| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required B) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. A) 3 x 1.5 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. B) 3 x 4 sq. mm |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 20 mm |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 8 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 9 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 10 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) Single Pole |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A) 4 X 35 sq. mm (32mm) |
| 12 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 35 sq. mm |
| 13 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 14 | Providing and fixing 300 mm sweep light duty Ventil Air exhaust fan light duty with suitable louver /shutter in existing opening hole including making good the damage, testing, commissioning, connection etc as required at site.(Havells/CG/Usha/Bajaj Make) |
| 15 | Providing and fixing of stroage type water heater (Geyser) of capacity 25 Ltr, vertical type 5 star with complete accessories in existing wall, 240 Volt, 50 Hz including connection pipe 02 Nos and making electric connection etc as required.(Havells/ Bajaj/ Racold make) |
| 16 | Providing and Fixing of 1X1 Feet 24 watt square / round surface / recess mounted LED slim downlight fitting complete with electronic driver & complete with all accessories etc as required. (Crompton/ Havells / Philps /Bajaj / make) |
| 17 | Providing and fixing of 10 watt LED Mirror light fitting indoor decorative integrated type complete with all accessories directly on wall / ceiling including connection with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and earthing etc as required at site.(Havells CG/Philips/Bajaj Make) |
| 18 | Providing and fixing of 9 watt B-22 (Bayonet Cap) LED bulb 3 star, 220-2240 V AC, 50/60 Hz, 800-900 lumens, 4000K-4500K cool white, power factor not less than 0.9, life span 15000 to 25000 hours, Plastic and aluminium or polycarbonate housing Etc complete as required. (Havells CG/Philips/Bajaj Make) |
| 19 | Providing and laying one number of PVC Sheathed PVC insulated XLPE aluminium Conductor armourd Power cable of 1.1 KVgrade of following sizein the existing RCC/ HUME/ METAL/DWC pipe as required. The cable should conform to IS 7098 (Part1) 1988 with upto date amendents if any. a) 4 x 35 Sqmm |