| 1 | Excavating in trenches not exc 1.5 m wide and not exc 1.5m in depth for drains in soft/loose soils complete all as specified and as directed. |
| 2 | Excavation in trenches in soft /loose soil, n exc 1.5m wide but n exc 3.0m in depth ;for foundation etc.or for shafts well cesspit,maholes, pier holes etc.n exc 10 Sqm on plancomplete all as specified and as directed |
| 3 | Excavating over areas n exc1.5m deepand getting out in any type of soil complete all as specified and directed |
| 4 | ditto but depth exc 1.5m not exc 3m getting out in any type of soil complete all as specified and directed |
| 5 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundations, filling and mass concrete. complete all as specified and directed |
| 6 | M&L for broken bricks or brick bat loose filligs with aggregate of gauge 80 to 150mm in soakage pits,soakage well complete all as specified and directed. |
| 7 | Removing excavated material (Soils) not exc 50 m & depositing where directed at level not exc. 1.5 M above the starting point complete all as specified and as directed. |
| 8 | Returningfilling in including, spreading, levelling, watering and well ramming in layers not exc 25 cm soft/loose soils complete all as specified and as directed. |
| 9 | Demolition and breaking up drain pipes of150mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as specified. |
| 10 | Demolition and breaking up drain pipes of200mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as specified. |
| 11 | Demolition and breaking up drain pipes of300mm internal dia of bore SGSW, AC or reinforced concrete pipe set in cement mortar complete all as specified. |
| 12 | M & L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 150mm diacomplete all as specified and as directed. |
| 13 | M & L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 200mm diacomplete all as specified and as directed. |
| 14 | M & L Concrete bed to drain pipes including packing under and haunching against the sides of pipes after the air laid and tested in Cement Concrete 1:3:6 type C2 for bore of pipes 300mm diacomplete all as specified and as directed. |
| 15 | M&L for SGSW drain pipes laid in trenches of 150 mm internal diameter of pipe and jointed as specified complete all as specified and directed. |
| 16 | Supply ,layingand jointing 150mm nominal bore dia double wall corrugated (DWC) pipesclass SN4 confirming to IS-16098:2013 (Part-2) l,stiffness with and including necessary jointing materials complete all as specified and directed. |
| 17 | Supply ,layingand jointing 200mm nominal bore dia double wall corrugated (DWC) pipesclass SN4 confirming to IS-16098:2013 (Part-2) l,stiffness with and including necessary jointing materials complete all as specified and directed. |
| 18 | Supply ,layingand jointing 300mm nominal bore dia double wall corrugated (DWC) pipesclass SN4 confirming to IS-16098:2013 (Part-2) l,stiffness with and including necessary jointing materials complete all as specified and directed. |
| 19 | Demolition of cement concrete in ground floor and paving not exc 15cm thickness (below or above ground level) all as specified. |
| 20 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed. |
| 21 | Demolition ofbrickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, built in cement mortarcomplete all as specified and as directed. |
| 22 | M&L brick work with sub-class \"B\" bricks, straight or curved on plan exceeding 6 M mean radius built in CM 1:6complete all as specified and as directed. |
| 23 | Brick work with sub class \"B\" bricks in one brick thick honey comb walling ,built in cement mortar 1:4 complete all as specified and directed. |
| 24 | Taking down cement plaster of any description including racking out joints for key scrubing with water etccomplete all as specified and as directed. |
| 25 | M&L for rendering on fair faces of brick workor concrete surfaceof wall 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed( WPC shall be measured and paid separetely). |
| 26 | Demolition of cement concrete (reinforced) ofany description and in any position not otherwise specifically provided forcomplete all as specified and as directed. |
| 27 | M&L Precast cement concrete M 20 (Using 20 mm gradedstone aggregate) Type B1 in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4complete all as specified and as directed. |
| 28 | M & L for RCC (1:2:4) nominal Mix using 20mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m spancomplete all as specified and as directed. |
| 29 | M&L for RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs , landings, balconies, canopies,deck slab and in shelves and the like complete all as specified and directed. |
| 30 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 31 | M&L for mild SteelTMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete. |
| 32 | M&L for mild steel TMT bars 5 mm and over upto and including 10 mm dia in stirrups,spaces and binderscut to length bent to shape required includingcranking bending spirally for hooping for columns hooking ends and bindingwith and including mild steel wire ( annealed)not less than 0.9 mm diacomplete all as specified and directed. |
| 33 | Use & waste for form work to soffits of suspended slab suchas roof slab, floor slab , landing and similar work; not exc 200 mm thickhorizontal or sloping, finished fair and even complete all as specified and directed. |
| 34 | Use and waste of form work to faces of walls, retaining walls, abutments, parapets and staircases, railing and similar work including attached pillasters, buttresses etc vertical or to batter fair finished surface of concrete complete all as specified and directed. |
| 35 | M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed. |
| 36 | Supply only Water proofing compound |
| 37 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed. |
| 38 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or trenches ,110 mm bore complete all as specified. |
| 39 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or trenches,75 mm bore complete all as specified. |
| 40 | S&F PVC (SWR) bends any radius 110 mm bore complete all as specified. |
| 41 | S&F PVC (SWR) bends any radius 75 mm bore complete all as specified. |
| 42 | S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. |
| 43 | S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed. |
| 44 | S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 45 | S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 46 | S&F, 110mm bore PVC (SWR) branch piece, single(Single Y) equal or unequal with access door complete all as specified and directed. |
| 47 | S&F 110 mm bore PVC (SWR) vent cowlcomplete all as specified and directed. |
| 48 | S&F PVC (SWR) gully trap 125 x 110 mm setting and jointing with solvent cement complete all as specified |
| 49 | Removal of sludge from septic tanks / manholes of any size and depth and burying the sludge in pits with suitable depth & filled by earthout side the building perimeter including earth work and removal of surplus soil including dewatering of water complete all as directed. Note - Dewatering of water or mud will not be paid only sludge to be paid |
| 50 | Removal of sludge from septic tanks of any size and depth and burying the sludge in pits with suitable depth & filled by earthout side the building perimeter including earth work and removal of surplus soil including dewatering of water,Mud etc complete all as Specified and asdirected. |
| 51 | Clearing & removal of blockage, of any type in WC, bathroom, kitchen including floor/nahani traps, soil waste/vent pipes gully trap upto 1st manhole, in any situation by way of cleaning / desludging and removing foreign materials to a distance up to 50 metres to the entire satisfaction of engineer-in-charge. |
| 52 | Note:-(a) Contractor shall detail his supervisor to office of AGE B/R daily by 9.00 AM who will report to concerned JE B/R /Engineer-in-Charge to receive all complaints of entire area divided in two partsi.e. Md accn & OTM accn under this contract.(b) Contractor shall provide service providers (sweepers) separately for both the areas as per the complaints list given alongwith all requisite tools, equipments, including safely measures for attending complaint and ensure completion report by 5.00 PM same day.(c)Complaint/blockage cleared in one building in a day may be for WC, bath, kitchen, floor/nahani traps etc shall be treated as one complaint.(d) Please note that all the complaintsrelating to internal sewage (WC/bath/kitchen etc) shall be attended within same day (within 12 hour).(e) In case any complaint pertaining to inside the building (WC/bath/kitchen) is not attended by 12.00 hours. A penalty @ Rs. 100% complaint shall affected from contractor payments. |
| 53 | Cleaning of all blockages in sewer line of any type and dia (150,200,300MM)of sewer lines, manholes of any section and any depth, in any situation by way of cleaning/desludging foreign materialsm bymechanically including desludging where required and as ordered by Engr-in-Charge and keeping sewer line functional from floor traps, water closet, soil waste/vent pipe, gully trap upto final drop /outlet into septic/central sewage system terminating in other joining zone/area or into sewage well complete all as specified and directed. |
| 54 | M&L for providing 35mm thick precast cement concrete louvres and jallies, type B0 1:2:4 (12.5mm graded aggregate) measured solid,including all mouldings but excluding frame and set in cm 1:4 all as specified and directed. |
| 55 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces,complete all as specified and directed. |
| 56 | M & L for RCC precast NP 2 pipe 450 mm dia laid and tested intrenches including dismantling of old pipe of any description specified. |
| 57 | M & L for PCC (1:3:6) type C2 as in 450 mm dia cement concrete NP 2 pipe concrete bed to drain including packing under and haunching against the side of pipe after they are laid and tested all as specified. |
| 58 | Dismantling wroght iron or mild steel work of any description not oterwise provide for complete all as specified and directed. |
| 59 | M&L for broken glass coping on top of walls set in CM 1:3 including taking off and removing rubbishcomplete all asspecifiedand as directed. |
| 60 | M&L for sand cushioning to underground cable providing with a layer 8 cm before laying and 15 cm after laying, jointing and testing the cable all as specified and directed. Note:Punned thickness of sand shall be measured. |
| 61 | supply and laying the Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge. |
| 62 | Supply, fixing and connecting in repair PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5 sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed |
| 63 | Supply, fixing and connecting in repair LED street light fitting 45 Watt having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK08 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, system efficay >100lm/W,CRI >70%, THD<10%,complete all as specified and directed by the Engr - in - charge. |
| 64 | Supply, fixing and connecting in repair LED street light fitting 60 Watt having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK07 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, system efficay >100lm/W,CRI >70%, THD<10%,complete all as specified and directed by the Engr - in - charge. |
| 65 | Supply, fixing and connecting in repair LED street light fitting 70 Watt having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK07 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, system efficay >100lm/W,CRI >70%, THD<10%,complete all as specified and directed by the Engr - in - charge. |
| 66 | Supply, fixing and connecting in repair LED street light fitting 90 Watt having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK07 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, system efficay >100lm/W,CRI >70%, THD<10%,complete all as specified and directed by the Engr - in - charge. |
| 67 | Supply, fixing and connecting in repair LED street light fitting 120 Watt having LED as light source, pressure die cast alluminium housing and lens embedded PC cover having IP-66 protection, IK07 with 10kV surge Built in Surge protection device, heat sink, operating voltage range 140-270 voltage, system efficay >100lm/W,CRI >70%, THD<10%,complete all as specified and directed by the Engr - in - charge. |
| 68 | Supply, fixing and connecting in repair LED flood lights, 100 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >100 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-66, Class I complete all as specified and directed by the Engr-in-charge. |
| 69 | Supply, fixing and connecting in repair LED flood lights, 150 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >100 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-66, Class I complete all as specified and directed by the Engr-in-charge. |
| 70 | Supply, fixing and connecting in repair LED flood lights, 200 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >100 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-66, Class I complete all as specified and directed by the Engr-in-charge. |
| 71 | Supply, fixing and connecting in repair LED flood lights, 300 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >100 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-66, Class I complete all as specified and directed by the Engr-in-charge. |
| 72 | Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level.Required illumination level for switching on is < 30 lux and for switching off > 10 lux.The sensor should also have part night operation facility for 4 - 12 hours.The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted hensel enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-66,The circuit should be suitable enough to take 8 KW single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Ampsconforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts completeincl taking down of existing arrangementcomplete all as specified and as directed. |
| 73 | Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level.Required illumination level for switching on is < 30 lux and for switching off > 10 lux.The sensor should also have part night operation facility for 4 - 12 hours.The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted hensel enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-66,The circuit should be suitable enough to take 15 KW Three phase load with contactor 32 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps per phaseconforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete all as specified and as directed. |
| 74 | Supply,laying or fixing or passing through pipecommissioning and testing of PVC XLPE insulated, armouredheavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 10 SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately under relevant items. |
| 75 | Supply,laying or fixing or passing through pipecommissioning and testing of PVC XLPE insulated, armouredheavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 16 SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately under relevant items. |
| 76 | Supply,laying or fixing or passing through pipecommissioning and testing of PVC XLPE insulated, armouredheavy duty, electric cable with aluminium conductor, 1100 volts grade, multi -stranded of SIZE 25 SQMM 4 CORE including suitable size lugs including taking out /dismantling of existing cable.Note:- Excavation & earth work, sand cushioning, bricks protection & GIpipe where required shall be measured & paid separately under relevant items. |
| 77 | Trimming of tree branches Clearing of LT/HT line 4 mtr all around by cutting tree branches at ground level of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr in charge. |
| 78 | Supply and fixjunction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm, 5 way having terminals for termination of cable with necessary nuts and bolts , including -02 Nos polycarbonate cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any typeall as directed. |
| 79 | S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & boltsfor protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16). |
| 80 | Material and labour for painting to steel tubular pole/Rail Pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and yellow/red synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/copingcomplete all as specified and directed by Engr in charge |
| 81 | Material and labour for painting to PCC pole of HT/ LT over head line and all MS clamps, cross arm work on poles and applying Two Coats of Exterior Emulsion paint (weather coat) including necessary preparation of surfaces and painting of alternate strip with black and yellow synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/copingcomplete all as specified and directed by Engr in charge |
| 82 | Supply, laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. allas specified and directed by Engr in Charge.of size 50 mm outer dia and 38 mm inner dia. |
| 83 | S&F, in replacement, GI pipe bracket, made out of GI pipe 40mm dia light grade 1.5mtr long bent to the shape 120 degrees angle all as per site requirement including MS clamps made of FI 50x6mm complete with nuts, bolts & washer as per requirement for mounting fittings complete allas specified and directed. |
| 84 | Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq.mm 2 core nominal cross section in service connections. |
| 85 | M&L for GI Tubes in repair of following size, medium grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed. |
| 86 | (a) 40 mm bore |
| 87 | (b) 50 mm bore |
| 88 | Repair and maintenance of street light / perimeter light / security light / Garden lights/ flood light fitting HPSV/LED, any type/make installed on LT / HT poles, building, by means of replacing any unserviceable parts as and when required complete with labour including taking down,dismantling, re-assembling and re-fixing the fitting at its original location with proper alignment and making good all defects including replacing of nuts/bolts/PVC connections etc complete all as specified and directed. |
| 89 | Taking down old unsv street light/flood light any type any wattage complete allas specified and directed. |
| 90 | Schedule of credit amount of Rs.93625.00 to be deducted during AOC |