| 1 | Name of Work: Jhansi Vikas Pradhikaran Karyalay ke Main Gate ka Nirman Karya.Note :-(1)- GST Excluded on the aforesaid work. |
| 2 | Civil Work Dismantling brick work or stone work in lime or cement mortar and including stacking of materials as directed by Engineer-in-charge with in a distance of 60 mt. (200 feet). 692 SOR 2022 |
| 3 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts) and lead upto 30 m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer- in-charge upto a distance of 30 m. (100) fts) from the foundation trenches. As in item no (251) above but excavation in soil mixed with moorum/shingle/kankar requiring the use of special T&P such as pickaxes. sabbals etc (251+252 SOR2022 |
| 4 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts) and lead upto 30 m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer- in-charge upto a distance of 30 m. (100) fts) from the foundation trenches.As in item no (251) above but excavation in soil mixed with moorum/shingle/kankar requiring the use of special T&P such as pickaxes. sabbals etc for every additional 30 m. (100\") lead or part of 30 m. (100 ft.) or for every additional 1.5 m. (5 ft.) lift or part of 1.5 m. (5 ft.) (251+252+254 SOR2022 |
| 5 | Cement concrete with 4 cm (1.5\") gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T & P etc. required for proper completion of the work. 281 SOR 2022 |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 5.3 DSR 2023 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters,buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts andstruts etc. above plinth level up to floor five level, excluding cost of centering, shuttering,finishing and reinforcement :U141:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stoneaggregate 20 mm nominal size derived from natural sources 5.2.2 DSR 2023 |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 5.9.1 DSR 2023 |
| 9 | Columns, Pillars, Piers, Abutments, Posts and Struts 5.9.6 DSR 2023 |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers 5.9.5 DSR 2023 |
| 11 | Arches, domes, vaults up to 6 m span 5.9.9 DSR 2023 |
| 12 | Suspended floors, roofs, landings, balconies and access platform 5.9.3 DSR 2023 |
| 13 | Extra for additional height in centering, shuttering where ever required with adequate bracing,propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured). 5.11.1 DSR 2023 |
| 14 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up tohorizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc.and maintaining it in aserviceable condition for the required duration as approved and removing it there after . Thescaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .Theelevational area of the scaffolding shall be measured for payment purpose The payment willbe made once irrespective of duration of scaffolding Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 14.72 DSR 2023 |
| 15 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) :30 mm thick 8.14.1.5 DSR 2023 |
| 16 | Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.S. screws including drilling holes in masonry work /CC/ R.C.C. and making good etc. complete. 10.11.1 DSR 2023 |
| 17 | First class brick work in 1:4 cement and Fine sand mortar in super structure including necessary cutting and moulding of bricks as required and also- including honey comb brick work, thickness of wall is one Brick thick. 305+309+ 310 SOR 2022 |
| 18 | 12 mm Cement plaster in single coat on fair side of single or half brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80 mm. In girth and finished even and smooth. No extra for mixing any additive.(II) 1 Cement: 4 fine sand 17.58 SOR 2022 |
| 19 | Mild steel or iron work in plain work such as reinforced concrete or reinforced brick work (when not included in an over a rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastege & overlapping & hooks. 504 SOR 2022 |
| 20 | Providing & applying plaster of paris Putty of 2 mm Thickness over Plastered Surface to prepare the surface even and smooth complete. DAR 13.26 SOR 2022 |
| 21 | Finishing wall with water proofing cement paint of approved make and quality on new work with two coat to give an even shade. Including supply of all material, labour and T& P etc. required for proper completion of the work. 660+661 SOR 2022 |
| 22 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) :Red sand stone - exposed face fine dressed with rough backing.(70mm thick) 8.14.2.1 DSR 2023 |
| 23 | Supply and making Steel Collar Acrylic Letter(3D) 3mm mmA-Gradeacrylic Front Letter,With 304 Grade SS Collar and sides&10 mm WPC Back Letter.1.5 Watt Korean Led Modules for Lightning & Water Proof Water supply. MR |
| 24 | Supply and Fixing ACP BASE FRAME-2Sheets of 12x4 Stone Theme ACP of 3mm Used For making Back Frame MR |
| 25 | S/F ACRYLIC Logo with Light Size 2.5x2.5, 4mm Uv Printed Acrylic Box MR |
| 26 | Electrical Work Point Wiring- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 1.10.3 DSR 2022 (E/M) |
| 27 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X2.5 sq. mm + 1X2.5 sq. mm earth wire 1.14.2 DSR 2022 (E/M) |
| 28 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 1.14.3 DSR 2022 (E/M) |
| 29 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 1.18.2 DSR 2022 (E/M) |
| 30 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 1.21.1 DSR 2022 (E/M) |
| 31 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch 1.24.1 DSR 2022 (E/M) |
| 32 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet 1.24.4 DSR 2022 (E/M) |
| 33 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1.26 DSR 2022 (E/M) |
| 34 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) 1.27.2 DSR 2022 (E/M) |
| 35 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) 1.27.4 DSR 2022 (E/M) |
| 36 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) 1.27.5 DSR 2022 (E/M) |
| 37 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 2.10.1 DSR 2022 (E/M) |
| 38 | Supplying and fixing following rating, double pole, the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A 2.12.1 DSR 2022 (E/M) |
| 39 | Supply and fixing of 3 watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set. Confiring to IP 65 Protection complete in all respect.CAT-AAA. 1441 SOR 2018 (E/M) |
| 40 | supply and fixing of recess mounting round 15 to 18 watt LED down lighter having powder coated die cast aluminium housing with heat shink,diffuser/reflector & driver set.Complete in all respect.CAT.-AAA 1403 SOR 2018 (E/M) |
| 41 | fixing & Installation of 3 meter length 25mm width casing strip for profile light MR |
| 42 | Supply testing ,commisioning & fixing of 30 watt adapter. MR |
| 43 | Supply testing ,commisioning & fixing of 30 watt 5 meter length profile light MR |
| 44 | Supplying and fixing of focus round flood light 9 watt with IP 65 & Aluminium diecast. Goddwyn |
| 45 | BEE 5 Star rated-1200mm sweep MR Please Enable Macros to View BoQ information |