| 1 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, ismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 3 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plnth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 8 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 9 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 10 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood |
| 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 12 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 13 | Providing and fixing aluminium handles, ISI marked, anodised (anodic oating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm |
| 14 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 15 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average widt of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm |
| 16 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard ar, ladder, railings, brackets, gates and similar works |
| 17 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 18 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 19 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated \"J\" or \"L\" hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick flat |
| 20 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 25 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 26 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 27 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 28 | Renewing glass panes and refixing existing wooden fillets:Float glass panes of nominal thickness 4 mm(weight not less than 10kg/sqm) |
| 29 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 30 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 31 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 32 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore |
| 33 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 34 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 35 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 36 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm |
| 37 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. ofv quality and make as approved by Engineer - in - charge. |
| 38 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 39 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 75 mm outlet Sand cast iron S&S as per IS - 3989 |
| 40 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% |
| 41 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 43 | 20 mm nominal dia Pipes |
| 44 | 25 mm nominal dia Pipes |
| 45 | Making connection of G.I. distribution branch with G.I. main of followingsizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 46 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore Vertical |
| 47 | Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length15 mm nominal bore |
| 48 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : |
| 49 | 15 mm nominal bore |
| 50 | 20 mm nominal bore |
| 51 | 25 mm nominal bore |
| 52 | Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 90 mm long, weighing not less than 93 gms |
| 53 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 15 mm nominal bore, 105 mm long, weighing not less than 138 gms |
| 54 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks |
| 55 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 56 | Grading roof for water proofing treatment with Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 57 | Repairing the steel gateincluding taking out and refixing, cutting, welding etc. complete as per direction of Engineer in-charge. (Replacement of rusted steel to be paid seprately) |
| 58 | Providing and fixing CP brass overhead shower(Make Cera cat no. F-7020108AB or equivalent of Jaquar, Kohler, Grohe ) overhead shower 80 mm dia with 200 mm long shower arm and wall flange etc complete.in all respect. |
| 59 | P/F 15 mm CP brass swan neck pillar cock(Make Cera cat no. F2002105 or equivalent of Jaquar, Kohler, Grohe). |
| 60 | P/F CPVC F T A/ M T A with reducer sokit 20 mm dia. of approved quality(Supreme make or equalent) |
| 61 | P/F CPVC F.T.A./ M.T.A. (Brass Insert)with reducer sokit 25 mm dia. of approved quality (Supreme make or equalent) |
| 62 | P/F CPVC ball valve 20 mm dia. of approved quality(Supreme make or equalent) |
| 63 | P/F CPVC ball valve 25 mm dia. of approved quality(Supreme make or equalent) |
| 64 | P/F CP brass 2-way Bib cock/ angle valve with single handle and wall flange 15 mm nominal bore of approved make (Make Cera cat no. F2002211 or equivalent of Jaquar, Kohler, Grohe ) |
| 65 | P/F hand shower (Health Facuet)(ABS Body) with 8 mm dia 1 meter longflexible tube and wall hook (Make Cera cat no.F8030108AB or equivalent of Jaquar, Kohler, Grohe ) complete.in all respect. |
| 66 | P/F CP brass wall mixer of approved quality with necessary taflon tape, washer etc all complete. (Make Cera QT F2006404 HT F3001404 or equivalent of Jaquar, Kohler, Grohe ) Wall mixer with telephonic shower arrangement. |
| 67 | Providing and fixing CP brass Towel rail 600 mm (24”)(Make Cera cat no. F5004103 or equivalent of Jaquar, Kohler, Grohe ) complete.in all respect. |
| 68 | Providing and fixing C.P. brass angle valve 15 mm nominal bore (Make Cera cat no. F2008201 or equivalent of Jaquar, Kohler, Grohe ) |
| 69 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore(Make Cera cat no. QT F-2006152 or equivalent of Jaquar, Kohler, Grohe ) |
| 70 | P/F PVC water storage tank cover threaded lid with frame 500 to 1000 ltr capacity with locking arrangement etc complete. |
| 71 | Providing and fixing a custem-built cupboard with total over all depth of 600 mm. The main structure of the cupboard including the sides, top, bottom, shelves and shutters shall be febricated using 18 mm thick HDHMR (one side prelemineted ) bord of approved brand such as Action, Tesa, Green ply, or century. The rear pennal shall be made from 8 mm thick HDHMR(one side prelemineted ) the exteror must be coverd with sunmica as well the sunmica shall be of approved brand only. The scope includes supplying ans installing all necessary hardwere fittng and fixtures, such as hinges, handels, Godrej multipurpose locks, stopers, screws and other accessories. The entire work shall be carried out as per the instructions of the Engineer in-charge, ensuring proper allgnment, finishing and durability. (Note:- For the purpose of payments only the frunt face area of the cupboard will be mesured in squire metres, internal details will not be measured separately.) |
| 72 | Providing and fixing concealed stop cock regular body aid (Jaquar make ALD-CHR-083 L or equivalent of Kohler, Grohe) complete as per direction of Engineer in-charge. |
| 73 | P/F 15 mm CP brass pillar cock(Make Cera cat no. QT F2006101 or equivalent of Jaquar, Kohler, Grohe). |
| 74 | Repair the damaged GI pipe line with required GI pipe and fittings etc complete as per direction of Engineer –in-charge 25 mm nominal bore. |
| 75 | Uprooting stay unwanted vegetation/ peepal tree etc from wall and terrace upto floor level i/c repair of damaged wall & plaster and making good the same as per existing finishing as directed by Engineer-in-charge. |
| 76 | Cleaning floor tiles/ wall tiles and all flooring by washing powder & repair joints with white cement in colour pigment for matching etc complete |
| 77 | Providing and fixing water metre (15 mm dia) at main jal bord line (Kranti make equivalent of Teksan, Itron, Fedrel) etc. complete as per direction of Engineer in-charge. |