| 1 | SITC of Medical Grade Copper Pipe on hanger/support through routing (BSI Kite Mark and CE Compliance Copper Pipes) conforming specifications attached of following sizes:22 mm ODx1 mm thick |
| 2 | SITC of Line Isolation Valves of following sizes.22mm ball valve |
| 3 | SITC of Gas Outlet for Oxygen and conforming specifications attached |
| 4 | SITC of Gas Outlet for Vacuum and conforming specifications attached |
| 5 | SITC of Gas Outlet for Medical Air 4 Bar and conforming specifications attached |
| 6 | SITC of Oxygen Flow meter and conforming specifications attached. |
| 7 | SITC of Humidifier Bottle and conforming specifications attached |
| 8 | SITC of Vacuum Regulator and conforming specifications attached |
| 9 | SITC of 600ml collection jar with lid and bracket and conforming specifications attached. |
| 10 | SITC of H. P. Rubber Tube for Vacuum |
| 11 | Installation of MGPS bed head panel with required modifications for Medical gases outlets 03 Nos installation and commissioning of nurse call system as per the site requirement |
| 12 | Monitor Stand (Wall Mounted/Rail Mounted) |
| 13 | SITC of Stainless Steel Probes (BS Standard) |
| 14 | LS for dismantling and fixing of Gypsum board as per the site requirement for laying copper pipe above ceiling |
| 15 | Supplying and fixing of following sizes of steel conduitalong with accessories in surface/recess includingpainting in case of surface conduit, or cutting the walland making good the same in case of recessedconduit as required.25 mm |
| 16 | Supplying and fixing of following sizes of steel conduitalong with accessories in surface/recess includingpainting in case of surface conduit, or cutting the walland making good the same in case of recessedconduit as required.32 mm |
| 17 | Supplying and fixing of following sizes of mediumclass PVC conduit along with accessories insurface/recess including cutting the wall and makinggood the same in case of recessed conduit asrequired.25 mm |
| 18 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired.3 x 4 sq. mm |
| 19 | Supplying, drawing, Installation, Testing andcommissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6Unshielded Twisted Pair, 4 pair should be complied asper UL/ETL verification program for compliance withANSI/TIA-568.2-D standard. Outer diameter should bein the range of 6.1mm nominal with OperatingTemperature Range : -5° to +60°C, Bending Radius :< 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.1 Run of cable |