Tender For Supply, Installation, Testing And Commissioning Of 6 Kva Online Ups With Battery Bank For Sdpk Centres Under Vijnana Keralam Initiative
Tender Overview
Project Description
Tender For Supply, Installation, Testing And Commissioning Of 6 Kva Online Ups With Battery Bank For Sdpk Centres Under Vijnana Keralam Initiative , Supply, Installation, Testing And Commissioning Of 6 Kva Online Ups With Battery Bank For Sdpk Centres Under Vijnana Keralam Initiative , Ups: Ups Type: Online Double Conversion Capacity: 6 Kva / Minimum 4.8 Kw Input Voltage Range: 160V - 300V Ac Input Frequency: 50 Hz ±5% Output Voltage: 230V Ac ±1% Output Frequency: 50 Hz ±0.1% Output Power Factor: = 0.8 Efficiency: = 90% At Full Load Lcd / Led Showing Input/Output Voltage, Load %, Battery Status, Alarms Protection : Overload Protection, Short Circuit Protection, Over/Under Voltage Protection And Battery Deep Discharge Protection Cooling: Forced Air Cooling Form Factor : Tower/Industrial Grade , Battery Specifications: Battery Type: Sealed Maintenance Free (Smf), Vrla Rating: 12V, 65Ah Technology: Agm / Vrla Battery Quantity - Minimum 12 Nos(Must Support 5- 7 Hours Backup For The Specified Sdpk Lab Load) Backup Time - Minimum 5 Hours Preferably Up To 7 Hours Battery Rack : Heavy Duty Power Coated Metal Rack, Proper Ventilation And Safety Arrangement Battery Manufacturing Date Less Than 6 Months From Date Of Supply , Cabling & Accessories Battery Interconnecting Cables With Lugs Input And Output Power Cables Battery Protection Using Mcb/Fuse Earthling Provision For Ups And Battery Bank
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Feb-2026 | clarifications and modifications | Technical Bid | 10-Feb-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 6 KVA ONLINE UPS WITH BATTERY BANK FOR SDPK CENTRES UNDER VIJNANA KERALAM INITIATIVE |
| 2 | UPS:• UPS Type: Online Double Conversion• Capacity: 6 kVA / Minimum 4.8 kW • Input Voltage Range: 160V – 300V AC • Input Frequency: 50 Hz ±5%• Output Voltage: 230V AC ±1%• Output Frequency: 50 Hz ±0.1%• Output Power Factor: ≥ 0.8• Efficiency: ≥ 90% at full load• LCD / LED showing input/output voltage, load %, battery status, alarms• Protection : Overload protection, Short Circuit protection, Over/under Voltage protection and Battery deep discharge protection• Cooling: Forced air cooling• Form Factor : Tower/Industrial grade |
| 3 | Battery Specifications:• Battery Type: Sealed Maintenance Free (SMF), VRLA• Rating: 12V, 65Ah• Technology: AGM / VRLA• Battery Quantity – Minimum 12 Nos(Must support 5- 7 hours backup for the specified SDPK Lab Load)• Backup Time – Minimum 5 hours preferably up to 7 hours• Battery Rack : Heavy Duty power coated metal rack, proper ventilation and safety arrangement• Battery manufacturing date less than 6 months from date of supply |
| 4 | Cabling & Accessories• Battery interconnecting cables with Lugs• Input and output power cables• Battery protection using MCB/Fuse• Earthling provision for UPS and battery bank Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender