| 1 | Supply & fixing Sub main wiring with two single core PVC insulated unsheathed cable copper conductor(FRLS-H) of size 2.5 sqmm multistrandedand one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring alongwith conduit complete all as specified and directed by Engineer-in-Charge. Note: Two runs of single core cable and one run of earthing cableand one run of PVC conduit shall be measured as one unit length. |
| 2 | Supply & fixingany type and any capacity 200 watt of LED floodlightincluding making electric connection using two runs of 1.5 sqmm single core unarmoured wire from junction boxcomplete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and erect steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) conforming to IS 2713 including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer over the exposed surface and applying two coats of black bituminous paint over the embedded portion of pole,erecting intruly vertical position complete all as specified and directed by Engineer-in-Charge. Note : Necessary excavation, earthwork, concreting and formwork shall be measured and paid separately. |
| 4 | Supply and fixing of ALL-IN-ONE smart integrated Solar street light, fully intelligent designed luminiare with built in Mono Crystalline Panel (48 Watt), Lithium Ferro Phosphate(LifeP0 4) battery, 12.8 V, 30 Ah (BIS certified) , MPPT charge controller and PIR Sensor with colour temperature 6000-6500K, 2 days autonomy with dimming, modern portable design, dust proof, waterproof with luminaire efficacy of 120 lumen/watt, LED lamp life of 50000 hours and system wattage of 30 wattcomplete all as specified and directed by Engineer-in-charge. |
| 5 | Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole)7 metre Octagonal Mild steelpole, silver color complete with Top dia 70mm, Bottom dia 135mm, 3mm thick, MS base plate 200X200X12mm and foundation bolt M20X600mm andstreet light bracket single arm suitable for LED street light fittings including drilling of holes of required size etc including taking down carefully of old unserviceable deteriorated RCC/steelpole complete all as specified and directed by Engineer-in-Charge. Note : Necessary excavation, earthwork, concreting and formwork shall be measured and paid separately. |
| 6 | Supply and fixing ofLED post top 10watt offering excellent uniform illumination and aesthetic in one go, made up of pressure Die cast aluminium body and opal PC cover IP 66 protection including 6 metre integrated decorative pole with furnish black colour painting including PCC base as per manufacturer\"s normsinstructions complete all as specified and directed by Engineer-in-Charge. Note: Necessary excavation, earthwork, concreting and formwork shall be measured and paid separately. |
| 7 | Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portions embedded under concrete, etc complete all as specified and directed by Engineer-in-Charge. Note: Necessary excavation, earthwork, concreting and formwork shall be measured and paid separately. |
| 8 | Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core, complete including disconnecting and taking out old existing unserviceable cable complete all as specified and directed by Engineer-in-Charge.Note: Necessary excavation, earthwork shall be measured and paid separately. |
| 9 | Taking out of old serviceable / unserviceable PVC under ground LT XLPE cable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etc complete all as specified and directed by Engineer-in-Charge. Note : Excavation, earthwork shall be measured and paid separately. |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cables complete all as specified and directed by Engineer-in-Charge. Note:- The Ratequoted shall deemed to be inclusive of cutting and removal of PSP Sheets wherever occurred during excavation and the same shall be staged at desired location as directed at site. |
| 11 | Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil complete all as specified and directed by Engineer-in-Charge. |
| 12 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material and labour for sub class \"B\" old size bricks well burnt as covering to under ground cables , laid dry, flat over the cables on sand cushioning with width equal to length of the brick as mechanical protection to cable, complete all as specified and directed. |
| 14 | Returning filling in soil including providing cable cushioning with riddled earth obtained from excavation,leveling watering and well ramming in layers not exceeding 25cm thick over the cushion layer complete all as specified and as directed. |
| 15 | Supply and Fixing GI tubing Medium grade 40mm dia ISI marked along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply, install, test and commission out door type cubical feeder pillar box outer shell made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm on Plain Cement Concrete nominal mix 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and backopen able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, Size of panel board- 1.0X0.9X0.5 metre, a) TPN, Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve.b) Incoming MCCB 4 pole 125 Amp 25 KA -01 Noc) Out going MCCB TP 63 Amps 16 KA - 4 Nos (d) Out going MCB TP 63 Amps 10 KA - 4Nose) Indicator lamps RYB –01 S etf) Voltmeter 0-500 volts 96 mm square flush pattern-01 No. f) Amp meter 0-200 Amps 96mm square flush pattern - 01 No Note :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694. (iii) Panel drawing shall be got approved before placing of orderfrom Engineer-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonry work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu.. |
| 17 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&L for Plain Cement Concrete 1:4:8 type D-2 nominal mix using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and directed by Engineer-in-Charge. |
| 21 | M&L for Plain Cement Concrete 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in pole foundation, coping, stay pits etc including provision of necessary form work i.e. road cuttingto achieve fair finishes surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Taking out PCC/steel tubular/octogonal LT pole or HT pole of any type complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and installation of advance maintenance free tripod ring earthing system by boring the required nos of holes of dimension 8 to 10 inch wide and length of hole should be less than approximately 2 inches of the electrode length in semi hard soil or hard soil consisting of three Nos (UL) 467-2007 or latest as well as IEC 62561listed CPRI tested Pure copper tube earth electrode designed in accordance to IS:3043(1987).The system consists of copper tube earth electrode having purity of 99.99%.There is a copper strip inside it which is pressure filledwith highly conductive crystalline mixture of metal alloys and other conductive material. Both the ends of the electrode should be permanently sealed with the extended terminal having two holes at the top for connecting the earthing system to the equipment/load. The Copper tube earth electrode should beof outer dia 50 mm,thickness of rod 01mm and length 03 mtrs tested according to IEC 62561-2 with minimum 10 years life span (the rod should be marked as per the UL certification ) including min 25 Kg/electrode of earth enhancing compound (PROCEM) NABL certified, CPRI tested eco friendely tested as per the IEC 62561-7 and needs to be considered to fill the 100 mm bored hole surrounding to the electrode. the earth enhancing compound should have restivity less than 50 ohm-meter with chemically inert to sub soil that should not pollute the environment and non corrosive to the earth electrode itself. Provision of the connector for connecting electrode with earthing conductor/strip including fastener made of stainless steel/copper/brass as directed having suitable size according to the electrode and earthing conductor dimensions. all the three earthing electrode would be separated by appropriate distance of not less than 3m and not more than 6m and connected to Each other by and including 25X3mm copper strip to make ring earth and further to be connected to the testpoint and to be buried in appropriate depth not less than 500 mm below the normal ground level and earth pit chamber of suitable size not less than 300mmX3000mmX300mm internal dimension made of FRP material complete with flush mounted, removable and lockable cover able to withstand 15KN for Each earth electrode all as directed by engineer in charge. The interconnecting conductor/copper strip shall also be covered with approximately 30 kg of earth enhancing compound for each 3 metres length of strips all to be included in quoted rate itself. The Earth pit inspection chambershould be as perIEC 62561-5 or latest and will be of 300x300x300 mm inside dimension of RCC with 50 mm thick and fine finish. The marking space should be present on RCC Cover. The chamber should have facility for making earth resistance and latest testing date by paint at the cover and previous recorded values inside the cover all as per description of engineer in charge. Note-copper strip of 7.5m length from earthing electrode to the test point and copper strip required for interconnections of rods to make rings of approximately 9.0 metre is included in the quoted rate. |
| 24 | Dismantling existing old vintage damagedglow sign board and Supply and fixing of glow signboard of over all size 2000mmX 800mm X250mm (LxHxD) made out of aluminium Equal angle of size 30mmX30mmX3mm thick of suitable length fixed on all outer corners, inside MS square hollow tube of size 25mm and provn of Aluminium Sheet of size 26 gauge 250mm width on four side of the board fixed by usingsuitable nuts/screws/washers including necessary welding where ever required with double (front and back) side acrylic sheet of size 3mm thick fixed on 75mm PVC heavy duty pipe on both side of length 1.7M erected 30cm above the ground level grouted in Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate on both side up to a depth of 60CM with a dimension of trench 300X300X600mm depth and symbol/number /alphabeatic reflective cum fluorescent stickers as sign writing letters of size along with provn of suitable size of LED tube DC light as per required lumens with required wiring inside including 2 core round connecting cable of size 2.5sqmm of suitable length connected from PVC junction box of size 100mmX100mmX40mm depth with inside 2 Nos aluminium bus bars with insulators fixed on one leg above the ground complete as per samplecomplete all as specified and directed by Engineer-in-Charge. |
| 25 | M/L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth strip of size 25 x 3 by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSRPt I.The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8TMTbar reinforcement both ways at 140 mmcentreto centrecomplete all as specified and directed by Engineer-in-Charge. |
| 26 | Taking out old solar panel & Supply and install monocrystalline solar panel rating of 100W, including suitable connecting cable to battery with GI structure fixed on groundcomplete all as specified and directed by Engineer-in-Charge. |
| 27 | Taking out battery & Supply and fix solar tall tubular 12V, 100AH ,C 10, battery with connecting terminal including suitable enclosure box for battery made out 3.15 mm thick CRCA sheet with sloping canopy on the top of box with small housing ventilation lovers on the side of the enclosure, the battery shall kept on 6mm hylam sheetcomplete all as specified and directed by Engineer-in-Charge. |
| 28 | Taking out battery charger & Supply and fix MPPT solar battery charger controller of rating 30Acomplete all as specified and directed by Engineer-in-Charge. |
| 29 | Taking out LED tube rod & Supply and fix LED DC Tube rod 9wattscomplete all as specified and directed by Engineer-in-Charge. |
| 30 | Taking out old unserviceable obstruction light from any height and supply and fixing new obstruction light of capacity 302 LED die cast aluminium housing with red polycarbonate dome for better illumination with integral drivercomplete all as specified and directed by Engineer-in-Charge. |
| 31 | Taking out unserviceable PVC wire any height and Supply & fix PVC Copper wire for 2 Core 1.5 Sqmm any height including PVC Conduit 20mm diacomplete all as specified and directed by Engineer-in-Charge. |