| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding including backing and removing the rubbish off the premises complete all as specified and directed. |
| 2 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc, set and jointed in neat cement slurry, laid over and including 15mm thick screed bed or bedding layer in CM (1:6) and pointed in whiter or colored cement to match the shade of tile complete all as specified and directed. |
| 3 | M&L for glazed ceramic coloured tiles 300X 450 X 7 mm thick as on cup board vertical surface of wall such as skirting, dice, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in white or colored cement to match the surface of tile fixed over and including 10mm thick backing coat/ rendering in CM (1:4) complete all as specified and directed. |
| 4 | Cutting holes exc. half brick thick but not exc one brick in brick thick walls built in CM or cement lime mortar & stone walls built in lime mortar for inserting holdfasts & making good dismantled portion in CM(1:3) or PCC(1:2:4) type B-1 as required complete all as specified and directed. |
| 5 | Taking up or down 20 mm bore steel tubing and connections complete and removing RM out of defense land. |
| 6 | S&F 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed. |
| 7 | Refixing old steel tubing, 20 mm bore, and connections with new or old position and new fittings (Walls, ceiling, floors, etc.) complete all as specified and directed.Note:- Old steel tubes obtained from item No. 5 above shall be used under this item. |
| 8 | S&F 15 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed. |
| 9 | S&F Bib taps cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule all complete as specified and as dierected. (Make ESSCO/Marc/Cera). |
| 10 | S&F Stop valves 15 mm bore, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified |
| 11 | Taking down cement plaster on wall & ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed. |
| 12 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound with weight of cement as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note: WPC shall be measured and paid separately against respective item). |
| 13 | Supply only liquid water proofing compound conforming to IS: 2645 1975 Kg specification complete all as specified and as directed (Make: CICO No- 1/SIKA/ACCO PROOF PIDIPROOF LW+). |
| 14 | M&L for 15mm thick rendering in cement mortar 1:6 on other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 15 | M&L for preparing newly plastered surfaces/ applied putty surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 16 | M&L for preparation of old decorated wall surface by washing down, rubbing down and stopping of distempered and painted surface and including applying one coat of oil bound distemper over Chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and as directed. |
| 17 | M&L for complete removal of existing treatment and finishing the walls with Acrylic smooth exterior paint of required shade: (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 220 Kg/ 10 sqm).Make : Asian Apex Ultima/Berger weather coat long life 10. |
| 18 | M&L for preparing new plastered surfaces of walls and finishing the walls with Acrylic smooth exterior paint of required shade: New work (Two or more coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm).Make : Asian Apex Ultima/Berger weather coat long life 10. |
| 19 | Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 20 | M&L for PCC as in pedestal, roof kerbs of mud stops, rounded or chamfered on edges type B1 (1:2:4) using 20 mm graded crushed stone aggregate incl form work in isolated location complete all as specified and directed. |
| 21 | Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 22 | Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in any type soil complete all as specified and as directed. |
| 23 | M&L for PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) in fdn filling in and mass concrete complete all as specified and as directed. |
| 24 | M&L for RCC (1:1.5:3) type A1, M-20 (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified |
| 25 | M&L for RCC (1:1.5:3) type A1, M-20 (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified. |
| 26 | M&L for RCC (1:1.5:3) type A1, M-20 (using 20 mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified. |
| 27 | M&L for RCC (1:1.5:3) type A1, M-20 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified. |
| 28 | M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 29 | Ditto all as per serial item No. 28.00 described here-in-before, but TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders |
| 30 | Use and waste of formwork to flat rough finished sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 31 | Use and waste of formwork to flat rough finished sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 32 | Use and waste of formwork to square, rectangular or plougonal rough finished side surfaces of pillars, posts, struts, piers, columns complete all as specified and as directed. |
| 33 | M&L for brickwork with burnt clay flyash old size bricks, straight or curved on plan exc 6m mean radius built in cement mortor 1:6 complete all as specified and as directed. |
| 34 | M&L for brickwork with burnt clay flyash old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as directed. |
| 35 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat concrete surfaces complete all as specified and directed. |
| 36 | M&L for rendering 20mm thick in two layers (10mm +10mm) on fair faces of brick work or concrete surfaces in cemant mortar (1:4) mixed with liquid water proofing compound as per manufacturer\"s instructions in top layer on wall surface and finishing even and fair complete all as specified and directed.(Note: WPC shall be measured and paid separately against respective item). |
| 37 | M&L for preparing new plastered surfaces of wall with wall care putty (average thickness 1mm) and applying two coat of distemper oil emulsion over a coat of suitable primer complete all as specified and as directed. |
| 38 | M&L for preparation of new plaster surfaces of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 39 | M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 40 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 41 | M&L for providing 100mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed. |
| 42 | M&L for providing 40mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed. |
| 43 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification & drawing complete all as specified and directed. |
| 44 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face, in frame at site as per specification & drawing complete all as specified and directed. |
| 45 | S&F Stainless steel butt hinges medium weight 100mm size for PVC door complete all as specified and directed. |
| 46 | S&F Aluminium anodized barrel tower bolts, extruded section 200mm long complete all as specified and directed. |
| 47 | S&F Aluminium anodized handles, D type, 150mm size complete all as specified and directed. |
| 48 | S&F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed. |
| 49 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 50 | M&L for PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection complete all as specified and as directed. |
| 51 | S&F 4 mm thick sheet glass frosted, ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and as directed. |
| 52 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer including preparation on steel surfaces of any description over 10 cm width or girth complete all as specified and as directed. |
| 53 | S&F vitreous china squatting pan \"Orissa\" pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) with \"P\" or \"S\" trap from or back inlet etc including connection to trap and flushing pipe and provision of lime concrete bedding complete all as specified and as directed. |
| 54 | S&F 10 litres cap PVC low level valve less symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and flushing pipe, complete all as specified and as directed. |
| 55 | S&F Vitreous China wash basin pedestal pattern, white, flat back size 580x450 mmincluding cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe including brackets, complete all as specified and as directed. |
| 56 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinals gainst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 57 | S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed. |
| 58 | S&F 15 mm dia PVC connection 450 mm long, complete all as specified and as directed. |
| 59 | S&F 32mm bore waste coupling of PTMT (half of full threaded) complete all as specified and as directed. |
| 60 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 61 | S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed. |
| 62 | S&F 15mm bore Bib taps, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 63 | S&F 15 mm bore stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. |
| 64 | S&F towel rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) complete all as specified and as directed. |
| 65 | S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 66 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed. |
| 67 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 68 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 69 | S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 70 | S&F 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed. |
| 71 | S&F PVC (SWR) bends with access door of 110mm bore any radius complete all as specified and as directed. |
| 72 | S&F 1000 ltr Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) triple layered hoisted and fixed in position complete all as specified in SSR Part Iand as directed. |
| 73 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 74 | Removing excavated material (soil) n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified & directed |
| 75 | M&L for screed bed or bedding layer 15 mm thick in CM (1:4) mixed with WPC as per manufacturer instruction for laying of APP membrane complete all asdirected. |
| 76 | M&L for bituminous primer @ 0.50 Kg/ Sqm over the cementplaster including preparation of surfaces as per manufacturers instruction complete all as specified andas directed. |
| 77 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed. |
| 78 | M&L for finishing the Bituminous surface with two coats of aluminium paint @ 0.15 Ltr/sqm for each coat as per manufactures specifications and under strict supervision of manufactuer\"s technical representative complete in all respects as directed. |
| 79 | M&L for concrete bed to drain pipe, 200 mm bore pipe including packing and under hunching against the sides of pipe after they are laid and tested in PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggreagate) complete all as specified and directed. |
| 80 | S&F 200mm bore Salt-glazed stoneware drain pipes laid in trenches and jointed in CM (1:1) complete all as specified and as directed. |
| 81 | M&L for 75 mm thick cement concrete (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in path /steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete all as specified and as directed. |
| 82 | M&L for fine aggregate (sand) spreading and levelling in layer n exc 50mm thick under paver block for cushioning complete all as specified and as directed. |
| 83 | M&L for chemically treated machine pressed precast concrete coloured interlocking paver block with Grey cement and no pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade complete all as specified and as directed. |
| 84 | M&L for PCC (1:2:4) type B1, (using 20 mm graded crushed stone aggregate) as in footpath coping /benching to sides of foot pathfininished fair and even etc complete all as specified and direected. |
| 85 | M&L for kitchen cabinet made up of 12mm thick ply wood fixing with 0.9mm thick coloured decorative lamination on both faces including necessary adhesives, leapings, fittings and fixtures etc complete all as specified and directed. |
| 86 | M&L for kitchen cabinet (shutters) made up of 18-19mm thick ply wood fixing with 0.9mm thick coloured decorative lamination on both faces including necessary adhesives, leaping, fittings and fixtures etc complete all as specified and directed. |
| 87 | S&F stainless steel hydraulic hinges, closing concealed etc complete all as specified and directed. |
| 88 | S&F Brass Locks, cupboard, grade I, size 50 mm four levers complete all as specified and directed. |
| 89 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, brightfinished complete all as specified and directed. |
| 90 | S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in complete all as specified and directed. |
| 91 | S&F 100 mm long Brass handles, cast type, polished bright complete all as specified anddirected. |
| 92 | M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but n. exc. 0.38 Sqm, in floors etc, set and jointed in neat cement slurry, laid over and including 15mm thick screed bed or bedding layer in CM (1:6) and pointed in whiter or colored cement to match the shade of tile complete all as specified and directed. |
| 93 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement screed bed (1:4)including rounded the exposed surfaces of granite complete all as specified. |
| 94 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified |
| 95 | S&F expanded metal welded steel wire fabric complete to wood or steel member weight n.exc 4 kg per sqm complete all as specified and directed |
| 96 | M&L for point wiring for one light /fan point complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated, IS 694 unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coading drawn through and including non-metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of Gl sheet steel not less than 1.22 mm thick for boxes duly painted with anticorrosive paint, concealed in walls with bakelite/ plastic laminated sheet top cover fixed with cadmium plated iron screws for housing swithes, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sunken for boxes and macking good to the distrubed surfaces of wall/ floor and matching with existing specifications all as specified and as directed. |
| 97 | Ditto all as per serial item No 96 described here-in-before but for One socket outlet 5/6 amps point on the independent board. |
| 98 | S&F Switch piano type flush 6 Amp Single pole one way (ISI Marked) complete all as specified and directed |
| 99 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed. |
| 100 | S&F LED Bulk Head lights fitting 1x 9/10W, 220V AC integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories internally prewired and connecting up with complete all as specified. |
| 101 | S&F LED lights fitting 1x 10W, 220V AC decorative box type with driver, IP 20, class I, wall/ surface mounted, integrated type with extruded aluminum housing integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with all accessories internally prewired and connecting up with complete all as specified, |
| 102 | S&F Exhaust fan, steel body AC single Phase, 230V of size 300mm sweep with blades, frame and louvers including flexible copper cable 3 core from ceiling rose to fan complete all as specified and as directed. |
| 103 | S&F ceiling rose surface backelite 65x50mm two to three terminal (ISI marked) complete all as specified and as directed. |
| 104 | S&F MCB SPN amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) current carrying capacity 32 Amps in the MCB DB complete with connection testing and commissioning, all as specified and directed. |
| 105 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed. |
| 106 | S&F MCB DB confirming to IP 43-IK 09 with acrylic door, 4 way double door complete with all connections-Phase, Neutral and Earthing bar and making good the disturbed surfaces complete all as specified and directed. |
| 107 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less then 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level connecting to the galvanized iron earth lead 4mm dia, by means of bolts, nuts, check nuts and washer of galvanized iron and 4mm dia Gl earth wire protected by provision of Gl medium grade pipe 15mm upto 7.5 mtr bore including provision of concrete pit in PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregates) 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/ sqm) and frame of angle iron 25 x 25 x 3mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of bronze/Gun metal with fixing arrangements, funnel, wire mesh and excavation /earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 108 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trenchcomplete all as specified and directed. |
| 109 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed.Note:- Punned down thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I |
| 110 | Supply laying & testing cable XLPE insulated, screened, PVC bedded, galvanisedsteel striporwire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, (Earthed), grade cross sectional area 6 sqmm, 2 core complete all as specified and directed. |
| 111 | M&L for laying of GI pipe light grade across road for cable protection complete of size 40mm dia complete all as directed. |
| 112 | M&L for horizontal boring across the existing road without disturbing the road surface for inserting Gl pipe complete all as specified and directed. Note:- (i) Removal of surplus soil shall be deemed to be included in the unit Rate. (ii) Gl pipe will be measured and paid separately under relevant item. |
| 113 | Supply and layingin trenches GI water Tubing medium gradeof 25 mm dia including all fittings such as sockets, bends, elbows, Union etc. complete all as specified and as directed. |
| 114 | S&F stop valves 25mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 115 | Cutting of existing GI pipe of dia 25/ 50/ 80 mm and inserting ofTee in existing pipe for connecting new pipe complete all as specified and as directed. |
| 116 | S&F Exhaust fan, plastic body AC single phase, 230 V of size 250 mm sweep with blades and frames and louvers including necessery fixing arrangement for fixing plastic body exhaust fan on existing window frame work or as required at site complete all as specified and as directed. |
| 117 | M&L for throughout cutting of toilets brick wall for fixing suitable size of exhaust fan to remove air from room, adjusting the aluminium frame and repairs to broken wall as required for fixing exhaust fan and making good to disturbed surface of wall complete all to match with existing wall complete all as specified and as directed. |
| 118 | Supply, installation, commissioning of Glass Top Deep Freezer of minimum capacity 300 ltrs single phase 240 volt, 50 Hz complete all as specified and directed.The following Technical specifications are as under:-(i) No of doors : two (ii) Position of door : Top opening (iii) Door type : Hinged (iv) Air tight : Yes (v) Wheels : Yes (vi) Visibility of storage : Yes (vii) Type of insulation : Glass wool (viii) Method of defrosting : Frost type (ix) Type of cooling : Direct (x) Locking system : Yes (xi) Material of chamber : Stainless steel (xii) Door material : Glass (xiii) Cooling coil material : Cooper (xiv) Temperature controller : Yes (xv) On/off switch : Yes (xvi) Audio alarm visual alarm display : Yes (xvii) Gross volume :300 Ltrs (xviii) Insulation Thickness : 60mm (xix) Refrigerant : R134a (xx) Compressor : DC Compressor (xxi) Voltage : Single phase 230 V, 50 Hz (xxii) Temperature range <-18°C |
| 119 | Supply installation, commissioning and testing of Visi Cooler 300 Ltr cap, 5 Star Rated, single door suitable to operate on 230V, AC, SP, 50Hz with following specification complete all as specified and as directed Make : Blue Star Model VC325 or equivalent in Voltas, Rockwell or Celfrost. (a) Cap : 300Ltrs (b) No of Door : Single Door (c) Defrost System type : Frost free (d) Refrigerant ; R-600A/ R134a (e) Door Material : Glass (f) Shelf Type : Adjustable |
| 120 | M&L for concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sqmm + 1 x 2.5 sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits &making good to walls, floors etc completeall as specified and as directed. NOTE: Two runs of 4 sqmm conductor for main and one run of 2.5 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. |
| 121 | S&F MCB distribution boards (DBs) with sheet metal enclosure, single door, IP 43 protection, 240 Volts, 2 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/ other surface complete all as specified and as directed. |
| 122 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with as specified and as directed. |
| 123 | S&F switch socket combination 3/6pin 15 Amps, 240V flush type complete all as specified and directed |