Tender For Installation Of Safety-Related Signage On The Chadra Bridge And Its Approaches At Kilometer 3 Of The Bareilly-Sitapur Bypass (Maholi)., Sitapur-Uttar Pradesh
TDR : 53711963
Tender Notice
BOQ
5 Days Left
Sitapur
Uttar Pradesh
Tender For Installation Of Safety-Related Signage On The Chadra Bridge And Its Approaches At Kilometer 3 Of The Bareilly-Sitapur Bypass (Maholi).
Name of Work:- बरेली सीतापुर बाईपास (महोली) के कि0मी0-3 में स्थित चड़रा पुल व एप्रोच के सुरक्षा सम्बन्धी साइनेज का कार्य।
Sl. No.
Item Description
1
Type - A, \"W\" : Metal Beam Crash Barrier (Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) [Morth Chapt. Summary 8.23)
2
Retro-reflectorised Traffic sign as per IRC-67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67- 2012 made of high intensity grade sheeting type-IV vide clause 801.3, fixed over aluminium sheeting 1.5 mm thick supported on a mid steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from Intemational/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-00) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer/Client, if so desires. could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012. Legends, letters, numerals and borders etc should be as per MoRTH specification No-801.3.7 Proof of the same in form of government report shall be uploaded while quoting tender. LKO SOR CH-26 MoRTH 801 (8.4) Chevoron Board Single Rectangle Size (50x60cm)
3
Providing and erecting direction and place identification retro-reflectorised sign as per IRC-67 upto date made of high intensity grade sheeting The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67 upto date. Legends , letters , numerals and borders etc should be as per MoRTH specification No-801.3.7 . Sheet fixed over aluminium sheeting ,2 mm thick with area exceeding 0.9 sqm.Supported on a mild steel double angle iron post 75x75x6 mm firmly fixed to the ground by means of property designed foundation with PCC M-25 grade cement concrete 45x45x60 cm,60cm below ground level as per approved drawing, complete. as per SOR Ch-26 SI No.-20 Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.