| Sl. No. | Item Description |
| 1 | Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120,Litres including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed .Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above. |
| 2 | S & F in replacement over load protector relay suitable for 40 to 150 litrs Litres capacity water coolerscomplete all as specified and as directed . |
| 3 | S & F in replacement Starting relaysuitable for 40/80, 60/120, 150/150 Litrecomplete all as specified and as directed . |
| 4 | S & F in replacement thermostat suitable for 40/80/120/150 Litre capacity water coolers. |
| 5 | S & F in replacement condenser motor fan blade suitable for 40/80/120/150 Litre capacity water coolers complete all as specified and as directed . |
| 6 | Disconnecting the electric mains and taking out unserviceable condenser fan motor 1/32hp to 1/16 HP as per site requirmentfrom water cooler cap.40/80,60/120, 150/150 Litre and supply and fixing with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as specified & as directed. |
| 7 | S & F in replacement Starting Capacitor 25 MFD complete all as specified and as directed . |
| 8 | S & F in replacement running Capacitor 10 MFD complete all as specified and as directed . |
| 9 | S & F in replacement waste water tray complete suitable for 40/80, 60/120, 150/150 Litre capacity water coolers complete all as specified and as directed . ( Suitable for Voltas/Sidwal/Blue Star make water coolers). |
| 10 | S & F in replacement chromium plated push taps suitable for 40/80/120/150 Litre capacity water coolers all as directed. |
| 11 | M&L for Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed. |
| 12 | M&L for waste water adaptor PVC, 32mm size suitable for water cooler of any capacity fixed as in repair complete all as specified and directed. |
| 13 | S&F of PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed as in repair complete all as specified and directed. |
| 14 | Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. |
| 15 | Dismantling and removing defective compressor and supply and fixing in repairs new sealed compressor of approved make obtained from authorised dealers commissioning and testing Water Coolers of 40/80 ,60/120/150/150Litres capacity complete all as specified and as directed. |
| 16 | Disconnecting the mains and taking out the unserviceable condenser coil and supply & fixing new condenser coil as per existing size & patterns for Water Coolers of capacity40/80 , 60/120, 150/150 Litres complete all as specified & as directed. |
| 17 | M&L for taking down desert cooler of any type/size/model from any height / floor for servicing like changing of wood wool pads, kit motor, submersible pump, fan blade, front grill, wiring, capacitor, cleaning or any other repair work,greasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washersas specified and re-fixing to existing place after repair work/overhauling complete all as specified and directed.Note :- (i) The rates quoted by the contractor shall deemed to include the cost of T&P.(ii)The items required to be replaced shall be measured and paid separately under relevant items. |
| 18 | Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers i.e. side panel, bracket, body & desert cooler stand with two coats of synthetic enamelled paint (1st grade quality) including two coats of black water proof paint on reserve water tankcomplete all as specified & as directed. |
| 19 | Providing and fixing protective shed over outdoor units of Split ACs to safeguard from direct sunlight and rain, fabricated with 0.5 mm thick GI sheet (corrugated/plain or powder coated) fixed over MS angle framework , installed with proper slope for rainwater drainage, ensuring minimum 300 mm side clearance and 450 mm vertical clearance for ventilation, complete with cutting, welding, anchor fasteners, and two coats of enamel paint over red oxide primer complete all as specified & as directed. |
| 20 | S & F in replacement wood wool padof suitable size for 24” sweep desert cooler, 01 Set comprising of 3 Nos of pads approximate weight 500-600 Gmsas per sample complete all as specified & as directed. |
| 21 | S & F in replacement wire mesh for desert cooler pad (Set of Three) including taking down old one. complete all as specified & as directed. |
| 22 | S & F in replacement submersible pump 230 Volts,1/15 HP to 1/40 hp (as per site requirment) single phase, AC suitable for Plastic body/Steel body Desert cooler. complete all as specified & as directed. |
| 23 | S & F in replacement PVC pipe for connecting pump and water distributor of size 15 mm dia including PVC elbow,.complete all as specified & as directed. |
| 24 | S & F in replacementPVC elbow for desert cooler of suitable size .complete all as specified & as directed. |
| 25 | S & F in replacement PVC 4 Way distribution cross for desert cooler complete all as specified & as directed. |
| 26 | S & F in replacement running capacitor of 4/6 MFD capacity for desert cooler complete all as specified & as directed. |
| 27 | M&L for Aluminium heavy duty Fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed. |
| 28 | M&L for PVC heavy duty Fan blade with bush for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed. |
| 29 | M&L for cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed. |
| 30 | Supply and fixing in repairs ofdesert cooler kit fan motor, single speed, 230 V, 50 Hz of capacity 90 Watt 1450 RPM, copper wounded including nuts bolts for fixing complete all as specified and as directed. |
| 31 | Supply and fixing Desert cooler exhaust fan motor, single speed, 230 V, 50 Hz of capacity 150 Watt 1400 RPM, copper wounded including nuts bolts for fixing including taking down old unserviceable one complete all as specified and as directed. |
| 32 | S&F of 15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed. |
| 33 | M&L for Plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed. |
| 34 | M&L for switch piano type, 240 volts, Singe Pole, one ways, 5/6 Amps, ISI Marked, fixed in desert coolers including taking down old unserviceable complete all as specified and directed. |
| 35 | M&L for selector switches three way, 230 volts single phase of standard quality fixed in desert coolers fixed in repair complete all as specified and directed. |
| 36 | M&L for 1.50 sqmm, PVC insulated and sheathed round flexible three core copper conductor cable including necessary connection fixed in desert coolers complete all as specified and directed. |
| 37 | M&L for front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet of approved make suitable for fixing 5 Amp switch, three speed regulator and indicating lamp. suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed. |
| 38 | S&F of side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed as in repair complete all as specified and directed. |
| 39 | S&F of Mild Steel Sheet body of 22 gauge suitable for coolers of capacity 4000/5000 Cum/hour including taking down old unserviceable complete all as specified and directed. |
| 40 | Supply and fixing in replacement Gl powder coated perforated type cable tray 14 SWG, (2mm thick) of width 150mm and height 50mm with necessary coupler plate and cable tray cover where required with PVC tie for fixing of cable compete all as specified and directed. |
| 41 | S&F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) of sheet 20 Gauge andwith side panels (03 Nos) fabricated out of 22 SWG PGI Sheet along with PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e., side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with \" GE(AF) JAISALMER (MES)\" letter size of 50mm height in stencil in black/white complete all as specified & as directed. |
| 42 | S&F for wall mounted remote control holder/stand for Split/Windowtype Air-conditioner units, moulded from high-quality ABS/Polycarbonate plastic, of approved design and finish, suitable to accommodate standard AC remote controllers. The work shall include supply of holder, drilling holes in wall, fixing with stainless steel screws and nylon/rawl plugs, making good disturbed surface, and handing over in neat functional condition complete all as specified and as directed. |
| 43 | M&L formaking one number hole of upto 20” (Twenty Inches) length and 2” (Two Inches) diameter in existing wall/slab (RCC/brick/stone) by means of core cutting machine, including proper fixing of machine, T&P, labour, scaffolding as required, ensuring neat and clean finish without damage to adjoining surface, and after completion of work, properly filling the annular gap around the pipe/opening with cement mortar (1:2) or white cement as required, finishing the surface flush with adjacent area, cleaning the site of all debris and making good the surface, all complete as per specification and as directed by Engineer-in-Charge. |
| 44 | M&L forthepainting workfor AC outdoor unit stand /shade exposed to direct sunlight, including surface preparation (mechanical scrubbing and rust removal), applying one coat of anti-corrosive primer (conforming to IS standards), followed by two coats of weather-resistant enamel paint in the specified color as per the directions, ensuring smooth and uniform finish, proper material labeling, and adherence to color codes for uniformity and aesthetic appearance omplete all as specified and directed. |
| 45 | M & L for surface restoration work at locations where split or window AC units were previously installed, including filling existing holes made for pipes, cables, drainage, or mounting brackets with appropriate cement mortar. also including rectifying any damage caused during the installation or removal of the units, ensuring a smooth and uniform surface finish, and restoring the area to its original condition as per the instructions of the engineer-in-charge |
| 46 | M &L for detecting the leakage of gas ofWater coolers at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 47 | Supply and filling refrigerant gas R-134A/R32/R410/R600/R-410C in Refrigerators/ Deep freezers/ Water coolers of any capacity, model and make complete all as specified and directed by engineer in charge. |
| 48 | Taking downfor servicingof split type AC 1.5/2 TR Capacity of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building and including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution and reassembling of complete unit insatisfactory working condition after necessary servicingas required and refaxing the same in existing position ,and including testing for smooth functioning complete all specified and as directed . |
| 49 | All as per srl item No 48.00 here-in-before but window type AC ofcapacity 1.5/ 2 TR complete all as specified and as directed. |
| 50 | Material & Labour for rectifying electrical wiring fault of any type of wiring (concealed/surface/casing-capping/conduit/outdoor /indoor of split ac) capacity type AC and make them functional and also carry out the required repair work as per site requirement and make good the disturbed surfaceas directed by engineer in charge. |
| 51 | M&L for running capacitor, 55+6 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 52 | M&L for running capacitor, 45+4 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 53 | M&L for starting capacitor 2.50 MFD suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed. |
| 54 | M&L for starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity of any type or make fixed as in repair complete all as specified and directed. |
| 55 | M&L for thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed as in repair complete all as specified and directed. |
| 56 | S & F Over load relay 3 Pole, 5 to 16 Amps suitable for split/window type Air Conditioner upto 2.0 TR fixed as in repair complete all as specified and directed. |
| 57 | S & F in replacement Condenser fan blade for split type AC/Window type A.C ofany Capacity complete all as specified and as directed ..(Make as per site requirement.) |
| 58 | M&L for circuit kit of window type Air Conditioner complete with lugs, thimble and selector switch fixed as in repair complete all as specified and directed. |
| 59 | S & F in replacement remote control of existing make including battery for split/window /tower AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as specified & as directed |
| 60 | M & L forCarryout the repairing work in remote control of AC of any type and any capacity complete all as specified and directed to be included in above quoted rates. |
| 61 | Supply & fixingin repair/replacement of indoor/OutdoorPCBsuitable for inverter type split type AC of 1.5 toncapacity and model complete all as specified and as directed. |
| 62 | Supply & fixing in repairs plastic louvers for (Front panel)for Window AC 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 63 | Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8\"\"), 6mm (1/4\"\") and 12mm (1/2\"\")for Split AC /Window AC 1.5/2 TR capacity complete all as specified & as directed. {Note:-(i) 15mm (5/8\"\") or 6mm (1/4\"\") and 12mm (1/2\"\") made one set(ii) Supply & filling of refrigerant gasshall be measured and paid under relevant item.} |
| 64 | Supply & fixing in repairs of capillary tube for Split/ Windowtype AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 65 | Supply & fixing in repairs of capillary filter for Split/ Windowtype AC of capacity 1.5/2 TR complete all as specified & as directed (Make as per Sample). |
| 66 | Shifting, installation, and re-commissioning of Split Air Conditioner (1.5/2.0 TR) from one location to another by completely dismantling the existing unit without any damage, shifting it to the new site, and reinstalling it, including gas charging to the required level, the work includes drilling holes into brick walls for connecting indoor and outdoor unit pipes, cutting chases for concealed conduit wiring and water tubing, and making good the surfaces with cement mortar (1:3) at ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc., as required. Additionally, connecting indoor and outdoor units with copper pipes, installing drainage pipes, fixing the outdoor unit on a separately provided stand, carrying out temperature and gas pressure testing, and complete installation and commissioning are part of the scope. Necessary carpentry, plumbing, masonry work, and white cementing are also included complete all as specified and directed.. Note: Drain pipe, copper pipes of required size, refrigerant gas, outdoor stand, power plug, MCB, and copper wire will be paid under the relevant item. |
| 67 | Shifting, installation, and re-commissioning of Window Type Air Conditioner (1.5 / 2.0 TR) from one location to another by carefully dismantling the existing unit without any damage, shifting it to the new location, and reinstalling the same complete in all respects.The work includes making necessary adjusting or modifying the window opening as necessary, and ensuring proper alignment andsupport (if required) for the unit at the new location, such as cutting, resizing, and height adjustment of the window opening to suit the dimensions of the Window AC. Covering the remaining open portion of the window with suitable thickness plywood / board, properly fixed and finished, including sealing gaps to make the installation airtight and aesthetically acceptable also includes necessary carpentry, fabrication (if required), masonry work, cutting and making good of walls/window frames, proper alignment, leveling, vibration-free mounting of the AC unit, connecting drain outlet, testing for cooling performance and complete installation and commissioning.All works shall be carried outto the satisfaction of the Engineer-in-Charge, complete as specified and directed.Note:-Drain pipe, electrical cable, plug top, MCB, and any other consumables required for window modification shall be paid under the relevant item |
| 68 | Taking down unserviceable outdoor unitof split type AC of any capacity as directed by engineer in charge. |
| 69 | Disconnecting from mains and taking out existing unserviceable resive sealed compressor unit and supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 1.5 TR window type AC/ Split AC of existingcapacity and makecomplete includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc and commissioning complete all as specified & as directed. |
| 70 | Supply and fixing in repairs 1.5 TR capacity window type AC kit (without compressor)including condenser coil & evaporator coil (copper), copper wounded blower motor, cooling coil, front grill blower motor, chassis, base plate, reverse valve, capacitors and copper pipes & PVC wires of suitable size for internal connection etc including taking down old one complete all as specified and as directed . |
| 71 | Supply and fixing 1.5 TR capacity split type Air Conditioner outdoor kit with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor coveringwithout compressor, suction and discharge valve, capillary tube of expansion valve,contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed. |
| 72 | Disconnecting from mains and taking out existing unserviceable resive sealed compressor unitand supply & fixing in replacement sealed compressor unit with latest refrigerant gas compatible, suitable for 2 TR window type AC/ Split AC of existingcapacity and makecomplete includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc and commissioning complete all as specified & as directed. |
| 73 | Supply and fixing 2 TR capacity split type Air Conditioner outdoor kit with latest refrigerant gas compatible including condenser coil with protection fins, blower motor and its fan blade, chassis & base plate with outdoor coveringwithout compressor, suction and discharge valve, capillary tube of expansion valve,contactor with PCB card, capacitors and copper pipes & PVC wires of suitable size for internal connection, etc. complete all as specified & as directed. |
| 74 | Taking down unserviceable indoor unitof split type AC of capacity any TR with remote complete all as specified & as directed. |
| 75 | Supply & fixing new indoor unit with remote control and with latest refrigerant gas compatible complete set suitable for 1.5 TRcapacity complete all as specified & as directed. (Note for :- Outdoor and indoor unit of AC shall be compatible either with each other orexisting units) |
| 76 | Supply & fixing new indoor unit with remote control and with latest refrigerant gas compatible complete set suitable for 2 TRcapacity complete all as specified & as directed.(Note for :- Outdoor and indoor unit of AC shall be compatible either with each other orexisting units) |
| 77 | Supply & fixing in replacement wall mounted digital Voltage Stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 150V - 285 V with output voltage stabilized at 230V with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and as directed. Make: V-Guard model No-VND 500 or equivalent model of Bluebird, Emerson or any other Make mentioned in PS. |
| 78 | Taking down unserviceable indoor unitof inverter split type AC of capacity 1.5 TR andsupply & fixing new inverter type indoor unit complete set suitable for 1.5 TRcapacity complete all as specified & as directed.(Make as per existing on site ) |
| 79 | Supply and fixing in repairs 1.5 TR capacity inverter type split type Air Conditioner outdoor kit including condenser coil, blower motor, chassis, base plate , suction and discharge valve, contactor, capacitors and copper pipe, PVC wires, PCB compatible to indoor unit, of suitable size for internal connection, etc. including taking down old unserviceable one complete all as specified & as directed. (Make as per existing on site ) |
| 80 | Supply & fixing in replacement of Split / Window A/C air blower motor copper wounded for 1.5 TR & 2 TR capacity AC complete all as specified & as directed..(Make as per site requirement.) |
| 81 | Supply & fixing in replacement of copper wounded motor for outdoor of Split type AC of 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make as per site requirement.) |
| 82 | M & L for Disconnecting the mains and taking out the unserviceable condenser coilofspilt type/ window type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 83 | M & L for Disconnecting the mains and taking out the unserviceable evaporator/cooling coilof window/Split type AC of capacity 1.5/ 2TR of any make from any location and Carryout the pressure test of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 84 | M&L in repair of complete condenser unit (outdoor unit) 1.5TR including taking down old unsvcomplete all as specified and directed. |
| 85 | M&L in repairin replacement of complete evaporator unit (indoor unit) 1.5TR including taking down old unsvcomplete all as specified and directed. |
| 86 | Taking down unserviceable insulation for copper pipe, supply and fixing new nityrile rubberinsulation for copper pipes suitable for Split AC of capacity from 1.5 to 4.0 TR complete all as specified & as directed. |
| 87 | Supply & fixing in replacement heavy duty copper pipe 12mm (1/2\") dia/ bore complete including brazing, welding, nuts,bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. |
| 88 | ditto- all as per item No. 87 above but copper pipe 6mm (1/4\") dia/ bore. |
| 89 | ditto- all as per item No. 87 above but copper pipe 15mm (5/8\") dia/ bore. |
| 90 | ditto- all as per item No. 87 above but copper pipe 10mm (3/8\") dia/ bore. |
| 91 | Taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia with coupler Joint for Split/window AC complete all as specified & as directed. |
| 92 | M & L forCarryout the pressure test with nitrogen gas of refrigeration system, detecting leakage including soldering and brazing of leaking copper tubing complete all as specified and directed. |
| 93 | M & L for complete topping up the refrigerant gas( R22) in split/window type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 94 | M & L for complete topping up the refrigerant gas( R22) in split/window type 2.0 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 95 | M & L for complete topping up the refrigerant gas( R32/ R410A/R407) in split/window AC type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 96 | M & L for complete topping up the refrigerant gas(R32/ R410A/R407) in split/window AC type 2.00 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. |
| 97 | Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for window/ Split AC 1.5 to 2.0 TR complete all as specified & as directed. |
| 98 | Taking down unserviceable contactor and supply and fixing new contactor ( MNX 12/ MNX 18) suitable for Tower / Cassette AC up to 2.5 TR capacity complete all as specified & as directed. |
| 99 | Dismantling the existing broken blower fan blade of the indoor units of the split type AC of Capacity 1.5/2 TR and supply and fixing in repairs new blower fan blade complete all as specified and directed. |
| 100 | M&L for swing motor suitable for split air conditioner of capacity 1.5/2.0 TR invertor and non invertor type fixed as in repair including taking down old unsv complete all as specified and directed. |
| 101 | Supply & fixing in replacement Outdoor Unit (ODU) Stand for 1.5TR/ 2 TR Type split AC complete all as specified & as directed. |
| 102 | Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing capping(heavy grade) of adequate size with all fittings and casing capping /conduit accessories of surface type including one run 4 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unserviceable sub main wiring complete all as specified and as directed. |
| 103 | M&L for wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS four core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed. |
| 104 | Supply and fixing in repairs of metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps including taking down old unserviceable metal clad socket complete all as specified and as directed. |
| 105 | Supply and fixing in repairs of MCB SP 240 volts 6 to 32 Amps, 10 kA, \"C\" curve complete all as specified and as directed. |
| 106 | Supply & fixing in repair metal clad socket of 20 Amps complete all as specified & as directed. |
| 107 | Supply & fixing in repairs metal clad plug with two pin of capacity 20 Ampscomplete all as specified & as directed. |
| 108 | M&L for Power plug top, ISI Marked including taking down old unserviceable complete all as specified and directed. |
| 109 | Supply & fixing in repair/replacementPCB, suitable for non-inverter type, split type AC/ window type AC of any capacity and model complete all as specified and as directed. |
| 110 | Supply & fixingin repair/replacement of indoor & Outdoor PCBsuitable for inverter type split type AC of 1.5 toncapacity and model complete all as specified and as directed. |
| 111 | Supply & fixingin repair/replacement of indoorPCB for indoor suitable for inverter type split type AC of 2 Ton capacity and model complete all as specified and as directed. |
| 112 | Supply & fixingin repair/replacement of OutdoorPCB forfor inverter type split type AC of 2 Ton capacity and model complete all as specified and as directed. |
| 113 | Attending complaints of Air-conditioning ,desert coolers & water coolersas and when required / call up by this office for non-functioning or under-performing equipment such as Split AC, Window AC, Desert Coolers, Refrigerators, Deep Freezers, Water Coolers, etc. The work shall include:- 1. Diagnosis / detection of defects in complete system including compressor, condenser, evaporator, blower fan, motors, PCB cards, thermostats, overload relays, sensors, selector switches, contactors, wiring, drain piping, refrigerant leakages, air filters, etc.2.Carrying out minor repairs such as tightening of connections, rectification of minor electrical faults & checkingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, adjustment of controls,oiling/greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc. making the installation functional.3. Major defective parts/components, if required to be replaced, shall be measured and paid separately under respective schedule item(i) Minor repairs shall be carried out on spot and are deemed included in this item.(ii) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items as S & F in replacement and Labour charges for taking out old spares .(iii) Adequate skilled tradesmen/technicians with supporting manpower shall be deployed by contractor. They shall remain present on all working days including Saturdays and holidays from 0930 hrs to 1800 hrs. Detailed complaint shall beissued by the concerned JE every morning duly signed after rectification.(iv) Complaints received before 1300 hrs shall be attended on same day. Complaints received after 1400 hrs shall be attended next working day before 1300 hrs.(v) Non-attendance of complaints as per schedule shall invite penalty of Rs. 500/- per complaint per day.(vi) Any delay in completion shall immediately be intimated to AGE/JE concerned. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail