| 1 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including allquoins, arches, pillars, etc, but excluding ashlars facings, dressed stonework and precast concrete articles, complete all as specified and as directed . |
| 2 | M&L for brickwork with subclass ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6.0mtrs mean radius built in cement mortar 1:6, complete all as specified and as directed . |
| 3 | All as per item No 2 above but except brick. |
| 4 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed . |
| 5 | M&L for rendering 15mm thick, on fair faces of brick or concrete surfaces, in cement mortar 1:4, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed . |
| 6 | M&L for rendering 10 mm thick, on fair surface of brick or concrete surfaces, in cement mortar 1:6, rendering is to be finished even and smooth (without using extra cement), complete all as specified and as directed . |
| 7 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a primer coat of chalk whitening, complete all as specified and as directed . |
| 8 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and as directed. |
| 9 | M&L for preparation of old/ decorated plastered or unplastered surfaces of walls and applying one coat of oil bound distemper (different colour), complete all as specified and as directed . |
| 10 | M & L for complete removal existing treatment from old surface of walls and applying two coats of exterior emulsion paint (Apex Ultima or equivalent), over one coat of alkali resistant primer including preparation of old surfaces, complete all as specified and as directed . |
| 11 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level), including cleaning,removal and disposal of rubbish/ waste materials from premises, complete all as specified and as directed . |
| 12 | M&L for plain cement concrete 1:3:6, type C-2 using 40 mm graded crushed stone aggregate as in surface chanel and drains, beds, complete all as specified and as directed . |
| 13 | Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and as directed . |
| 14 | Dismantling of floor, hearth or wall tiling including cement mortar bedding/backing etc, including all type of tiles irrespective of size and removal of debris outside the MoD land, complete all as specified and as directed . |
| 15 | M&L for 75 mm thickplain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in sub bases of floors and pavings, complete all as specified and as directed . |
| 16 | M&L for machine pressed precast concrete interlocking paver block of any size and shape (red and yellow colour only) confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and no pigment complete all as specified and directed |
| 17 | M&L for machine pressed precast concrete interlocking paver block of any size and shape (red and yellow colour only) confirming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and no pigment, complete all as specified and directed. |
| 18 | M&L for 25mm thick sand filling under floor or in foundations or in floors including watering and consolidation, complete all as specified and as directed . |
| 19 | M&L for providing cement concrete type B1 (1:2:4), cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed. |
| 20 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete including necessary earth work, complete all as specified and directed. |
| 21 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including takingout embedded portion and making good disturbed ground posts embedded in concrete, complete all as specified and directed. |
| 22 | M&L for providing plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate in) foundations, filling and mass concrete, complete all as specifed and as directed . |
| 23 | S&F MS works as in fencing posts and struts including cutting tops to bottom shape as directed, drilling holes notching for wire etc flat iron fillets for securing razor wire etc incl all drilling bolting riveting etc and similar works conforming to FE 290 gde E-165, complete all as specified and directed. |
| 24 | M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed . |
| 25 | M&L for preparation of old painted steel surfaces of any description except roof top, not otherwise described, over 10cm width or girth including and applying one coat of synthetic enamel paint, complete all as specified and as directed . |
| 26 | Supply only chain link fencing MS galvanised fencing, any size or type, complete all as specified and directed.(Note - Dia of main bar 4mm and cross bar 4mm) |
| 27 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts etc including provission of binding wire and fixing with MS angle iron fencing posts including taking down old rusted/damaged chain link fencing , complete all as specified and directed. |
| 28 | S & F of 10 mm dia 50mm length Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, complete all as specified and directed. |
| 29 | M&L for galvanised, 2-strand, steel barbed wire 2.24 mm dia barbed with 2.0 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), including taking down existing rusted/damaged barbed wire complete all as specified and as directed . |
| 30 | M&L for Preparation of old plastered or unplastered surfaces of walls and applying one coat of cement based paint, including curing of cement base paint as specifed and as direted. |
| 31 | M&L Preparation of old/ decorated, un-decorated, plastered or unplastered surfaces of walls and applying two coat of cement based paint, complete all as specified and as directed . |
| 32 | M&L Mild steel galvanised concertina coil fencing with punched tape concertina coil of any dia as per site requirement, 10 metre openable length (total length 142 mtrs), having 50 Nos. rounds per 6.0 metre length, spring core wire (2.5 mm dia galvanised wire) of high tensile strength not less than 400-450 gm/ Sqmm with tape (0.52mm thick) and weight 2.0 Kg/metre and fixing the same with existing Y-shaped angle iron placed 2.0mtrs apart and with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with G.I. staple sand, 125 to 127 Nos. of G.I. clips in one coil, to retain horizontal, including necessary nuts and bolts, including taking down existing rusted/damaged concertina coil , complete all as specified and directed. |
| 33 | Taking down chowkats or frames not exc 1.5 Sqm each with shutters (without taking off shutters from the frames). |
| 34 | Factory made steel window, box type, using ERW hollow \"P\" section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and glass sheet 3.0mm thick, 4mm thick frosted glass jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD/1517/15, sheet No- 1/3 to 3/3 and as directed . Note :- Cost of all items/elements eleborated in the specification and in Drawing shall be deemed to inlcude in quoted rate. |
| 35 | Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10cm width or girth including and applying two coats of synthetic enamel paint over one coat of zinc chrome/ red oxide primer, complete all as specified and as directed . |
| 36 | M&L for plain cement concrete 1:3:6 type C-0 (using 12.5 mm graded stone aggregate) as in filling of pressed steel frame, hold fast , complete all as specified and directed. |
| 37 | Sheet glass, 3.0mm thick, ordinary quality and glazing with oil putty or with wooden beadings, fixing in square not exceeding 0.50 Sqm in each pane including hacking out old broken glass fo any description, complete all as specified and as directed . |
| 38 | Dismantling of mild steel work of any description, complete all as specified and as directed. |
| 39 | Dismantling of Timber scantling 40 sq.cm and over in section, in any position, complete all as specified and as directed. |
| 40 | S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixedwithangle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed . |
| 41 | Fixing only Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixedwithangle cleats or other connecting plates, conforming to Fe-410 (Gde-E-250) quality-B, complete all as specified and as directed . |
| 42 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed . |
| 43 | S&F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed . |
| 44 | Fixing only Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed . |
| 45 | S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and as directed . |
| 46 | Dismantlingof wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed . |
| 47 | S&F in repair Non Asbestos Ceiling board of 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including anodised aluminium snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 605x605mm, for false ceiling all as specified, and hangers 6mm dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 4.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed . |
| 48 | Fixing only Ceiling board of 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including anodised aluminium snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 605x605mm, for false ceiling all as specified, and hangers 6mm dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 4.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long, complete all as specified and as directed . |