75dBA at 1 Mtr and fuel, cable connections complete for satisfactory testing of DG set incl any type of T&P, hydra, T&P charges complete. |
| 62 | S&F in repair SMPS based 12Volt/10 Amp float cum boost type battery charger suitable for input voltage 220 V and output voltage 12 Voltage having NO & NC terminals with necessary electric connections in DG control panel complete all as specified and dircted by engineer-in-charge. |
| 63 | S&F in repair SMPS based 24Volt/20 Amp float cum boost type battery charger suitable for input voltage 220 V and output voltage 24 Voltage having NO & NC terminals with necessary electric connections in DG control panel complete all as specified and dircted by engineer-in-charge. |
| 64 | M&L for Overload relay with range 3-5 Amp suitable for 3 phase connections complete all as specified & directed. |
| 65 | M&L for Annuciator window suitable to work on 12/24Volt DC having button for reset, test, Acknowledgeand features suitable for DG set faults 12 Nos minimum having required windows complete of size suitable to fit in existing panel complete all as specified & directed. |
| 66 | Attending complaints of not working / any error / mechanical/ electrical/ electro-mechanical of DG sets/ AMF panel up to 400 KVA within3 hours after intimation to the contractor by the Department. Complaint shall be attended by qualified mechanic all as specified and as directed by Engineer - in - charge.If contractor fail to attend the complaint of DG set within 3 hours, recovery @ Rs. 500/- per hour shall be imposed upon the contractor. Note: Major parts required to be replaced shall be measured and paid separately. |
| 67 | M&L for battery terminals with nut & bolt heavy duty suitable for upto 180 Ah maint free DG set battery complete. |
| 68 | S&Fin repair battery 12 volts 150 AH maint free typecomplete all as specified and as directed by Engineer in Charge. |
| 69 | S&Fin repairbattery 12 volts 180 AH maint free type complete all as specified |
| 70 | S&Fin repairbattery Battery Lead of size 35 sqmm made of copper of superior quality having length 60 cm min complete. |
| 71 | S&F in repaironload changeover switchwith steel sheet enclosure 4 pole,400 A,415Volt 50 Hz all as specified and as directed by Engineer -in- charge. |
| 72 | S&Fin replacement 3 pole contactors 40 Amps with coil voltage 240 Volts. Note for item No. 36 to 38:- The new contractor, contractor coil shoul be of same model as per existing size to avoid any alteration/modification during replacement. |
| 73 | S&Fin replacement 4 pole contactor MCX 41 of make L&T, coil voltage 220/240/415 volts, 2 NO + 2 NC complete with spreader link kit as reqd at site complete all as directed by Engr-in-Charge. |
| 74 | S&Fin replacement 4 pole contactor MCX 44 of make L&T, coil voltage 220/240/415 volts, 2 NO +2 NC complete with spreader link kit as reqd at site complete all as directed by Engr-in-Charge. |
| 75 | S&F Add on Aux contact block having 1 NO + 1NC suitable for MCX 34 to MCX 44 complete all as directed. |
| 76 | S&F spare coil for contactor MCX 41 to MCX 44, coil voltage 240/415V as reqd at site complete. |
| 77 | Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make. |
| 78 | Supply and fix in replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter.Make L&T/ GIC/ Legrand/ C&S/Minilec or equivalent. |
| 79 | M&L for fixing of MSCRCA sheet powder coated of 2 to 3.15mm thickness , cut to shape and size required as per LT panel located at site including welding of hinge joint to sheet for fixing complete all as per directed by Engineer-in-Charge.Note: The contractor shall have to takemeasurement of panel at site for new sheet complete. |
| 80 | S&Fof Micro Processor controller unit with RS 485, RS232 connector port, IP/OP serial connector able to work on 8 to 35V dc, having suitable ports for DC conn, AC suppply, alarms, auto start conforming to model No i.e. EC-RXA-V2 Make C&S / KG 545 of Kirloskar / DSE or any other updated make/model matching with features of existing controller suitable for DG set of cap 7.5 kVA to 400 kVA |
| 81 | Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacitiesDG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers ofradiator assembly, cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the DG set of capacity up to 400 KVA, complete all as specified and directed by Engr-in-Charge. |
| 82 | Repair and replacement of the UNSV Fuel injection pump assy install ,Test & commisioning ofFuel injection pump assy inclusive of injector system for following DG set, complete all as specified and directed by Engr-in-Charge :-Note :- Calibration shall be performed before erection of FIP.(a) 7.5 KVA to 15 KVA |
| 83 | Repair and replacement of the UNSV Fuel injection pump assy install ,Test & commisioning ofFuel injection pump assy inclusive of injector system for following DG set, complete all as specified and directed by Engr-in-Charge :-Note :- Calibration shall be performed before erection of FIP.(a) 62.5 KVA to 180 KVA |
| 84 | Repair and replacement of the UNSV Fuel injection pump assy install ,Test & commisioning ofFuel injection pump assy inclusive of injector system for following DG set, complete all as specified and directed by Engr-in-Charge :-Note :- Calibration shall be performed before erection of FIP.(a) 180 KVA to 4000 KVA |
| 85 | Overhauling of injector nozzles of capacity 7.5 KVA to 15 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 86 | Overhauling of injector nozzles of capacity 62.5 KVA to 180 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 87 | Overhauling of injector nozzles of capacity 180 KVA to 400 KVA test & commisioning of injector nozzles inclusive of injector system, complete all as specified and directed by Engr-in-Charge. |
| 88 | Repair/ Servicing /replacement of old UNSV parts of DG Set upto 400 KVA, Make Mahindra & Mahindraby disconnecting, taking down following parts from the engine, machining to engine block to make surface smooth and of suitable size to match with liner complete and replacing the UNSV parts with new partsand it functional complete all as specified and as directed.Note: The parts shall be measured & paid separately. |
| 89 | Cylinder liner |
| 90 | Piston complete with pin |
| 91 | Piston ring set |
| 92 | Cylinder head gasket |
| 93 | Joint kit complete |
| 94 | \"O\" ring kit complete |
| 95 | Connecting rod big end bearing |
| 96 | Connecting rod bearing small end |
| 97 | Valve inlet and exhaust |
| 98 | Valve seat |
| 99 | Head Valve Guide |
| 100 | M&L for Earth continuityconductor or main earth leadfixed on wall on batten or recess or chases or burried in groundor drawn in conduit / pipe or fixed to pole or any other indicatedas required on ground for 25x3 mm aluminium strip complete all as specified and as directed. |
| 101 | M&L for Earth continuityconductor or main earth leadfixed on wall on batten or recess or chases or burried in groundor drawn in conduit / pipe or fixed to pole or any other indicatedas required on 35 Sqmm multi stranded PVC sheathed copper cable all as specified and directed |
| 102 | M&L in replacement Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 32x6 mm as earthing strip by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth stripprotected by 40mm dia GI light grade pipe, PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GIwatering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. (Note: The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner (2) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor. |
| 103 | Periodical maintenance of Fire alarm system installed at MAP \"G-1\" pocket with 01 No Main Fire control panel (4 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter01 No at Ground floor of each one block ) incl making system fully functional on commencement of work by deploying suitable Technician.Technician will clean, inspect, check the functionality, tight connections testing including carrying out repairs initial for Fire Alarm system having Intelligent addressable fire alarm system control Panel, control loop panel and flow chart based programmable RTU, Loop card, Main board, LCD display, Printer Panel, AC filter, Lead acid batteries, UPS, Multisensor, sounder, MCP, Heat detector, smoke detector, Manual Call Point, Repeater Panel, Zone monitor Module, Loop Isolator, Amplifier, connection wires, batteries andLoud speakers, annuciator system for the trouble free and efficient functioninig of the entire fire alarm system all as directed and as per Guideline as mentioned in Tender particular specifications. The parts to be replaced shall be measured and paid separately.Note: Major defective parts replaced shall be measured under Item S No 64 to 106. The quoted rate includes the cost of minor parts.A report regarding satisfactory functioning of system shall be submitted by the contractor on letter pad monthly basis all as directed by Engineer-in-Charge. |
| 104 | All as per above item No 56 but for Fire alarm installed at MAP \"H\" pocket withMA in Fire alarm control panel - 02 No (10 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower.and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter01 No for one block each ) for complete H pocket complete. |
| 105 | All as per above item No 56 but for Addressable Fire alarm system installed at MAP \"G-2\" pocket with Main FIre alarm control panel - 01 No (18 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower.and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter01 No for one block ) complete G-1 pocket ) complete. |
| 106 | All as per above item No 56 but for Addressable Fire alarm system installed at MAP \"K\" pocket with Main FIre alarm control panel - 01 No (14 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower.and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter01 No for one block ) for complete K pocket ) complete. |
| 107 | Comprehensive maintenance of fire fighting system installed at MAP \"G-1\" pocket (4 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) by deploying suitable Technicians. Technician will clean panels, inspect, check the functionality, including replacing of defective parts of Fire Hydrant system having valve, Terrace pump & motor, starters, pressure switch, air pressure tank, panel etc. for satisfactory functioning and carryout physical check by testing once in a month on a convenient day at the discretion ofUser/ Engr-in-Charge in their presence and a report to this extent shall be submitted by the contractor in letter pad and all as directed by Engineer-in-Charge. The technician will grease/ oiling of components, valve, yard hydrant landing valve, hose reel valve etc.Note : The parts to be replaced shall be measured and paid separately. |
| 108 | All as per above item No 60but for Fire fighting system installed at MAP \"G-2\" pocket (18 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete. |
| 109 | Ditto alll as per Ser item No 60 above, but for Fire fighting system installed at MAP \"H\" pocket (10 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete. |
| 110 | Ditto alll as per Ser item No 60 above,but for Fire fighting system installed at MAP \"K\" pocket (14 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete. |
| 111 | Note for Item No 56 to 63 :- (i)The contractor shall submit a maintenance schedule for the entire period of Contract. (ii)The above item will cover round the clock (24 x 7) complaint booking onTelephone Nos to ensure complaints will be attended within 48 Hrs.In case the contractor fails to do so, a penalty of Rs. 250/- per complaint per day for the delayed period will be deducted from payment.(iii)Any breakdown (major or Minor) shall be attended to keep the fire alarm and fire fighting system in working condition.Minor spares i,e. Lubricants, greasing, cloth for cleaning required will be provided by the contractor to make system functional for which cost deemed to be included in the rate (except item No 78 to 126 ).The replacement of any parts (Major) shall be measured and paid under relevant items given from 78 to 126:- |
| 112 | (iv) The qty of MCP, detector, repeater is approx/ tentative. Same may vary atsite. Contractor shall quote his rate accordingly. Nothing extra shall be admissible on this account.(v) Contractor should have MOU with company working in Fire Alarm systembefore quoting of tender and submit copy of MOU document before submitting his tender. If contractor fails to submit MoU with bid, the tender of that contractor will be rejected.(vi)he contractor shall visit the site and check condition of existing system.(viii) The rate quoted includes the cost of making existing defective FIre Alarm system fully functional . The rate of which deemed to be included in the monthly maint quoted rates. Nothing extra shall be admissible on account of this.(vii) The technician will beck functioning of terrace pumps, wetriser/down cummer systems daily or tasks as diected by deptt |
| 113 | Dismantling and Servicing of all multi sensor detector with heat/ smoke combination photoelectric as per exact locations with the help of manufacturer\"s instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and as directed. |
| 114 | S&Fin replacement ofaddressable smoke detectors Addressable type multisensor detector with smoke and heat combination with base with self built intelligenceall as specified and as directed. Note for Item No. 64to 106:- The new item to be fixed shall be completible with existing Fire Alarm & Fire Central System. Contractor shall quote his rate accordingly.Nothing extra shall be admissible on this account. |
| 115 | S&Fin replacement of Indoor addressable heat detectors addressable type with suitable model base with fixed temperature 57 Degree approx complete matching to existing modelFST-851 of NOTIFIER or superior model to match with site all as specified and as directed. |
| 116 | S&Fin replacement of Indoor addressable smoke detectors addressable type photoelectricwith suitable model base,UL listed suitable for Op. Temp 49 degree C complete matching to model FSP-851 of Notifier or other existing model all as specified and as directed. |
| 117 | Supply and fix Addressable intelligent resettable type manual call point model No NFX-MCP-GLASS, EN54-11 TYPE A of NOTIFIER by Honeywell/compatible with existing system, with mounting baseall as specified and as directed |
| 118 | Supply and fix Fault Isolator Module Model No TC811A1006 of make HONEYWELL with mounting backbox completeall as specified and as directed. |
| 119 | Supply and fix Addressable electronic sounder cum Hooter Strobe having Audible and visual alert facility regulated by 24V DC of Model SYS-HSof SYSTEM SENSOR completeall as specified and as directed. |
| 120 | Supply and fix in replacement Addressable fire control module including testing complete all as specified and as directed. |
| 121 | Supply and fix in replacement Addressable fire Relay module including testing complete all as specified and as directed. |
| 122 | Repair of existing Main Fire Control Panel NFS2-640./ Repeater /NCA Network Control Annuciator panel NFS2 3030 of NOTIFIER having remote control, annuciator functions complete incl dismanting and replacing the defective parts and assembling, incl data download/ storage before repair, software upgradation and data uploading and fixing at site for testing complete all as specified and as directed. The rate quoted includes cost of any minor parts not specified here. The major parts shall be measured as under following relevant items |
| 123 | Main CPU Board of Repeater panel |
| 124 | Main CPU Board of Main Fire Control panel |
| 125 | Notifier LCD-160 panel suitable for 640 character display (NCA-2) |
| 126 | Base Card |
| 127 | Notifier Fire Alarm Subassembly S635 card |
| 128 | Loop card |
| 129 | S&Fwall mounted loudspeaker 10 watt 230V AC ,50Hz of sturdy design weather proof type re-entrant horn type loudspeaker for operating under rough conditions complete all as specified and as directed. |
| 130 | M&L for PA Amplifier with built-in Digital Player suitable for multi applicationconfirming to model No SSA-5000DP of Ahuja or equivalent complete. |
| 131 | M&L for Remote Paging Microphone of Make Ahuja Model No APM-201 RM complete all as directed. |
| 132 | M&L for 6 Zone Paging Control unit/ Switcher of Model No APM -202CU of Ahuja Complete all as directed. |
| 133 | S&F maintenance free Lead Acid battery 12 Volt, 7 Ah capacity complete all as specified and as directed. |
| 134 | S&F maintenance free Lead Acid battery 12 Volt, 12 Ah capacity complete all as specified and as directed. |
| 135 | M&L for UPS 650VA/ 360 W with input voltage 220-240V AC, Output 220V- 240V and DC input rating 12V DC, 30 Amp minimum complete. |
| 136 | Supply, laying, installation, testing and commissioning of FRLS PVC insulatedunsheathed copper conductor multistranded copper conductor cable of size 1.5 Sqmm, drawn through existing conduit, laid in trenchescomplete all as specified & directed. |
| 137 | Supply, laying, installation, testing and commissioning of PVC insulated , sheathed copper conductor armoured multistranded copper conductor cable of size 1.5 Sqmm, 2 core drawn through existing conduit, laid in trenches under load/floors, along wellcomplete all as specified & directed. |
| 138 | M&L for DWC (double wall corrugated) HDPE pipe IS 16205 in suitable colour of size 40 mm OD complete all as specified & directed. |
| 139 | M&L for repair to NCA-2 Primary display suitable for Honeywell Notifier panel complete with replacement of all defective parts complete incl taking down old UNSV and testing complete all as directed. |
| 140 | M&L for SMPS AC-DC adaptor suitable for input power supply 140 to 280 volt and out put 24V DC, 5 Amp complete as directed. |
| 141 | M&L for replacement of glass of Manual control point (MCP) complete incl dismantling MCP and refixing after replacement of glass incl connections tightning. |
| 142 | Supply and fix in replacement Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 150mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed. |
| 143 | Supply and fix in replacement Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 100mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed. |
| 144 | Supply and fix in replacement Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 80mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed. |
| 145 | S&F in replacement Cast Iron Butterfly valve having drilled end suitable for 150 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed. |
| 146 | S&F in replacement Cast Iron Butterfly valve having drilled end suitable for 100 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed. |
| 147 | S&F in replacement Cast Iron Butterfly valve having drilled end suitable for 80 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed. |
| 148 | Supply and fix in replacement ball valve of size 50mm dia bore incl all required fittings complete all as specified and as directed. |
| 149 | Supply and fix in replacement ball valve of size 25/20mm dia bore incl all required fittings complete all as specified and as directed. |
| 150 | S&Fin replacement 63 mm dia 15m long CP hose confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and as directed. |
| 151 | S&Fin replacement 20 mm dia 30m long hose reel confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and as directed. |
| 152 | Supply and fix fire hydrant landing valve type A (SINGLE HEAD OUTLET) of 63 mm dia conforming to IS :5290 including rubber or fibre gasket, bolts and nuts complete all as specified and as directed. |
| 153 | S&Fin replacement 63mm dia gun metal branch pipe with instantaneous inlet with threaded type outlet and 15 mm short nozzle conforming to IS 903 complete all as specified and as directed. |
| 154 | Supply & install in replacement Pressure guage 4\" dial 0 - 14 Kgs rating complete all as specified and as directed. |
| 155 | Supply & install Dual Pressure switch Universal type having min Range upto 7.5 Bar and differential scale complete all as specified and as directed. |
| 156 | M & L for removing motor pump assy 15HP, 3 phase, 50 Hz of Terrace Fire pump installed at (G+6) blockby disconnecting electric connections and discharge pipe and trasporting the same to workshop for opening, dismanting and cutting of old burnt winding wire of motor and rewinding ofmotor withcoppper winding wire as per existing size, replacement of Insulation material, oil/ water seal, ball bearing, change of oil seal and making necessary connections with existing copper lead with sleeves from motor to connection plate,cleaning of impeller housing, greasing to all moving parts,bearing and reassembling the motor, Shifting to site back, making joints, electric connection and refitting with the help of tripod/any other machinery such as hydra, connecting, commissioning and testing on full load complete including replacement of worn out nut bolts or any minor parts required to make motor pump assy serviceable all as specified and as directed by Engineer - in - charge. |
| 157 | Supply and fixin replacement cold shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 150 to 240 sqmm 3.5 core complete all as specified and as directed. |
| 158 | Taking down/ out unserviceable UG cables of any cross sectional area, any type, any make from trench/ from wall/pole/fixed with walls/ incl pulling through pipe by opening connections and joints including removing pipe, carefully getting out bricks etc keeping aside for re-use complete all as specified and directed.Note : Earthwork shall be measured and paid under relevant items of BOQ. |
| 159 | Supplying, laying, jointing and testing 1100 volts grade XLPE insulated, PVC sheathed (heavy duty) electric strip/ wire armoured electric cable of size 240 Sqmm 3.5 core with stranded aluminium conductor, laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and directed. |
| 160 | Ditto all as per Ser item No 110 above,but of size 95 sqmm 3.5 core. |
| 161 | Ditto all as per Ser item No 110 above, but of size 50 sqmm 3.5 core. |
| 162 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and gettingout complete all as specifiedand directed by Engineer-in-Charge. |
| 163 | Returning, filling in,soft/loose soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge. |
| 164 | Removal of surplus soft/loose soil soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point completeall as specified and directed by Engr-in-charge. |
| 165 | M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches, punned down to thickness of 18cm complete all as specified.Note: punned down thickness of 18cm shall be measured for payment. |
| 166 | Supply & laying old size sub class \"B\" bricks laid flat in trenches over the cable with the length of brickperpendicular to the directionof cable length, adjacent/abutting each othercomplete all as specified and directed by Engineer-in-charge. |
| 167 | Taking down LT cable of any size frompole/ panel or any location by opening cable connections and cleaning the cable bycleaning tissue, gel and S&Fwith gland to panel and restore the power supply complete all as specified and directed. |
| 168 | Supply, fix and jointing heavy grade MS ERW pipe 80 mm bore heavy grade, laid in trenches / under floors or fixed to wallincluding all fittings, such as coupling, bends, elbow, and tee etc, with welded joint all as specifiedand as directed. |
| 169 | M&L for Boring hole under the road/ pavement/ hard standingand inserting HDPE pipe of 100mm at a depth not less than one metre below ground level complete all as specified & directed. Note: The quoted rate includes cost of HDPE pipe 100mm pipe min. |
| 170 | M& L for Cutting chases in road/ hardstanding upto depth of 150 mm min holes in or through walls /earth surfacefor in and including inserting GI/HDPE Pipe up to 100mm bore mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. (Note: The quoted rate includes GI/HDPE pipe.) |
| 171 | S&Fin replacement 3 pole contactors 12 Amps with coil voltage 240 Volts, 2NO + 2NC, model MO-12 of L&T or equivalent in Havells/C&S/BCH/Indo Asian/L&T/ Siemens/Schneider |
| 172 | M&L for thermal overload relay, 3 pole, range 8.5 to 12.5 A, with NO + NC contacts confirming to model RTO-1 |
| 173 | S&Fin replacement MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer including dismantling/ taking down existing MS work complete all as specified and as directed.Note: Unexposed surface shall be given one coat of primer only. |
| 174 | M & L Cutting/removing of bushes/small trees/vegetationgrowth upto a distance of appx 20 mtr around the LT panel,DG sets etcnot exc 30cms deep incl drains all around the plant incl rough surface leveling/cutting,filling upto 12\" height/ depth all around the plant and burning at a distance of 50mtr (minimum) in the presence of Engr-in-charge including sprinkling the round up chemicals for drying/killing the bushes,shrubs etc. |
| 175 | M & L for factory made machine pressed precast concrete interlocking paver block any shape and size cofirming to IS 15658-2006 of 60mm thickness M35 grade with grey cemment and no pigments interstices and jointed over and inclcluded 25 mm thick dry sand bedding as in floors cushioning layer below interlocking paver blocks( 50 % grey & 50 % red) including watering and as specified over 100mm thick PCC 1:4:8 & over 100mm thick hardcore complete all as specified & directed. Excavation, removal of surplus material,sanding and PCC cost is deemed to be included in quoted rate |
| 176 | S & F in Replacement of Front operated on load change over switch, 250 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 177 | S & F in Replacement of Front operated on load change over switch, 400 Amps capacity, suitable for 3 phase, 4 pole, 415 Volts,front handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one, complete all as specified and directed by Engr-in-Charge. |
| 178 | S&F in replacement offload change over switch 400 Amps 4 pole 415 Volts with sheet steel enclouser including Making connections of both input and output cables end termination in changover complete all as specified and directed by engineer in charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail