| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 9 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 10 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 13 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 14 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia |
| 15 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 16 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-Charge. |
| 17 | Providing and fixing 300 mm sweep Ventil Air exhaust fan light duty with suitable louver /shutter in existing opening hole including making good the damage, testing, commissioning, connection etc as required at site.(Havells/CG/Usha/Bajaj Make) |
| 18 | Providing and Fixing of 1X1 Feet 24 watt square / round surface / recess mounted LED slim downlight fitting complete with electronic driver & complete with all accessories etc as required. (Crompton/ Havells / Philps /Bajaj / make) |
| 19 | Providing and fixing of 10 watt LED Mirror light fitting indoor decorative integrated type complete with all accessories directly on wall / ceiling including connection with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and earthing etc as required at site.(Havells CG/Philips/Bajaj Make) |
| 20 | Providing and fixing of 9 watt B-22 (Bayonet Cap) LED bulb 3 star, 220-2240 V AC, 50/60 Hz, 800-900 lumens, 4000K-4500K cool white, power factor not less than 0.9, life span 15000 to 25000 hours, Plastic and aluminium or polycarbonate housing Etc complete as required. (Havells CG/Philips/Bajaj Make) |
| 21 | Providing and fixing of Hand Dryer Automatic Sensor for Bathroom of Stainless Steel Fast Dry Hand Dryer Satin Finish on existing wall, 240 Volt, 50 Hz including electric connection etc as required.(Euronics / Dolphy /JPS /Ringwell make) |
| 22 | Providing of one number of PVC Sheathed PVC insulated XLPE aluminium Conductor armourd Power cable of 1.1 KVgrade of following sizeas required. The cable should conform to IS 7098 (Part1) 1988 with upto date amendents if any. a) 3.5 x 25 Sqmm |