| Sl. No. | Item Description |
| 1 | M&Lfor painting of pipe lines with two coat of synthetic enamell paint as per colour code after cleaning and removing existing dust and dirt on existing painted surfaces complete all as specified and as directed by Engineer-in-Charge. of 100 to 150mm bore horizontal Note:- The rate for scafolding etc deemed to be included in the quoted rates. |
| 2 | Supply only water testing Kit with all accessories, samples in tubes from 0.1 ppm to 5 ppm from reputed manufacturer complete all as specified. |
| 3 | Supply only Orthotollidine solution for water testing, in 500 ml bottles complete all as speicified. |
| 4 | Supply only PH testing Kit with all accessories for swimming pool water from reputed manufacturer complete all as specified. |
| 5 | Collection of water sample from the ETP of Aakash Vihar area(one sample of Raw sewage and one sample of treated water) and STP of Vijay Vihar area(one sample of raw sewage and one sample of treated water),in total four samples and testing of the same (bacteriological and chemical analysis)from the UP Jal Sansthanor any other Govt. recognized laband submission ofreport to the department complete all as specified and directed.) |
| 6 | Supply & Installed in repair Float Switch device atDOL Starter for autoand manualoperation of sewage Pump suitable for 7.5 HP , 3 phase motor complete all as specified and directed. |
| 7 | S&F in repair of PVC Hose pipe 50mm dia complete all as specified and directed. |
| 8 | S&F in repair Nylon rope 25mm dia suitable for suction sweeper complete all as specified and directed. |
| 9 | Material and Labour for taking out duly dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity 12.5 HP from ETP plantat any location and shifting the same to contractor\"s workshop for repair and re-installation/refixing the same at its original position and and commissioningtesting complete all as specified and directed at site. |
| 10 | M&L for Cutting out the existing winding of the motor of capacity upto 20 HP, opening of winding and re-winding of motor with same size of rewinding with super enamelled copper winding wire including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection to made functional complete all as specified and directed. |
| 11 | Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected. |
| 12 | Repairing of pump shaft by depositing metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed. |
| 13 | Supply and fixing in repair gun metal/stainless steel bush of pump shaft suitable for 12.5 HP capacity complete all as specified and directed. |
| 14 | Supply and fixing in repair driven end bearing of blower shaftsuitable for 12.5 HP capacity complete all as specified and directed. |
| 15 | Supply and fixing in repair end bearing of blower shaft suitable for 12.5 HP capacity complete all as specified and directed. |
| 16 | Supply and fixing gland and packing suitable for 12.5 HP capacity complete all as specified and directed. |
| 17 | Supply and fixing coupling with studs between motor & air blower suitable for 12.5 HP capacity complete all as speicifed and directed. |
| 18 | Supply and fixing in replacement suction air filter suitable for 12.5 HP capacity complete all as specified and directed. |
| 19 | Supply and fixing in replacement of suction silencer suitable for 12.5 HP capacity complete all as specified and directed. |
| 20 | Supply and fixing Neck ring suitable for 12.5 HP capacity complete all as specified and directed. |
| 21 | Supply and fixing bearing of motor shaft suitable for 12.5 HP capacity complete all as specified and directed. |
| 22 | Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity 7.5 HP fromplantat any location and shifting the same to contractor\"s workshop for repair and re-installation/refixing the same at its original site and testing complete all as specified and directed at site. |
| 23 | Cutting out the existing winding of the motor capacity of 7.5HP, opening of winding, re-winding of motor with same size of wire with super enamelled copper winding wire including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection and made functional the motor complete all as specified and directed. |
| 24 | Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 5.0 HP fromplantat any location and shifting the same to contractor\"s workshop for repair and re-installation/refixing the same at its original after made functionalsite and testing complete all as specified and directed by EIC . |
| 25 | Cutting out the existing winding of the motor of capacity upto 5 HP, opening of winding, re-winding of motor with same size of rewinding with super enamelled copper winding wire including tapping, varnishing, baking and furnishing with the insulating sleeve and making connection and made functional the motor complete all as specified and directed. |
| 26 | M & Lfor taking out unserviceablenon clog submersible type raw effluent sewage lifting Submersible pump set of capacity upto 10 HP of rating 3 phase 440 Volts, from raw sewage collection sump/well ofplant well upto 18 mtr depth,forcleaning of muds , overhauling, Oiling,Greasing and servicingby Opening of all parts , bush ,bearing , rotor ,drum , bearing of motor shaft ,Neck ring, coupling with studs between motor & all other parts and re-assemble the same after greasing , oiling of and shifting the same to authorised workshop for repair , testing and re-installation/Re-fixing/lowering in the sewage sump complete all as specified all as directed by EIC.( Note : -( i ) Parts renewed shall be measured and paid separately under appropriate items ) (ii) Overhauling and servicing of non clog submersible Pump should be carried out by Auth company or dealer Which is specialist of above |
| 27 | Attend the day to day complaint of non functing part to Air Blower , Air Blower Motor ,non clog submersible Pump, motorof any size ,type ,capacity and all connected parts Note : -( i ) Parts renewed shall be measured and paid separately under appropriate items.(ii) Complaint Should be attend immediately within two hrs & Rectified wiithin the same day at the earliest without effecting of service .) |
| 28 | Attend the day to day sewage complaint related leakege , choke , replacement of any part , with cutting ,jointing and any other work of GI Pipe ,MS Pipe , PVC Pipe for any size ,type ,capacity and any location rectified the same all as directed by EIC.Note : -( i ) Parts renewed shall be measured and paid separately under appropriate items )(ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .) |
| 29 | Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from course bar screen including all chamber of equilasation tank upto depth of 15 Mtr any capacity from STP as per direction by EIC. |
| 30 | Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Fine bar screen ,Oil & Grease Chamberwithwaterpressure, bleaching powder etc from STP complete with all as specified & direction by EIC . |
| 31 | Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from MBBR I & II Chamber withwaterpressure, bleaching powder etc complete with all as specified & direction by EIC . |
| 32 | Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Tube Setteler Chamber withwaterpressure, bleaching powder etc from STP complete with all as specified & direction by EIC . |
| 33 | Supply and fix in repairPlastic Media MBBR (Media) as per existing size & specification of IS for STP anddirection by EIC . |
| 34 | Supply and fix in repair PAC media in tube settler tank of STP as per existing specified size |
| 35 | Replacement of sand filter media of sludge drying bed of STP as per specification laid specification of IS , as per direction by EIC . |
| 36 | Material and Labour for taking out unserviceable/burnt raw non clog submersible type raw effluent sewage lifting Submersible pump set of capacity 10 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of ETP/Sewage plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump after repair and made functional complete all as specified and directed. (Parts renewed shall be measured and paid separately under appropriate items) listed here below :- |
| 37 | Cutting out the existing winding of stator of submersible motor of 10 HP of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed. |
| 38 | M&L for Straightening of the slots of stator of submersible motorof 10 HP of any make complete all as specified and directed. |
| 39 | Supply and fixing in repair thrust bearing block complete of submersible pumpof 10 HP of any make complete all as specified and directed. |
| 40 | Supply and fixing in repair gun metal bushes for submersible motorof 10 HP as per manufacturer\"s design and specification. |
| 41 | Supply and fixing in repair of sand guard of submersible motor10 HPcomplete all as specified and directed. |
| 42 | Supply and fixing in repair of bronze metal impellars suitable for 10 HP capacitycomplete all as specified and directed. |
| 43 | Supply and fixing in repair of shaft sleeve suitable for 10 HP capacity complete all as specified and directed. |
| 44 | Supply and fixing in repair of set of gasket and O-ring suitable for 10 HP capacity |
| 45 | Supply and fixing in repairof Mechanical seal motor end suitable for 10 HP capacity |
| 46 | Supply and fixing in repair of Mechanical seal pump end suitable for 10 HP capacity |
| 47 | Supply and fixing in repair deep groove ball bearing motor side suitable for 10 HP capacity |
| 48 | Supply and fixing in repair groove ball bearing pump sidesuitable for 10 HP capacity |
| 49 | Supply and fixing in repair pump casing suitable for 10 HP capacity |
| 50 | Supply and fixing in repair of intermediate casing suitable for 10 HP capacity |
| 51 | Supply and fixing in repair in repair of bearing housing suitable for 10 HP capacity |
| 52 | Supply and fixing in repair of bearing cover suitable for 10 HP capacity |
| 53 | Supply and fixing in repair of shaft protection sleeve suitable for 10 HP capacity |
| 54 | Supply and fixing in repair of bowl, cast iron suitable for 10 HP capacity |
| 55 | Supply and fixing in repair of bearing sleeve suitable for 10 HP capacity |
| 56 | Supply and fixing in repair of rotor suitable for 10 HP capacity |
| 57 | Supply and fixing in repair of cable assembly suitable for 10 HP capacity |
| 58 | S&F in repair DOL starter 3 phase of 5 HP to7.5 HP, 415 volts MK 1.5, complete all as specified and directed. |
| 59 | S&F( in repair )chlorinationDozing pump single phase electrically operated 230 volts , 50 HZ ,fuse 1 amp with plastic suction and delivery piping solution tankmaxm output 4.0 LPH complete all as specified and directed. Make -Unichlor of model no- UC-11,Sl no-60365orequivlent of Avon/ |
| 60 | S&F in repair MCCB 160 Amps, 415 volts AC 50Hz, 3 pole, bracking capacity 36 kA ajustable thermal setting,with suitable size of sheet metal enclosure complete all as specified. |
| 61 | S&F in repair MCCB 200 Amps, 415 volts AC 50Hz, 4 pole, bracking capacity 36 kA ajustable thermal setting, with suitable size of sheet metal enclosure complete all as specified. |
| 62 | S&F in replacement 06Sqmm 3 Core submersible cable flat copper conductor all as specified and directed. |
| 63 | Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 64 | M&L for point wiring of One Light/fan point controlled by one switch controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm diaand 3mm thick hylem sheet all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. |
| 65 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board….ditto... |
| 66 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board.….ditto… |
| 67 | Ditto as above but for One bell point controlled by one 5 Amps bell push.….ditto… |
| 68 | M&L for point wiring with(FRLS) flame retardant low smoke PVCinsulated unsheathed cable 2.5 sqmm with multistranded copper conductor,in and including non metallic PVC concealed conduitnot less than 20mm dia with fittings,and 3mm thick hylem sheet including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wallwith top cover and plate including(FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly completefor 3 pin 15 Amps socket independent. Note for item Nos 2 to 7 :- (i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 69 | M&L for point wiring of One Light/fan point controlled by one switchcontrolled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including PVC casing caping all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated, 3mm thick hylem sheet etcand unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. |
| 70 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on same board.….ditto… |
| 71 | Ditto as above but for One 5 Amps socket point controlled by one 5 Amps switch on independent board….ditto... |
| 72 | Ditto as above but for One bell point controlled by one 5 Amps bell push.….ditto… |
| 73 | M&L for point wiring with(FRLS) flame retardant low smoke PVCinsulated unsheathed cable 2.5 sqmm with multistranded copper conductor,in and including PVC casing caping with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of sunken pressed steel GI terminal boxes of not less than 1.6mm wall thickness, concealed in wallwith top cover and plate including(FRLS) flame retardant low smoke PVC insulated copper earth conductor 1.50sqmm connected to common earth and earth dolly completefor 3 pin 15 Amps socket independent. Note for item Nos 8 to 13 :- (i)Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii)Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately. |
| 74 | M&L Switch piano flushtype single pole, one way 5 Amps 230 Volts AC circuit complete all as specified & directed by Engr-in-Charge. |
| 75 | M&L for socket outlet 5 Amps, 5 Pin flush type multipurpose, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 76 | S&F socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 77 | S&F switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 78 | S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 79 | S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed. |
| 80 | S&F fan regulatorelectronic step up type, SP 230 voltcomplete all as specified and as directed. |
| 81 | S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 82 | S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed. |
| 83 | Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed. |
| 84 | S&F 10 watt LED light fitting engineeringplastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS10WLED865SPCWHor equivalent in Bajaj / CG. |
| 85 | S&F 20 watt LED light fitting engineeringplastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Phillips/Havells/Bajaj / CG. |
| 86 | S&F recess mounting LED luminaire of size 2\"x2\"white 34 watt, 230 voltsfor ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. VENUSNEOHE2XR34WLED830PIRSENSOR or equivalent in Bajaj /CG. |
| 87 | Supply and fixing LED Bldg S/ light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make:- Phillips/Havells/Bajaj / CG. |
| 88 | Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connections of6 Sqmm size twin core flat solid conductor Service maincable complete from pole to distribution board main controlling switch complete all as specified and as directed. |
| 89 | S&F in replacement brackets made out of 40/50mm dia medium grade GI pipe 1.50 mtr long bent to shape and size fixed on location using new 2 nos 30x5mm FI clamps made to shape incl nuts, bolts & washers complete all as specified and directed. |
| 90 | Taking down carefullyold and unserviceable sub main wiring of 2/3 runs ormain-wiring of any size ofaluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing caping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed. |
| 91 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 2.50 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 2.5 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 92 | M&L for sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 4.0 sqmm conductor cable, 1 No 4 sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 93 | M&L for sub main wiring with 2 Nos single core PVC insulated -unsheathed 6.0 Sqmm stranded copper conductor cable and 1 No single core PVC insulated-unsheathed 6.0 Sqmm stranded copper conductor cable for earth continuity, drawn in & including suitable PVC casing & capping /PVC pipe with all fittings ISI mark complete all as specified and directed. (length of 2 No 6.0 Sqmm conductor cable, 1 No. 6.0 Sqmm conductor earth continuity cable and accessories shall be measured as one unit length) |
| 94 | Taking down old unserviceable MCCB DBs / MCB DB / Main Switches including MCBs/ MCCBs/ Isolaters, complete all as specified and as directed.Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces. |
| 95 | S&F factory made epoxy powder coated distribution board double doorTP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outscomplete all as specified and directed. |
| 96 | S&F factory made epoxy powder coated distribution board double doorTP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed. |
| 97 | S&F factory made epoxy powder coated distribution board SPN 12 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 98 | S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 99 | S&Ffactory made epoxy powder coated distribution board SPN 4 ways double door with acrylic top cover(IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed. |
| 100 | S&F MCB, SP, 6 to 32 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 101 | S&F MCB, SPN, 32 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 102 | S&F MCB, SPN, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 103 | S&F MCB, TP, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 104 | S&F MCB, TPN, 40 to 63 Amps, \"C\" curve, 10 KA breaking capacity, 240 volts complete all as specified and directed. |
| 105 | S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified. |
| 106 | S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one Triplepole MCB 32 Amp complete all as specified. |
| 107 | Repairing of light point (normal/ flameproof), fan point, socket point 5A/15A, switches sockets, fan regulator, light fixtures any type, lamp any type,MCB DB\"s & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with replacement of any major part but including small length of wires (not more than 50cm) adhesive cable and other connected minor accessories by providing sufficient and skilled manpower. Work shall also include to check & removal of current leakages in Bldgs and any urgent nature of work as and when directed.The scope also include cutting of existing Bakelite sheet to accommodate new elect fittings/fixtures like switches, sockets, fan regulators etc. Note :- (a)The rate quoted by the contractor for Each Job is deemed to be included consisting of minimum 03 complaints in working hours between 0900 AM to 0500 PM in Tech and MES area by engaging one electrician and one helper. (b) The contractor or his representative will take complaint from MES complaint Register through MES job card. (c)The contractor will made separate items register with location and signature of user. (d) The contractor will maintaincomplete details of Job cards (Working/Off working hours) and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor. (f) Risk factor & security pass will be the contractor\"s end. (g) Material will be measured and paid separately in the relevant item here after on supply only. (h)All supply material shall be deposited by contractor in MES store yard and issued in every Job Card as per requirement.(j)The tradesmen should be available at MES area complaint cell (In MES Complex), after completing their daily services as well as during off working hours / Night / Sunday / Holiday. |
| 108 | All as per Item No above but for attending the electrical complaints during off working hours / Night / Sunday / Holiday time for 12 hours. Note :- All as per item No above but the rate quoted by the contractor for \"Each Job\" is deemed to be included 01 complaint in Tech & MES Area |
| 109 | Supply only in replacement switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed. |
| 110 | Supply only in replacement modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 111 | Supply only in replacement modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed. |
| 112 | Supply only in replacement modular socket out let multipurpose 6A -3 pin, SP 1 way 2 module complete all as specified and directed. |
| 113 | Supply only in replacement modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed. |
| 114 | Supply only in replacement modular bell push pole 1 way, 1 module, 6 Amp complete all as specified and directed. |
| 115 | Supply only switch socket combination multipurpose 5 pin 5/15 Amps |
| 116 | Supply only switch socket combination multipurpose 5 pin 5 Amps |
| 117 | Supply only in replacement switch piano, flush type 15/16 amp, single pole, one way 240 volt complete all as specified and directed. |
| 118 | Supply only in replacement socket outlet, 3/5 pin, 5/6 amps flush type complete all as specified and directed. |
| 119 | Supply only in replacement socket outlet, two in one 3 pin, 5/6 & 15/16 amps flush type complete all as specified and directed. |
| 120 | Supply only in replacementbell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed. |
| 121 | Supply only in replacement lamp LED 9/12 watt, 240 volts complete all as specified and directed. |
| 122 | Supply only in replacement capacitor of capacity 2.5 mfdPVC body complete all as specified and directed. Make:- EPCOS/JYOTI/ USHA |
| 123 | Supply only in replacement capacitor of capacity 3.15 mfdPVC body complete all as specified and directed. Make:- EPCOS/ JYOTI/ USHA |
| 124 | Supply only in replacement single run of single core PVC insulated unsheathed cable of size 2.5 Sqmm, FR copper stranded conductor complete all as specified and directed. |
| 125 | Supply only wire flexible 23/0.0076, twin core twisted, PVC insulated copper stranded conductor complete all as specified and directed. |
| 126 | Supply only in replacement complete fan hanging assembly set comprising with rubber reel,MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed. |
| 127 | Supply only in replacement 300mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed. |
| 128 | Supply only in replacement 900mm long down rod 15 mm dia, MS tube light grade, duly finished with powder coating of white colour, including necessary holes and threading etc. complete all as specified and directed. |
| 129 | Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mmsweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department for the following Fans:- Make of winding wire: Atlas/Finolex/ Devi Dayal |
| 130 | All as per item No.abovebut rewinding of motor of exhaust fans of 225/250 mm sweep with 170 gram winding wire. |
| 131 | All as per item No. above but rewinding of motor of exhaust fans of 300/400 mm sweep with 200 gram winding wire. |
| 132 | All as per item No. above but rewinding of motor of air circulating fan of 400 mm sweep with 300 gram winding wire. |
| 133 | Disconnecting, taking down & removing carefully the existing Geyser of any capacity from any position/locations for repairs / fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the geyser, hanging/fixing the repaired geysers in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed.Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.(iii)The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa. |
| 134 | S&F in replacement heating element of 1.5KW any type as per sample ISI marked complete all as specified and directed. |
| 135 | S&F in replacement heating element of 2.0KW any type as per sample ISI marked complete all as specified and directed. |
| 136 | Supply and replace complete Geyser assembly as per exisiting sample including rubber washer and nuts & bolts suitable for water heater capacity 25 Ltrs of any make. |
| 137 | M&L for repairing leakage of inner copper tank of geyser (any make) 25/50 litres capacity by brazing including all necessary denting etc complete all as specified and directed |
| 138 | S&F in replacement thermostat suitable for 25 Ltr geyser complete all as specified and directed. |
| 139 | S&F in replacement thermostat suitable for 50 Ltr geyser complete all as specified and directed. |
| 140 | S&F in replacment PVC pipes of 450mm long best quality, heavy duty for geyser of 15mm dia with brass connecting nuts/couplers complete all as specified and directed. |
| 141 | S&F in replacment indicator lamps red and green colour 230 volts 50 Hz AC supply complete all as specified and directed. |
| 142 | “Supply & and Fixin repair of BLDC ceiling fan PCB Controller Kitalong with speed control Remote 1 N with suitable AAA battery 2N , complete all as specified and directed .Make : HavellsModel : Efficiecia Prime |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail