| 1 | Design, fabricate, Supply, Erections of the High Mast with the help of suitable equipment’s with maximum safety of the erection worker at site 24Mtr.High Mast pole (excluding the Ht. of head frame) with head frame of suitable size as per the design with caged ladder and platform with railing for maintenance of the Flood lights along with all its Accessories, nut bolts etc. conforming to the Specifications of the contract. High mast shall be of continuously tapered, polygonal cross section, minimum 8 sided or equivalent, presenting a good and pleasing appearance, assured performance, and reliable service. The height of mast pole shall be at 24 m, with minimum across Flatdimensions of 200mm at top.The plate thickness shall be 5mm for bottom and 4 mm for top section or equivalent and suitable for wind velocity as per IS 875 part 3. The 24 meter high mast shall be delivered either in Two or maximum three two sections, and shall be joint together by slip stressed -fit method at site.The minimum over lap distance shall be 1.5 times the diameter at penetration entire fabricated mast shall be hot dip galvanized, internally and externally as per BS EN ISO 1461 having a uniform thickness of 65 microns. It shall also include accessories for high mast including head frame arrangement suitable for mounting 24 luminaries LED FLOOD LIGHT symmetrically. Suitable head frame as per the design for the required illumination across the designed illumination beam to be designed, fabricated and fixed over the pole. The tilt angle and curvature of the head frame to be designed so as to get the class III illumination of cricket ground as per SP Including supply of foundation bolts manufactured from special steel min.6.8 grade along with nuts, washers, anchor plate and templates (1 fitting per mast is necessary) as per specification and direction of the Engineer - In- Charge. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) |
| 2 | Design, Supply, and wiring of Luminaries with all wiring materials & labours. of high-quality integrated LED Flood Light with a minimum system lumen of 56,000Lm and system wattage not exceeding 450W with a nominal efficiency 120Lm/W. Luminaire should have CCT of 5700K with SDCM <5 and CRI >70. Fixture should be available with Asymmetric wide, symmetric narrow and specially designed FLNB beam optics for sports application. The housing should be of non-corrosive high pressure die-cast aluminum to stand with extreme environments, having corrosion resistant powder coating to pass NSS of 500 Hrs. Product should be suitable for continuous operation(10-12 Hrs. per day), withlifetime of 50K hours@L70. The Ingress protection should be minimum IP66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. While accessing the gear compartment, the optical compartment should not be accessible. The luminaire should have a 20 KV /10 KA SPD duly bolt edin the luminaire,with PF>0.95.The SPD shouldbeable to sustain a minimum 15 hits of 10KA rating i.e. total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should have a breather to ensure that air balance inside and outside of the compartment. The luminaire should be of Class B serviceability. The wattage of each LED should be greater than 1watt and less than 3Watt. Only high power single white LED chip with ceramic based suitable for outdoor use is allowed. Multi-chip, array multi-die, mid power, integrated arrays and COB’s are not permitted. Array of light connection should be in parallel not in series. The HP LED used in the luminaire shall be SMD type only of make Lumiled, Osram, Nichia, and CREE. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs. should have an auto shutdown @325V and have an auto recovery feature. The Drivers should be apotted driver notaprintedcircuitboard without casing, mounted inside the luminaire. The weight of the luminaire should not be more than 12 Kg (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) |
| 3 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70 sq. mm 3-1/2 core (Including all material ,labour, machinery & NOC from Concern department) |
| 4 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 4 sq. mm 3 core (Including all material ,labour, machinery & NOC from Concern department) |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core (Including all material ,labour, machinery & NOC from Concern department) |
| 6 | S&F of 63 Amp. DP MCB (10 KA) (Including all material ,labour, machinery & NOC from Concern department) |
| 7 | Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compart mentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after7 tank treatment process,cablealley, inter connection with suitable size copper conductor cable/solid copper strip, having switch gearsandaccessories,mountingsand internal wiring, earth terminals, numbering etc. complete in all respect, as per CPWD specification with following in coming and Out goings,suitable for operationon 415V,3phase, 50HzAc Supply with enclosure protection class IP 42 as required :INCOMING: 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0- 500V with select or switch Digital Ammeter (0-250A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, tripindicating lamps Se tof Aluminum Bus Bar 300 AOUTGOING: 04 nos. 63 A, 50kA TPN MCCB, Ics=100% Icu, with over load protection (Including all material ,labour, machinery & NOC from Concern department) |
| 8 | Excavation in foundation by manual means in ordinary soil (Loam, clay or sand) including lift upto 1.50m and lead upto 30m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in charge upto a distance of 30m from the foundation trenches.(Including all material ,labour, machinery) |
| 9 | Concrete with 40mm Gauge approved Stone ballast coarse sand of 2.20 - 3.60 F.M and cement in proportion of 8 : 4 : 1 in foundation and under floors including supply of all material, labour and T & P etc. Required for proper completion of the work. (Including all material ,labour, machinery) |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; including the cost of centering, shuttering, finishing and excluding reinforcement as per direction of the engineer-in-charge; for the M-25 grades of concrete.(Including all material ,labour, machinery) |
| 11 | M.S. or TMT bars(FE-500D grade or higher) or HYSD Bars or iron in plain work such as R.C.C. or Column work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of work shape and including supply of steel. (Including all material ,labour, machinery) |
| 12 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (Including all material ,labour, machinery & NOC from Concern department) |
| 13 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all material ,labour, machinery & NOC from Concern department) |
| 14 | Supply & Fixing of *20 KW Power Plant (off grid) *545-550watt solar Panel -110 No’sSolar Photovoltaic (PV) Modules Description: Providing 110 high- performance solar PV modules each rated at 550 Wp (Watt-peak). These state-of-the-art panels are designed to maximize energy 90 TO 96.5% yield with the following advanced features: ● Half-Cut Cells: Engineered with half-cut cell technology, allowing uninterrupted energy production even when part of the panel is shaded. ● Low Light Performance: Capable of generating power under low sunlight conditions, ensuring consistent energy output throughout various weather conditions. Performance and Warranty: ●Performance Warranty: 25 years, with annual degradation less than 0.45%.● Operational Temperature Range: - 40°C to +85°C (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 15 | Supply & Fixing of 48 VOLT 1000 AH SOLAR LITHIUM 20KWH BATTERY PACK Rated 48v 1000Ah 20 kwh energy Display cells voltage and system voltage.Temperature of cells and MOS/BMS Charging/Discharging current Display Capacity and State of Charge Display(SOC) (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 16 | Supply & Fixing of Solar hybrid inverter of 20 kw three phase (MNRE & BIS approved) With 05-year warranty Providing a high-efficiency 50 kW inverter approved from M.N.R.E and B.I.S . Inverter is designed to convert the DC output of the solar panels into AC power suitable for grid connection. Key features include: ● High Conversion Efficiency: Up to 98.4% efficiency ensures maximum energy utilization.● Advanced MPPT Technology: Equipped with Multi-Point Power Tracking (MPPT) to optimize energy harvest from each panel string under varying environmental conditions. ● Robust Grid Compliance: Supports seamless integration with the grid, adhering to local standards and regulations. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 17 | Supply & Fixing of robust galvanized iron (GI) mounting structure for the solar panels, designed to ensure secure and efficient installation. This GI structure is crafted through a meticulous process involving the melting of iron ore and coal,followed by the removal of impurities. This results in a durable, corrosion-resistant frame that can withstand harsh environmental conditions. Engineered to withstand wind speeds of up to 180 km/h, making it suitable for various climatic conditions. ● Tilt Angle: Fixed at 22 degrees, optimizing the angle for maximum solar energy capture throughout the year. Mechanical Data: ● Coating: Hot- dip galvanized to provide superior corrosion resistance and longevity. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 18 | Electrical Cabling and Conduits Supply & Fixing of utilizing high-quality electrical cabling and conduits , a leading manufacturer renowned for its robust and reliable wiring solutions. products are known for their superior quality, durability, and compliance with international safety standards (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 19 | Supply & Fixing of DCDB (Direct Current Distribution Box): Input of Solar Panels: DCDB is connected directly to the solar panels, where it receives the DC power generated by the panels. Each string of solar panels is typically connected to a DC combiner box to consolidate the DC power output before it reaches the DCDB. Protection and Safety: DCDB includes various protective devices such as fuses, circuit breakers, surge protection devices, and isolators. These devices are essential to ensure the safety of the solar plant by preventing overcurrent, overvoltage, and short-circuits that can damage the panels or other components .Monitoring and Control: DCDB may also include monitoring and control devices such as string-level monitoring systems. These systems help detect any issues with individual strings of panels, enabling early detection and maintenance.DC to AC Inverter Connection: The DC power from the solar panels is fed into inverters, which convert it into AC power for use in the electrical grid. The DCDB facilitates the connection between the inverters and the DC source. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) (For 20 kw solar power plant) |
| 20 | Earthing in Solar Photovoltaic (PV) systems is crucial for safety and system integrity. It involves connecting the system’s conductive elements to the ground, creating a path for fault currents to safely dissipate, and preventing electric shock. Solar PV Systems differ from traditional electrical systems, in that they generate direct current (DC), which is then converted to alternating current (AC) by an inverter. Key Components requires proper grounding include solar panels, inverters and lightning protection systems. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 20 kw solar power plant) |
| 21 | Supply & Fixing of *60 KW Power Plant (off grid) *545-550watt solar Panel -110 No’s Solar Photovoltaic (PV) Modules Description: Providing 110 high- performance solar PV modules each rated at 550 Wp (Watt-peak). These state-of-the-art panels are designed to maximize energy 90 TO 96.5% yield with the following advanced features: ● Half-Cut Cells: Engineered with half-cut cell technology, allowing uninterrupted energy production even when part of the panel is shaded. ● Low Light Performance: Capable of generating power under low sunlight conditions, ensuring consistent energy output throughout various weather conditions. Performance and Warranty: ●Performance Warranty: 25 years, with annual degradation less than 0.45%. ● Operational Temperature Range: - 40°C to +85°C (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 22 | Supply & Fixing of 48 VOLT 1000 AH SOLAR LITHIUM 60KWH BATTERY PACK Rated 48v 1000Ah 60 kwh energy Display cells voltage and system voltage.Temperature of cells and MOS/BMS Charging/Discharging current Display Capacity and State of Charge Display(SOC) (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 23 | Supply & Fixing of Solar hybrid inverter of 60 kw three phase (MNRE & BIS approved) With 05-year warranty Providing a high-efficiency 50 kW inverter approved from M.N.R.E and B.I.S . Inverter is designed to convert the DC output of the solar panels into AC power suitable for grid connection. Key features include: ● High Conversion Efficiency: Up to 98.4% efficiency ensures maximum energy utilization. ● Advanced MPPT Technology: Equipped with Multi-Point Power Tracking (MPPT) to optimize energy harvest from each panel string under varying environmental conditions. ● Robust Grid Compliance: Supports seamless integration with the grid, adhering to local standards and regulations. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 24 | Supply & Fixing of robust galvanized iron (GI) mounting structure for the solar panels, designed to ensure secure and efficient installation. This GI structure is crafted through a meticulous process involving the melting of iron ore and coal,followed by the removal of impurities. This results in a durable, corrosion-resistant frame that can withstand harsh environmental conditions. Engineered to withstand wind speeds of up to 180 km/h, making it suitable for various climatic conditions. ● Tilt Angle: Fixed at 22 degrees, optimizing the angle for maximum solar energy capture throughout the year. Mechanical Data: ● Coating: Hot- dip galvanized to provide superior corrosion resistance and longevity. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 25 | Electrical Cabling and Conduits Supply & Fixing of utilizing high-quality electrical cabling and conduits , a leading manufacturer renowned for its robust and reliable wiring solutions. products are known for their superior quality, durability, and compliance with international safety standards (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 26 | Supply & Fixing of DCDB (Direct Current Distribution Box): Input of Solar Panels: DCDB is connected directly to the solar panels, where it receives the DC power generated by the panels. Each string of solar panels is typically connected to a DC combiner box to consolidate the DC power output before it reaches the DCDB. Protection and Safety: DCDB includes various protective devices such as fuses, circuit breakers, surge protection devices, and isolators. These devices are essential to ensure the safety of the solar plant by preventing overcurrent, overvoltage, and short-circuits that can damage the panels or other components .Monitoring and Control: DCDB may also include monitoring and control devices such as string-level monitoring systems. These systems help detect any issues with individual strings of panels, enabling early detection and maintenance. DC to AC Inverter Connection: The DC power from the solar panels is fed into inverters, which convert it into AC power for use in the electrical grid. The DCDB facilitates the connection between the inverters and the DC source. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) |
| 27 | Earthing in Solar Photovoltaic (PV) systems is crucial for safety and system integrity. It involves connecting the system’s conductive elements to the ground, creating a path for fault currents to safely dissipate, and preventing electric shock. Solar PV Systems differ from traditional electrical systems, in that they generate direct current (DC), which is then converted to alternating current (AC) by an inverter. Key Components requires proper grounding include solar panels, inverters and lightning protection systems. (Including all material ,labour, machinery & NOC from Concern department) (with 10 years Warrenty) (For 60 kw solar power plant) Please Enable Macros to View BoQ information |