| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group- B |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required B) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. A) 3 x 1.5 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. B) 3 x 4 sq. mm |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 20 mm |
| 7 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. A) 15/16 amp switch |
| 8 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. B) 6 pin 15/16 amp socket outlet |
| 9 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 10 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 11 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 12 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single Pole |
| 13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
| 15 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 16 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia |
| 17 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 18 | Providing and fixing 300 mm sweep Ventil Air exhaust fan heavy duty with suitable louver /shutter in existing opening hole including making good the damage, testing, commissioning, connection etc as required at site.(Havells/CG/Usha/Bajaj Make) |
| 19 | Supply, installation, testing and commissioning of 20 watt LED tube fittings prewired for LED tube, complete with all accessories and LED tube directly on ceiling/ wallincluding connection with 1.5 sq. mm FRLS PVC insulated copperconductor single core cable etc as required. ( Havells MAKE or Philips/CG/Bajaj make) |
| 20 | Providing and Fixing of 12 watt square / round surface / recess mounted LED slim downlight fitting complete with electronic driver & complete with all accessories etc as required. (Havells / Philps /Bajaj /Crompton make) |
| 21 | Providing and fixing of 10 watt LED Mirror light fitting indoor decorative integrated type complete with all accessories directly on wall / ceiling including connection with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and earthing etc as required at site.(Havells CG/Philips/Bajaj Make) |
| 22 | Providing and fixing of stroage type water heater (Geyser) of capacity 25 Ltr, vertical type 5 star with complete accessories in existing wall, 240 Volt, 50 Hz including connection pipe 02 Nos and making electric connection etc as required.(Havells/ Bajaj/ Racold make) |
| 23 | Supplying and fixing Bus-Bar chamber with 100 Amps, 415 volts,4 way .copper bus bars, Complete with connections, earthing the body etc. as required. AnchorMake Item Code 98377 or other equivalent Havells etc. |
| 24 | Providing of one number of PVC Sheathed PVC insulated XLPE aluminium Conductor armourd Power cable of 1.1 KVgrade of following size as required. The cable should conform to IS 7098 (Part1) 1988 with upto date amendents if any. a) 3.5 x 25 Sqmm |