| 1 | M&L for preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide on surface ofMetalic poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm blue basecomplete all as specified and directed. |
| 2 | Supply and fixing in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection including taking down old unsv box complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex. |
| 3 | Supply and fixing in replacement cable three core flexible twiested copper conductor of size 1.5 Sqmm complete all as specified and directed. |
| 4 | Supply, laying and testing, in replacement XLPE cable, insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, in trenches or passing through pipe or fixed to wall / pole and duct etc, including taking down of old unserviceable cable completeall as specified and as directed. |
| 5 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 35 sq. mm, 3.5 core nominal cross section in service connections including taking down of old unserviceable cable completeall as specified and as directed. |
| 6 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 95 sq. mm, 3.5 core nominal cross section in service connections including taking down of old unserviceable cable completeall as specified and as directed. |
| 7 | M&L for DWC pipe of 50 mm dia for electrical ducting laid in trenches and jointed including necessary jointing material, tees/ union/ socket etc completeall as per manufacturer\"s instructions including taking out old pipe complete all as specified and directed. |
| 8 | M&L for DWC pipe of 63 mm dia for electrical ducting laid in trenches and jointed including necessary jointing material, tees/ union/ socket etc completeall as per manufacturer\"s instructions including taking out old pipe complete all as specified and directed. |
| 9 | M & L for Cutting & removing existing joint and supply, jointing and testing straight through Hot shrinkablecable joint including all materials and accessories suitable for 3.5 core XLPE cable of 1100 volts grade complete all as specified and as directed.(a) 16 sq mm to 50 sq mm.Make: 3M/Denson/Raychem RPG Note : Excavation and Earthwork shall be measured &paid seperately. |
| 10 | All as per here-in-above but 70 sq mm to 150 sqmm complete all as specified and directed. |
| 11 | Material and labour for replacement ofearthing completewith galvanizedearth plateelectrode in 60 cm x 60 cmx6 mm thick buried directly in ground verticallyat a depth not less than 2.25 meterbelowgroundlevel with top edgeof earth plateat depth not lessthan 1.5 mtrbelow ground level connecting to and including GI strip32 mm x 6 mmby means of GI bolts, nuts, check nuts and washerlight grade40 mm dia GI protectionpipeandconnected to equipment, GIpipe medium grade20 mmdia forwatering an includingfunnel wire mesh, RCCpitcoverand PCC 1;2:4type B-1 including Rocksalt, charcoal, excavationand earth workdisposalof surplussoil shown as plateNo 3 of SSR Part - I2009 completeall as specified and directed.Note:Theunitrate quoted shalldeemed to have included for GIprotection pipe, GIearth stripup to 7.5mtr, GI waterpipe, wiremesh , funnel , excavation, RCC pitcover complete. |
| 12 | Supplying and laying in replacement synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m completeall as specified and directed. |
| 13 | S&F in repair MCCB, 63 Amps, four pole, 16 KA, 415 volt adjustable type completeall as specified and directed. |
| 14 | S&F in repair MCCB, 100 Amps, four pole, 16 KA, 415 volt adjustable type completeall as specified and directed. |
| 15 | S&F in repair MCCB, 160 Amps, four pole, 36 KA, 415 volt adjustable type completeall as specified and directed. |
| 16 | S&F in repair MCCB, 250 Amps, four pole, 36 KA, 415 volt adjustable type completeall as specified and directed. |
| 17 | M & L for Site Clearance, cleaning away all grass, vegetation, saplings, Scrubs, brush wood, under growth roots…etcin soft/loose soil all as specified and directed |
| 18 | Excavation intrenches in soft/loose soil not exceeding 1.5 mtrdeep and not exceeding 1.5 mtrwide for laying of cables, pipes, RCC poles / stays and struts etc and getting out including trimming sides and forming levelledbottom surface all as specified and directed. |
| 19 | Returning, filling in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. |
| 20 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 21 | S&F in replacement of 60 watt LED street light, compact and aesthetic aluminium powder coated housing with precise street optics lense, IP66 fix on existing bracket and connection to existing electric network including taking down the unsv old light complete all as specified and as directed.Make:- Wipro Cat Nolr-13-671-XXX-57-XX or Bajaj/HPL/Philips/GE or equivalent. |
| 22 | S&Fin replacement of Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium housing, IP66,70W LED flood light,suitable for highlighting architectural facade and general purpose lighting including taking down the old unsv fittings. of make Havells , 50 Hz. Incl IP 65 as per existing at site.Make :-Havells, Item Description-JETAADORNFLS70WLED757SSYMTOTGor CG/Philips/HPL./Syska or equivalent. |
| 23 | Servicing of DG set (\"C\" Check) of Cap 25 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and as directed.(a) Lub oil filter.(b) Lubrication oil.(c) Fuel filter.(d) Coolent top up.Make of DG set: TATA Powerlux. |
| 24 | Supply only following parts/ Items forDG set 25 KVA:-(a) Engine oil 20W40 |
| 25 | (b) Coolant |
| 26 | ( C) Radiator servicing complete |
| 27 | (d) Controller panel of DG set |
| 28 | (e) Water Pump Assembly |
| 29 | (f) HWT Switch |
| 30 | (g) AVR of DG for 20/25 KVA capacity including with connection complete all as specified and as directed |
| 31 | (h) Fuel Retrun/Supply Pipe |
| 32 | (j) Pipe EGR & EGR valve |
| 33 | (k) V Belt |
| 34 | (l) VDO Oil Pressure sensor cum Switch 0-7 BA |
| 35 | (m) Hose pipe set |