| 1 | Dismantiling of machine pressed precast concrete interlocking paver block of any shape, any size and laid dry or laid dry and pointed in any mortar complete all as specified and directed. |
| 2 | Laying of machine pressed precast interlocking paver block of any shape, any size (except tiles) with sand cushioning at same or other location with proper slope complete all as specified and directed. (Note :- Old sand to be used after screening & cleaning). |
| 3 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 4 | M & L for cement concrete type D-2, (1:4:8) using 40mm graded stone aggregae as in foundations, filling and mass concrete complete all as specified and directed. |
| 5 | M & L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. |
| 6 | M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and no pigment complete all as specified and directed. |
| 7 | M& L for cement concrete type B-1, (1:2:4) using 20mm graded stone aggregate as in copings, kerbs and like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 8 | M & L for preparation of old painted surfaces on brick, stone, concrete, asbestos cement or plaster surface of any description, not otherwise described, over 10cm width or girth and applying one coat of glazed lacquer hardener paint (polyurethane and acrylic polymers based anti fungal) complete all as specified and directed. |
| 9 | M & L PCC (1:3:6), type C-2, 50mm thick as in plinth protection, Surface finished fair and smooth without using extra cement complete all as specified and directed. |
| 10 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 11 | M&L Brick work using old size bricks with sub class \"B\" bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 12 | M&L Brick workexcept Bricks straightor curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 13 | Taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 14 | M&L for rendering 10mmthick in ceiling on brick work or concrete surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and directed. |
| 15 | M&L for rendering 10mm thick internal wall surfaces on fair faces of brick work or concrete in CM (1:6) complete all as specified and directed. |
| 16 | M&L for rendering 15mm thick external surfaces on brick/concrete in CM 1:4 finished even and smooth without using extra cement with WPC 3% by wt of cement.Note:-WPC measured and paid separatly. Plaster will be executed upto 15 m height and no any extra cost will be considered complete all as specified and directed. |
| 17 | Supply Only integral water proofing compound |
| 18 | M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemperas per manufacturer instruction white or tinted complete all as specified and directed. |
| 19 | M & L for preparation of new plastered/decoarated wall surfaces and applying two coats of water proof cement base paint complete all as specified and directed. |
| 20 | M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. |
| 21 | M & L for applying a thin layer of 0.50mm thick white wall care putty over newly/old plastered surface toprepare the surface even and smooth complete all as specified and directed. |
| 22 | M & L for Preparation of old decorated surfaces of walls and applying one coat of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. |
| 23 | M & L for two coat of cement base paint over a coat of primer as per manufacturer instructionincluding removal of existing treatment on existing old surfaces of walls complete all as specified and directed. |
| 24 | Dismantling Timber scantling 40 sqcm over in sectionin any descriptioncomplete all as specified and directed. |
| 25 | S&F Rolled mild steel section as in joist, chanel, angle, rafters, purlins or tee section fixed independently without connecting plates, etc (cut to ordinary length i,e within 20mm of the length indicated) of Fe-410w(Gde-E-250) quality A complete all as specified an directed |
| 26 | Dismantling plain corrugated asbestos /translucent sheet in roof covering incl ridges. complete all as specified and directed. |
| 27 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of ancolour having tensile strength of 550 Mpa and finishing with resin coat on both surfaces @ 150 gm/sqm (AZ-150) of coating as in roof covering /cladding to wall fixed with selftapping screws complete all as specified and directed. |
| 28 | Dismantling of wall and ceiling boards, any thickness including cover fillets complete all as specified and directed. |
| 29 | M & L for anodised aluminium snap grid frame work of size 600mm X 600mm for false ceiling incl hanging toplastered surfaces/iron framework using suspenders et complete all as specified and as directed. |
| 30 | S&F 4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling.complete all as specified and directed. |
| 31 | S&F in repairs4mm thick HSPC non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws as in ceiling complete all as specified and directed. |
| 32 | S & F sandwiched hollow PVC wall Lining/panelling consisting of 5mm thick Plain designer colour PVC sheet but single side prelam PVC sheet used instead of plain colour sheetinclusive of solvent cement and fixing at site on wall/PVC frame etc complete all as per specified and directed. |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 34 | M & L for 25mm thick cement concrete type B-0, (1:2:4) using 12.50mm graded stone aggregate as in levelling course complete all as specified and directed. |
| 35 | M & L for cement concrete type C-2, (1:3:6) using 40mm graded stone aggregae as in sub base etc complete. |
| 36 | M & L for high strength coloured parking vitrified tiles min thkness 12 mm for heavy loads etc laid over and including 15 mm thick bedding layer in cement mortar 1:6set, jointed and pointedwith matching colour cement and using pigmentcomplete all as specified and directed. |
| 37 | M&L for 18-20mm thick granite slab, machine cut, well polished, bedded in 15mm thick in CM 1:6 as in cooking plaforms & like and jointed with grey cement slurry and pointed with white cement(1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting, polishing and rounding of edges etc. complete all as specified and directed. |
| 38 | M&L for Marble work makrana white 18 to 20mm thick (table rubbedand polished)in steps,jambs,pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types complete all as specified and directed. |
| 39 | M & L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM (1:6) complete. |
| 40 | M&L for vitrified Ceramic tiles light shed 8 mm thick (square/ rectangular) polished, area of each tiles notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM (1:6) complete. |
| 41 | All as per ser item No 40 above but as in vertical surfacesin skirting and dado including rendering/screeding including cement mortar1:4 , 10mm thick complete all as specified and directed. |
| 42 | M & L for coloured glazed ceramic tiles in vertical surface 7mm thickexc 0.06 Sqm but not exc. 0.20 Sqm, set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in cement mortar (1:4)as backing for tiles complete all as specified and as directed. (Note : Work will be carried out as in repair of patches in lieu of existing broken flooring/wall tiles) |
| 43 | M & L Machine cut Kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) complete.(Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) |
| 44 | M & L Kota stone slab 15-18 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and incl 10mm thick rendering in cement mortar (1:4) , on fair faces of brick work or concrete surfaces as backing complete.(Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) |
| 45 | M & L for Chequered cement concrete coloured tiles 250x250x25 mm thick laid over and including 20 mm thick bedding layer in cement mortar 1:6set, jointed and pointed in cement mortar (1:3) with grey cement and using pigment as in paths etc complete all as specified and directed. |
| 46 | S&F brass CP peg set of 5 hooks incl fixing to walls, wooden shutters etc complete all as specified and directed. |
| 47 | S&F in repair 15mm Brass CP kitchen sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 48 | S&F in repairs15mm borecast copper alloy chromium plated fancy type wall mixer tapfor cold & hot with overhead shower arrangement or as required on site for existing arrangement complete all as specified and directed |
| 49 | S&F in repair white colour rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltrhoisted and fixed in position incl tank nipple, connections as required in execution for GI/CPVC pipe lineacomplete all as specified and directed. |
| 50 | S&F in repair 15mm Brass CP WHB mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 51 | S&F in repair 600mm x 450mm looking mirror 5mm thick of selected quality glass, mounted on 6mm thick commercial ply wood and fixed to wooden plugs with chromium plated brass and cup washer complete all as specified and directed. |
| 52 | S&F in repair brass chromium plated tubler towel rail 20mm dia D type, 60cm long between flanges complete all as specified and as dirceted |
| 53 | S & F in repair chromium plated soap dish fixed to wall with CP screw complete all as specified and directed. |
| 54 | S & F in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 55 | S & F as in repair brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed. |
| 56 | S & F in repair 15mm stop valves/angle valves cast copper alloy fancy type chromium plated with long shank and cup screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed all as specified and as directed |
| 57 | S&F as in repair PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and as directed. |
| 58 | S & F in repair 100mm dia steel chromium plated gratings fixed on floor trap/Nahani trap in cement mortar (1:4) complete all as specified and directed. |
| 59 | S & F in replacement LED lights fitting 1x 20W 220V, LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements,complete all as specified and as directed. |