| 1 | M&L for surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches n exc1.5 m wide and n exc 1.5 m indepth; for foundation, etc. orfor shafts, wells, cesspits,manholes, pier holes, etc. area nexc 10 sq m on plan complete all as specified and directed. |
| 3 | Returning, filling inincluding spreading leveling watering and well ramming in layers n exc 25 cm thick all as specifiedand directed by Engineer-in-Charge. |
| 4 | Earth filling under floor, including spreading, leveling, watering and well rammingin layers n.exc 25 cm in soft/loose soilcomplete all as specified and directed. Note - Excavated earth shall be used for refilling under floor. |
| 5 | Removing excavated material to a distance exc 1.5but n exc 5.0 Kmand depositing where directed above starting point complete all as specified and directed by the Engineer -in-charge. |
| 6 | M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as specified and directed. |
| 7 | M&L for reinforcement cement concrete (Design Mix) M-25(using 20 mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-rammed piles and mass concrete complete all as specified and directed. |
| 8 | M&L for reinforcement cement concrete (Design Mix) M-25 (using 20 mm graded aggregate) as in columns,pillars, piers, posts & struts complete all as spd & directed. |
| 9 | M&L for reinforcementcement concrete (Design Mix) M-25 (using 20 mm graded aggregate) as in slabs , roof projections etccomplete all as specified and directed. |
| 10 | M&L for reinforcement cement concrete (Design Mix) M-25 (using 20mm graded aggregate) as in roof beams, cantilevers bressummers, lintels over 1.5m span complete all as specified and directed. |
| 11 | M&L for reinforcement cement concrete (Design Mix) M-25 (using 20mm graded aggregate) as in chajjas complete all as specified and directed. |
| 12 | M&L for TMT bars 10 mm dia and over cut to length, bent to shape as required incl cranking bending hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia for lintel, column,footing and any other structural member complete all as specified and as directed. |
| 13 | M&L TMT Bars8 mm dia, cut to length, bent to shape as required including cranking, bending, hooking ends and binding with MS Wire (annealed) not less than 0.9 mm dia, as in stirrups for column, plinth beam, beam and lilten spaces and binders complete all as specified and as directed. |
| 14 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as spd and directed. |
| 15 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beam and similar work as in flat surfacecomplete all as specified and directed. |
| 16 | Formwork to sides and soffits of floor or roof beams,beam haunching,girders,bresummers,lintels,cantilevers,shelves including supports,overhangs etc also spays between floors and beams as in flat surface complete all as specified and directed |
| 17 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions as in flat surface complete all as specified and directed. |
| 18 | Formwork to chullah hoods, chajjas, troughs and similar items including edges as in flat surface complete all as specified and directed. |
| 19 | M&L for ATT as treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 20 | M&L for ATT for flooring as treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 21 | M&L for ATT as treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface areacomplete all as specified and directed. |
| 22 | M&L for ATT as treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as spd & directed. |
| 23 | M&L for 75 mm thick cement concrete type D-2, 1:4:8 (40 mm graded aggregate) as in sub base of flooring etc complete all as specified and as directed. |
| 24 | M&L for 25 mm thick cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in flooring etc complete all as specified and as directed. |
| 25 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed compelet all as specified and directed |
| 26 | M & L for brick work with sub class \"B\" bricks, oldsizes , straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as spd and as directed. |
| 27 | M&L brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed. |
| 28 | M&L for rendering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4 with integral water proofing compound finished even and smooth without using extra cement complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately. |
| 29 | M&L for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. |
| 30 | M&L for plastering 5 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed. |
| 31 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 32 | M&L for non skid ceramic colouredtilesof 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors set and jointed and filled with epoxy and pointed in white or coloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement & sand mortar 1:6complete all as specified and as directed. |
| 33 | M&L for coloured glazed ceramic tiles 600 x 300 x 8-9 mm thickon vertical surfaces such as skirting/dados etc,set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles overand including rendering 10 mm thick in CM 1:4 on wallcomplete all as specified and directed. |
| 34 | M&L for apply acrlic based waterproofing flexible liquid applied single component, weather resistant acrylic water proofing membrane for all types of exposed roof slabs (new and old) terraces (slopped and flat) etc ultra voilet rays and heat reflecting system Complete all as specified and directed |
| 35 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window /Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 of 100 gms) fabricate with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (face) & 1100 N (Edge) minimum compressive strength of 58 N/mm², modules of elasticity 900 N/mm² and resistance to spread of flame of Class A category with property and fire retardant fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia & length complete all as specified and directed |
| 36 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window /Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 of 100 gms) fabricate with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (face) & 1100 N (Edge) minimum compressive strength of 58 N/mm², modules of elasticity 900 N/mm² and resistance to spread of flame of Class A category with property and fire retardant fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia & length complete all as specified and directed |
| 37 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 38 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 39 | S&F100 mm long SS butt hinges medium weight, complete all as specified and directed . |
| 40 | S&F SS 150 mm long barrel tower bolts of extruded section & fixed complete all as specified and directed. |
| 41 | S&F SS 150 mm sizehandles cast type anodized complete all as specifed and directed |
| 42 | S & F 250 mm long SS, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed. |
| 43 | S&F vitreous china pedestal pattern type wash down water closet pan white with EWC seat cover and floor mounted fittings etc of Make Parryware \"Niagra\" Cat Pt No - C0252+E8094 complete all as per the manufacturers instruction or as directed by the Eng-in-Charge |
| 44 | S&F CP Hand shower (Health Faucet) (ABS Body ) with 8 mm dia 1.00 Mtr long flexible tube & wall Hook with N.R.V (Back Flow Preventer) (Make - Jaquar model No ALD-CHR-579) |
| 45 | S&F Vitreous China Ware Wash hand basin oval type white, of (550 x 445) mm size, with 32 mm dia stainless steel waste coupling of Make Jaquar (Cat Pt No ALD-705L130) & CI brackets including cutting for and pinning ends of brackets or erecting stand complete of Make Parryware \"Cascade NXT\" Cat Part No C0407 |
| 46 | S&FVitreous China Urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) incl S&Furinal spreader of CP for fixing with 15 mm dia pipe.(Minimum weight 60 gms). Complete all as spd and directed. |
| 47 | S&F PVC body valve less syphonic action type flushing cistern white low level with inlet ball valve float and handle including brackets 10 lits capacity fixed in repairs. (Make : Parryware Slimline standard Code No C8297) |
| 48 | S&F Mirror 600 x 450 mm, beveled Edge, Selected quality Glass, mounted on 6 mm thick AC Building Board or Commercial Plywood and fixed to Wooden Plugs with Chromium plated Brass Screws and Cup Washers and fixed-in-repairs complete all as specified and as directed. |
| 49 | S&F Brass Chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges, complete all as specified and as directed. |
| 50 | S&FCP soap dish with glass finish (Glossy) complete all as specified and directed. |
| 51 | S & F fancy type angle stop cock, 15 mm dia, cast copper alloy, with chromium plated, screwed down , high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed quarter turn with water saving nozzle”, complete all as specified and as directed. |
| 52 | S & Ffancy type pillar tap 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"hot\" or \"cold\"with long screwed shanks and fly nuts, screwed for iron pipe and fixed quarter turn with water saving nozzle”, complete all as specified and as directed. |
| 53 | S&F 15 mm fancy type CP Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 54 | S&F PVC connections 15 mm size of PTMT of 600 mm long complete all as specified and directed. |
| 55 | S & F flexible (coil shaped) PVC waste pipe for wash basin and urinal (as required dia) with length not less than 700 mm connected to PVC waste fittings complete all as specified and as directed. |
| 56 | S&F PVC (SWR) 75 mm bore floor trapplain with grating including joints with solvent cement complete all as specified and directed. |
| 57 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints and jointed with adhesive and laid in floors/ trenches/walls (110 mm bore) etc complete all as specification |
| 58 | S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints and jointed with adhesive and laid in floors/ trenches/walls (75 mm bore) etc complete all as specification |
| 59 | S&F 110 mm bore PVC (SWR) bends and fixed in position with adhesive complete all as specified and directed |
| 60 | S&F, 75 mm bore PVC (SWR) bends and fixed in position with adhesive complete all as specified and directed |
| 61 | S&F PVC (SWR) vent cowl of 75 mm bore complete all as specified and directed. |
| 62 | S&F Salt-glazed stoneware gully traps square or round mouthed for \"P\" or \"S\" trap etc complete all as specified and directed. |
| 63 | S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed. |
| 64 | S&F stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore pipe complete all as specified and directed. |
| 65 | S&F stack clamps out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore pipe complete all as specified and directed. |
| 66 | S&F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors concealed type. (cutting and chasing is included in the rates) |
| 67 | S&F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors concealed type. (cutting and chasing is included in the rates) |
| 68 | S&F 25 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc. fixed to walls & ceilings or laid in floors. (cutting &chasing is incl in the rates) |
| 69 | S&Frotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top),double layer construction, ISI marked, hoisted & fixed in position including over flow 450mm, waste pipe 600mm long with all fittings such as dead plugs and check nutsetc. of 20 mm dia complete all as specified and as directed. |
| 70 | S&F ball / float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20 mm bore (minimum weight 210 gms) complete all as specified and as directed. |
| 71 | S & F Gun-metal, globe or gate valve, 25 mm dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 72 | M&L for hardcore of broken stoneboulder of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 73 | M&L for 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in plinth protection etc complete all as specified and directed. |
| 74 | M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer over 2 mm wall care putty complete all as specified and as directed. |
| 75 | Preparation of newly plastered surfaces on ceilings and applying two coats of white wash complete all as specified and as directed. |
| 76 | M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior weather paint over one coat of primer complete all as spd and as directed. |
| 77 | S & F including fabricating of aluminium powder coated having minimum thickness of powder coating 50 micron for door / window / ventilator frame, shutters and partition including necessary joining cleats, glazing clips, aluminium snap beading having minimum wt 100gm/RM, rubber neoprene gasket, screws, dash fasteners, rawel plug for fixing of screw in wall or floor etc. aluminium sections as approved by GE complete all as specified and directed. |
| 78 | Supply and fixing frosted Sheet Glass4.0 mm thick, Square or Rectagular, area not exc. 0.50 Sqm in Each Pane and fixing to Aluminium Window, Ventilator Shutters, complete all as specified and as directed. |
| 79 | Removing excavated material exc. 250 mtr but not exc. 500 mtr and depositing where directedcomplete all as specified and directed. |
| 80 | Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 81 | M&L forheavy duty vitrified parking tiles of size 300 x 300 x 15 mm thick fixed over and including 15 mm thick screed bed in cement mortar 1:4 fixed using spacers of 5-6 mm and joints filled with epoxy etc for path/hardstanding of any type and pattern complete all as specified and directed. |
| 82 | M&L for old size brick work with sub class B bricks straight or curved on plan exc 6 m mean radius built in cm 1:4. complete all as specified and directed. |
| 83 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed. |
| 84 | M&L for precast cement concrete type B1, 1:2:4 (20 mm graded stone aggregates) set in CM 1:4 as in cover slab for manholes etc complete all as specified and directed. |
| 85 | M&L concrete bed to drain pipes including packing under and haunching against the sides of pipes afte they are laid and tested cement concrete 1:3:6 type C2, for 150 mm dia pipe. |
| 86 | S& F 150 mm bore reinforced concrete pipes class NP-2 laid in trenches and jointed complete with collars as directed by Engineer in charge. |
| 87 | Cutting into existing manhole for connecting new drains making good to pipe of dia 150 mm and rendering and cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) incement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified andas directed. |
| 88 | Demoliton of cemet Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 89 | M & L for rendering 10 mm thick on other than fair faces of brick wall finished even and smooth without using extra cement in CM 1:6 incl preparation of newly plastered surface of wall including providing and applying plaster of paris puttyof 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two coat of distemper oil emusion complete all as specified and directed. |
| 90 | M&L for glazed ceramic coloured tiles450 x 350 x 7-8 mm thick in skirting/dado or vertical surface set andjointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering on fair faces of brick work or concrete surface in cement moratar 1:4 complete all as specified and directed. |
| 91 | M&L for Granite (of any type) work 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick plaster in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. |
| 92 | S&F in repairs PTMT waste pipe 32 mm bore of length up to 80 cm for WHB / sink/unrinal pots, complete all as specified and directed. |
| 93 | S&F sink coupling suitable for dia 32 mm pipe PTMT (half or full threaded) . (Minimum weight 32 mm-45 gms/40 mm-60 gms) complete all as specified and directed. |
| 94 | S&F cast iron soil waste and vent pipes in any length with or without ears with lead joints in trenches or in floors or wall using Spun pipes CI pipes 100 mm bore pipes etc complete all as specified |
| 95 | S&F 100 mm bore Cast Itonbend, any radius complete all as specified and as directed. |
| 96 | S&F, 100 mm bore Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) Complete all as spd and directed. |
| 97 | S&F Grease separator Easy Clean ground Standard NS 7 , standard 740-1175mm, Class A/B for underground installation according to EN-1825 installation in frost-free depth • Installation is possible with groundwater up to the upper edge of the tank (UET) Class A/B = 700 mm ≤ DEC ≤ 1800 mm• Minimum installation depth achieved by sawing the upper section as required Consisting of upper section made of polymer, height and level adjustment, with cover class A/B, D in accordance with EN 124, made of cast iron (can be driven over by cars and trucks), sealed odour-tight, incl. lift-out key Sludge trap capacity-700 litres, Total seperator capacity-1100 litres, weight 315 Kg complete all as specified and as directed. |
| 98 | M&L Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in soft/loose soil all as specified and as directed |
| 99 | M&L cement concrete type D-2 1:4:8 (40mm graded aggregate) sub base as in floors and pavings of 100 thick all as specified and as directed |
| 100 | M&L Machine presses precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and as directed |
| 101 | Material and labour for point wiring for one light /fan/Exhaust fan point controlled by one switch with using 1.5 Sqmm FRLS (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduits (Medium grade) of size not less than 20 mm dia all as directed with sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchws, sockets, regulators etc including all accessories andusing 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. NOTE :-(I) The portion of point wiring at ceiling shall be in surface PVC conduit/ casing & caping of suitable size fixed on ceiling surface with using PVC rawl plugs.(ii)Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A\".(iii) The quoted rates shall be deemed to be inclusive for provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thicklaminated sheet fixed with suitable brass screws and cup washers |
| 102 | M & L forswitch flush type single pole one way 5 Amps, 240 volts, white ivory finish complete all as approved |
| 103 | M&L for ceiling rose surface Bakelite two to three terminal, 18 x 50 mm complete all as specified. |
| 104 | Supply & Fix for decorative slim linear LED tube light fitting 01x20 watt light with co extruded polycarbonate body, environmental frendly, energy efficient ready to use pack with all accessories including 01 No 20 watt tube rod and connecting the same to ceiling rose with using copper conductor 24/0.20 flexible PVC sheathsd and fixing arrangement for fixing the light fitting to wall/ roof surface complete all as specified & directed by Engineer in-charge |
| 105 | Supply and fixing Street/Security light fittings 1X35W new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with acrylic cover suitable for pole dia O 40mm(Max) with complete (40 mm GI pipe light grade ),clamp,nut-bolt and washers all directed by Engineer-in-Charge. |
| 106 | Supply and fixing of sheet metal enclosure Double door for DB’s4way 240 volts with 200 Amps rated bus bar for single phase and neutral supply complete fixed properly on in concealed position and to connect their incoming/outgoing electric connections by means of suitable sizes of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB’s of cables/wires all as directed. |
| 107 | S&F MCB single pole 6 to 32 Amps, \"B\" series10 KA ,240 Volts complete all as specified. |
| 108 | S&F MCB Single pole and neutral 40 to 63 Amps, \"B\" Series240 Volts complete all as specified. |
| 109 | Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directedat a level not exceeding 1.5 mtr above starting point complete all as specified and directed |
| 110 | M & L for cutting existing 80/50 mm dia GIpipe line in position for insertion of newtees for branch connection. |
| 111 | M&L for stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed of size 25 mm bore, complete all as specified and as directed. |
| 112 | Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 10 Sqmm , 2 core laid in trenches / duct / pipe etc complete all as specified and directed . |
| 113 | M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.Note- The punned thickness shall be measured and paid. |
| 114 | Supply and laying fine aggregate (sand) 25 mm thick spreading and levelling in layers n.exc. 25 mm thick including consolidation as specified and directed. |
| 115 | M&L bricks for coverunderground cable with one layer of bricks using sub class \"B\" bricks (Old size) laid flat across the cable complete all as specified. (Excavation and earth work will be measured separately). |
| 116 | Supplying & Fixing Tube medium grade galvanised of dia 50 sqmm for road crossing of cable and on pole and DB cable as in cable protection complete all as specified and directed. |
| 117 | Supplying & Fixing MCCB 3 Pole, 415 V, fixed type,40 Amps with breaking capacity 16 KA including all connection as required to panel complete all as specified and directed. |