| 1 | Repairs to windows |
| 2 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc. complete. Hot finished welded type tubes, for window grills |
| 3 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (Asian Tractor / Jonson Nicholson/Berger) |
| 4 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required size and of approved quality, all complete as per the approved drawing & direction of the Engineer-in-Charge. (Single/double glass Sqm 22 10,874=20 2,39,232 panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels)made of (small series) frame 92 x 44 mm & sash 32 x 60mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 5 | Providing and fixing aluminum work for ventilators with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminum (minimum thickness of powder coating 50 micron) as per approved colour |
| 6 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 7 | Providing aluminum portion and aluminum door to newly converted cold room to office room |
| 8 | Providing and fixing aluminum work for partions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminum (minimum thickness of powder coating 50 micron) as per approved colour |
| 9 | Providing and fixing glazing in aluminum door, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 10 | For shutters of windows including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness Kg 09 634=45 5,710 of powder coating 50 micron) |
| 11 | Providing and fixing 09 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Gradel Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete asper architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination onone side and balancing lamination on other side |
| 12 | Supplying and fixing automatic door closure slim as per approved sample |
| 13 | Providing two leaf aluminium door to seed cold storage entrance |
| 14 | Providing and fixing aluminium work for door with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) as per approved colour |
| 15 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 16 | For shutters of windows including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 17 | Providing and fixing 09 mm thick pre laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Gradel Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 18 | Supplying and fixing heavy duty floor spring as per approved sample including dismantling concrete |
| 19 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 20 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete (Birla and equivalent) |
| 22 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work window grill and rolling shutter wherever required |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (Asian Tractor / Jonson Nicholson/Berger/Nerolac) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (Asian Tractor / Jonson Nicholson/Berger/Nerolac) |
| 25 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. , As per manufacturer\"s specification. (Asian Tractor / Jonson Nicholson /Berger/Nerolac) |
| 26 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface. for (Asian Tractor / Jonson Nicholson /Berger/Nerolac) |
| 29 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 30 | Providing Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 31 | Finishing walls with textured exterior paint of required shade Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. |
| 32 | Providing sheet cover to roof portion for the main seed machine |
| 33 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 0.05 % total coated thickness, Zinc coating 120gsm as per IS: 277 in 240 mp a steel grade, 5-7 microns epoxy both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete tiled shaped as per approved sample for roof plain sheet |
| 34 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, etc. complete. Hot finished welded type tubes, for window grills |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (Asian Tractor / Jonson Nicholson/Berger) |