| 1 | Periodical Maintenance and servicingof DG Sets of following capacity installed at various location under VSN Nagpur, replacement of spare parts, cleaning, oiling greasing, change of oil, replacement of filters, any type of pipe with fittings, , replacing `V\" belts of any type,water pumps gasket of any type, adjustment of tapit, , repairing of leakage of pipe, maintenance of self starter, alternator, dynamo, replacing carbon brush of any ,slip ring, automatic voltage regulator, battery with electrolite solution, terminals posts, repair of wiring in control panel using copper wirecomplete and and replacing contactor, relay, timer, MCCB, indicator lamp keeping DG set fully operationable condition all as directed.(a) DG set capacity 320 KVA 415 volts |
| 2 | (c) DG set capacity 125 KVA 415 volts |
| 3 | (d) DG set capacity 100 KVA 415 volts |
| 4 | (e) DG set capacity 82.5 KVA 415 volts |
| 5 | (f) DG set capacity 62.50 KVA 415 volts |
| 6 | (g) DG set capacity 50 KVA 415 volts |
| 7 | (h) DG set capacity 30/25/15 KVA 415 volts |
| 8 | NOTES FOR ITEM NO 1:-(i) The quoted rates shall deem to include cost of sufficent/ required man power employed for the maintanance purpose, T&P used and other petty items such as cotton waste, kerosene, oil, nuts, bolts and washerss etc complete includinglabour cost for fixing spares etc.(ii)During maintanance, any spares required to be replaced shall be paid under respective items hereunder. Fixing charges of same are deemed to be included in quoted rate for maintenance of DG sets. If spares are not included hereunder,then department will provide the same free of cost for fixing.(iii)The contractor shall be liable to provide adequate number of mechanics if required during the maintenance/break down without any extra cost to government for smooth functioning of various DG sets. (iv)Contractor shall visit each DG set prior quoting the rate to know the current status of respective DG set No claim on whatsoever account shall be entertained during curreny of work. |
| 9 | Supply only following materials/ spares for maintanance of DG sets of various capacities .To be changed if required at the time of maintanance of DG sets, labour cost deemed included in Item No 1.(a) Lubricant oil filter suitable for DG set 320 KVA Make: kirloskar |
| 10 | (c) Lubricant oil filter suitable for DG set 125 KVA Make: Cummins. |
| 11 | (d) Lubricant oil filter suitable for DG set 100 KVA Make: kirloskar |
| 12 | (e) Lubricant oil filter suitable for DG set 82.5 KVA Make: kirloskar |
| 13 | (f) Lubricant oil filter suitable for DG set 62.5 KVA Make: kirloskar |
| 14 | (g) Lubricant oil filter suitable for DG set 50 KVA Make: Cummins India. |
| 15 | (h) Lubricant oil filter suitable for DG set 30 KVA Make: kirloskar |
| 16 | (j) Lubricant oil filter suitable for DG set 25 KVA Make: kirloskar |
| 17 | (k) Lubricant oil filter suitable for DG set 15 KVA Make: kirloskar |
| 18 | Supply only fuel filter element with \"O\"ring suitable for following DG sets:-(a) DG set 320 KVA Make: kirloskar |
| 19 | (c) DG set 125 KVA Make: Cummins. |
| 20 | (d) DG set 100 KVA Make: kirloskar |
| 21 | (e) DG set 82.5 KVA Make: kirloskar |
| 22 | (f)DG set 62.5 KVA Make: kirloskar |
| 23 | (g) DG set 50 KVA Make: Cummins India. |
| 24 | (h) DG set 30 KVA Make: kirloskar |
| 25 | (j)DG set 25 KVA Make: kirloskar |
| 26 | (k) DG set 15 KVA Make: kirloskar |
| 27 | Supply only flexiable fuel pipe of suitable size with banzo washers for the following DG sets:-(a) DG set320 KVA |
| 28 | (b) DG set 82.5 to 125 KVA |
| 29 | (c)DG set 50 to 62.5 KVA |
| 30 | (d) DG set 15 to 30KVA |
| 31 | Supply only fan \"V\" belt for dynamo/ alternator of suitable sizes for the following DG sets:-(a) DG set 320 KVA |
| 32 | (b) DG set 82.5 to 125 KVA |
| 33 | (c)DG set 50 to 62.5 KVA |
| 34 | (d) DG set 15 to 30KVA |
| 35 | Supply only all Radiator rubber hose pipe with clamp complete of suitable sizes for the following engine of DG sets:-(a) DG set 320 KVA |
| 36 | (b) DG set 82.5 to 125 KVA |
| 37 | (c)DG set 50 to 62.5 KVA |
| 38 | (d) DG set 15 to 30KVA |
| 39 | (Supply only Air filter complete of suitable sizes for the following engine of DG sets:-a) DG set 320 KVA Make: kirloskar |
| 40 | (c) DG set 125 KVA Make: Cummins. |
| 41 | (d) DG set 100 KVA Make: kirloskar |
| 42 | (e) DG set 82.5 KVA Make: kirloskar |
| 43 | (f)DG set 62.5 KVA Make: kirloskar |
| 44 | (g) DG set 50 KVA Make: Cummins India. |
| 45 | (h) DG set 30 KVA Make: kirloskar |
| 46 | (j)DG set 25 KVA Make: kirloskar |
| 47 | (k) DG set 15 KVA Make: kirloskar |
| 48 | Supply only Lubricant oil 15 W 40WMake :- Castrol, BPCL ,K-Oil |
| 49 | Supply only Radiator coolant ready to use concentrate.Make:- K- COOL SUPER PLUS/ CASTROL |
| 50 | Supply only distilled water in supplier\"s packing. |
| 51 | Supply only brass battery terminals for DG Set Battery |
| 52 | Supply only battery connection copper lead with 200 amps rated capacity. |
| 53 | Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 90 AH of reputed make including charging andshifting & depositing oldbattery to MES all as specified as directed. |
| 54 | Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 100 AH of reputed make including charging andshifting & depositing oldbattery to MES all as specified as directed. |
| 55 | Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 180 AH of reputed make including charging andshifting & depositing oldbattery to MES all as specified as directed . |
| 56 | Supply only Fuel gauge indication assembly with indicator . |
| 57 | Supply only radiator cap with rubber gasket complete all as specefied and directed. |
| 58 | Supply only fuel tank cap withrubber gasket complete all as specefied and directed. |
| 59 | Supply and replacement of Digital VAF + PF Meter, flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring. Make L&T, Cat No WL411021OOOO |
| 60 | Surface excavation/dressing n exc 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and removing rubbish to a distance of 50 mtr outside the periphery of area as directed |
| 61 | Material and labour for painting of DG Set canopy and control panelwith synthetic enemel paint One coats by spray painting approved colour after scraping of old paint with sand paper, cleaning of all rusted portion, surface including sign writing i.e MES No, Make, Capacity etc complete all as directed.(a) DG set 320 KVA |
| 62 | (b) DG set 82.5 to 125 KVA |
| 63 | (c)DG set 50 to 62.5 KVA |
| 64 | (d) DG set 15 to 30KVA |
| 65 | M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25X4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soilto a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMTbars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth leadprotection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. |
| 66 | M&L forEarth continuty conductor or main earthing lead as 25x4 mm GI strip fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit /pipe or fixed to pole or any other situation for loop earthing etcall as directed by Engineer-in-charge |
| 67 | Material & Labour for MK2PN contact Plug In Relay Octal type base 8 Pin DPDT Relay, Contact Rating: 10A @ 250VAC/30VDC including dismentling of old relay complete all as specified and directed. |
| 68 | Material and labour for 4 Nos Wheel opening , hub greasing, Re-tighten the u-bolt & Replace the individual leaves bend the individual metal sheets to the right curvature and Lubrication of entire leaf spring for DG Set Trolley of capacity 125 KVAcomplete all as specified and directed.Replacement of following items:-. |
| 69 | (a) Wheel oil seal |
| 70 | (b) Wheel bearing |
| 71 | (c) Grease |
| 72 | Material & Labour for DG Set engine and AMF Controller DGC-6D,Control Mode MANUAL/AUTO and Generator controller with all require engine safeties. Having auto mode facility with a single signal input as a auto input including dismentling of old relay complete all as specified and directed. Make: PROCOM (PT: DGC6-D) SN:2016102740 |
| 73 | Material & Labour for hard rubber base Three Phase Kirloskar KG 934 V2 Genset Controller, IP Rating: Ip40, UNIVERSAL, Control Mode MANUAL/AUTO and Generator controller with all require engine safeties. Having auto mode facility with a single signal input as a auto input.Controller is having standard require paramenters as configure from KOEL including dismentling of old relay complete all as specified and directed. Make: Kirloskar Green (KG 934 V2 Genset Controller, IP Rating: Ip40, UNIVERSAL) |
| 74 | Material & Labour for Hard Rubber Base Three Phase Kirloskar KG 640 Genset Controller, IP Rating: Ip40, UNIVERSAL, Control Mode MANUAL/AUTO and Generator controller with all require engine safeties. Having auto mode facility with a single signal input as a auto input.Controller is having standard require paramenters as configure from KOEL including dismentling of old relay complete all as specified and directed. Make: Kirloskar Green |
| 75 | Material & Labour for Hard Rubber Base Three Phase KirloskarKG 934 V1 Genset Controller, IP Rating: Ip40, UNIVERSAL, Control Mode MANUAL/AUTO and Generator controller with all require engine safeties. Having auto mode facility with a single signal input as a auto input.Controller is having standard require paramenters as configure from KOEL including dismentling of old relay complete all as specified and directed. Make: Kirloskar Green |
| 76 | Disconnecting old VMR, Supply and fixing Digital Voltage moitoring Relay (PR-07) VMR Proton Model PR-07 3 phase protection against Over voltage, uder voltage, single phasing, reverse phasing and unbalance supply compele all as spec ified and directed. Features :- Press INC key in running condition to bserve particular supply voltage, Message display for SPP, Reverse phasing & unbalance faults, Indication for low voltage, high voltage, SPP & relay ON, Micro controller based technology, Wide range of supply variation, Unit will also work if one phase is present, all the se points settable by keys, trip delay for unnder voltage and unbalance is settable and Reverse Phasing Protection can be able to bypass through sttinngs. Make : Proton Model No PR-07 |
| 77 | Material & Labour for MCCB 250 Amps 25 KA, 4 Pole with Thermal Magnetic setting including dismantling of old one complete all as specified and directed.Make: Legrand/Havells/L&T/Schnieders |
| 78 | Material & labour for MCCB 160 Amps 16 KA, 4 Pole including dismantling of old one MCCB testing and commissioning complete all as specified and directed. Make : Legrand/Havells/L&T/Schnieders |
| 79 | Material & labour for MCB TPN 63 Amps 10 KA with encloser inexisting panel with incoming and outgoing connection complete all as directed Make complete all as specified and directed by Engineer-in-Charge. Make : Legrand/Havells/L&T/Schnieders |
| 80 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed. |
| 81 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. |
| 82 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 83 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed . |
| 84 | M & L for DWC pipe of 75 mm dia for cable protection complete all as specified and as directed. |
| 85 | Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 100 mm bore for protection of cable complete all as specified and directed. |
| 86 | Supply and laying in trenches/Floor or fixed to Pole/Wall GI pipe light grade with fitting of size 40 mm bore for protection of cable complete all as specified and directed. |
| 87 | M&L for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 sqmm. 3.5 copre including taking down all as specified and directed. |
| 88 | Dismantling the fuel pump/FIP from the Engine, transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve, plunger, copper washer etc all as required including re-calibration, refixing and testing complete. (a) DG set 320 KVA |
| 89 | (b) DG set 82.5 to 125 KVA |
| 90 | (c)DG set 50 to 62.5 KVA |
| 91 | (d) DG set 15 to 30KVA |
| 92 | Taking downradiator, servicing, cleaning of with suitable reagent, washing thoroughly,arresting leakage if any by welding / brazing and refixing the same (Necessary coolant and distilled water required will be measured and paid seperately under ).(a) DG set 320 KVA |
| 93 | (b) DG set 82.5 to 125 KVA |
| 94 | (c)DG set 50 to 62.5 KVA |
| 95 | (d) DG set 15 to 30KVA |
| 96 | Removing dismantling and overhauling of 12 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed. |
| 97 | Removing dismantling and overhauling of 24 volt starter motor, replacement of armature coil, field coil, bush bearing etc to make the starter motor serviceable complete all as specified and as directed. |
| 98 | Supply and fix CONTACTOR, 500 AMP, 600 VAC, 50/60 HZ, COIL: 440-500 V for 320 KVA DG set including dismentling of old contactor complete all as specified and directed CK SERIES : CK10CE300 Make:GE |
| 99 | Supply and fix MCX 22 Contactor for 50/62.5 KVA DG setSeries: CS97017FOO 100A 4P 415V AC AC-1 240V AC Coil 50/60 Hz including dismentling of old contactor complete all as specified and directed. |
| 100 | Supply and fix ADD NO BLOCK MNX/MCX 2NO + 2N including dismentling of oldcomplete all as specified and directed |
| 101 | Supply and fix MCX 33/31 Contactor for 82.5/100 KVA DG setSeries: CS97021BOOO 200A 4P 415V AC AC-1 240V AC Coil 50/60 Hz including dismentling of old contactor complete all as specified and directed. |
| 102 | Supply and fixContactor 50A 4P 240V AC Coil 50/60Hz AC for 25 KVA DG Set including dismentling of old contactor complete all as specified and directed.KOEL Make(Type:KCL 24 32) |
| 103 | Supply and fixNHP Battery Charger 24Volts 10Amps Generator Battery Charger for 320 KVA DG including connecting items all as specified and directed. |
| 104 | Supply and fixNHP Battery Charger 12 Volts 10Amps Generator Battery Charger for 25/30/50/62.5/82.5/100/125 KVA DG set including connecting items all as specified and directed. |
| 105 | Supply and fix DGC-2007 Governor Controller P/n 65.11220-7011 for 320 KVA DG set including dismentling of old controller complete all as specified and directed |
| 106 | Supply and fix Turbo charger GARRETT A/R 60 M24 for Engine Sr no-KL 6.5001(320 KVA) DG set including dismentling of old turbo charger complete all as specified and directed |
| 107 | Supply and fix controller kirloskar series CE20220901053 for 320 KVA DG set including dismentling of old Controller complete all as specified and directed. |
| 108 | Supply and fix Dse4520mkii Diesel Generator Automatic Controller for 82.5 KVA DG set including dismentling of old Controller complete all as specified and directed. |
| 109 | Supply and fix SEDEMAC GC1202 Diesel Generator Automatic Controller for 30KVA DGset including dismentling of old Controller complete all as specified and directed. |