| 1 | Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil complete all as specified and directed. |
| 3 | Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc n exc 10 sqm on plan and getting out in any type ofsoil complete all as specified and directed. |
| 4 | Returning filling in including spreading levelling watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 5 | Removal of excavated materials n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 6 | M & L PCC 1:4:8 type D-2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate) complete all as specified and directed. |
| 7 | M & L PCC 1:3:6 type C-2 in foundation, filling and mass concrete (using 41 mm graded crushed stone aggregate) complete all as specified and directed. |
| 8 | M & L for 100mm thick cement concrete type D-2, 1:4:8 (40 mm graded aggregate) as in sub bases complete all as specified and as directed. |
| 9 | M & L for sand cushioning under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 10 | M &L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 100 mm thickness M-50 Grade with grey cement and pigments complete all as specified and as directed. |
| 11 | M&L for brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius built in cement mortar 1:6. complete all as specified and directed. |
| 12 | S&F mild steel rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe410-W (Grade E-250) quality A complete all as specified and directed. |
| 13 | S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade Fe410-W (Grade E-250) quality A complete all as specified and directed. |
| 14 | M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe410-W (Grade E-250) quality A complete all as specified and directed. |
| 15 | M&L for mild steel screw bolts (machine made),16-20 mm dia, with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15cm and n exc 22.5cm long |
| 16 | S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws complete all as specified and directed. |
| 17 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with tapping screws as specified. |
| 18 | M&L hardcore (broken stone or boulders) of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rolled / rammed to a true surface complete all as specified and directed. |
| 19 | M & L PCC (1:2:4), type B-1, using 20 mm graded stone aggregate cast in situ in lintels upto 1.5 m span, cills and other similar bands, plinth course, parapets, coping, bed plates and fixing of hold fast and the like including weathering slightly, water through complete all as specified and directed. |
| 20 | M& L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick / concrete/stone, surfaces and finished even and smooth without using extra cement mixed with WPC @ 3% by Wt. of cement (External surfaces) complete all as specified and directed. Note:- WPC shall be measured and paid separately. |
| 21 | Supply only approved integral water proofing compound complete all as specified and directed. |
| 22 | M & L for preparing new surfaces of walls and applying two coats of cement base paint over one coat of white wash complete all as specified and directed. |
| 23 | M&L for applying two coats of synthetic enamel paint over one coat of red oxide exc 10cm width or girth on newly prepared steel surfaces complete all as specified and directed. |
| 24 | Removal of demolished materials, debris etc to a low lying area at a distances n exc 500 Mtr to 1 Km complete all as specified and as directed. |
| 25 | M&L for walling of random rubble, uncoursed well bonded, bedded and solidly hearted, built in CM 1:4 complete all as specified and directed. |
| 26 | M&L for rendering 15 mm thick in CM 1:4 on stone masonry surfaces or surfaces other than fair faces of brickwork and finishing even & smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for extra over stone walling for hammer dressing to face of stones and dressing of face beds and joints, as specified of random rubble walling uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20 mm on granite or trap stone complete all as specified and directed. |
| 28 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 29 | M & L for providing reinforced cement concrete Type B-1 1:2:4 (20mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 30 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 31 | Excavating over areas, n exc 1.5m deep for foundation and getting out in soft / Loose soil complete all as specified and directed. |
| 32 | M&L for stone walling of random rubble stone masonry, brought upto course well bonded, bedded and solidly hearted built in CM (1:4) including providing weep holes, complete all as specified and directed. Note : - Deduction of volume occupied by PCC bond stone shall be made and payment of stone masonry shall be made based on net measurement only. |
| 33 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed face beds and joints of random rubble walling uncoursed or brought upto course surface n exc.40mm in granite or trap stone complete all as specified and directed. |
| 34 | S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 35 | M&L for precast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) set in cement mortar 1:4 as in bond stone walling, complete all as specified and directed. |
| 36 | M&L for stone/boulder filling laid dry, hand packed tightly around weep hole complete all as specified and directed. |
| 37 | M&L for raised pointing to random rubble stone masonry , uncoursed or brought upto courses in cement mortar 1:3 complete all as specified and directed. |
| 38 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming and finishing to required height etc., n exc. 1.5 m high above base complete all as specified and directed. |
| 39 | M&L for forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming and finishing to required height etc. exc 1.50m but n exc. 3.00 m high above base complete all as specified and directed. |
| 40 | M&L for point wiring for one light point/fan point controlled by one switch with cable 1.5 sqmm size PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead, 1100 volts grade including casing and capping (ISI marked) for one light/ fan point including 2nd class hard wood rectangular block open recessed cover with 3mm thick plastic laminated sheet cover including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified. |
| 41 | As per Item No 40 above but point wiring for One socket outlet 5 pins 5 amps controlled by one switch on same board. |
| 42 | As per Item No 40 above but point wiring One socket outlet 5 pins 5 amps controlled by one switch on independent board. |
| 43 | S&F Switch piano type flush 6 Amp Single pole one way (ISI Marked) complete all as specified and directed. |
| 44 | S&F socket outlet multi 5 pins 6 amp, complete all as specified and directed. |
| 45 | S&F switch socket combination 2 in 1, 6A flush type complete all as specified and directed. |
| 46 | Supply and fixing in replacement LED warm lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. |
| 47 | Supply & Fix 35/45 Watts LED luminaries building security light, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium flood light with high power LEDs as light source with IP 66 protection and including driver unit etc complete all as specified and directed. |
| 48 | S&F ceiling rose, PVC/poly carbonate, isolated body three terminal complete all as specified and directed. |
| 49 | S&F sheet metal enclosure for DBs (double door type) when MCBs to be used single pole and neutral 4 way including blanking plate as required with 200 amps rated busbar 240V, fixed sunk/flush to the wall complete all as specified and directed. |
| 50 | S&F MCB \"C\" series, SPN 240V, 32 Amp complete all as specified and directed. |
| 51 | S&F MCB \"C\" series, single pole240V , 6 to 32 Amp complete all as specified and directed. |
| 52 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathed of PVC tape overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable of size 10 Sqmm complete all as specified and directed. |
| 53 | M&L for earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mmthick buried directly in ground (earth pit not less than 2.25mdeep below normal ground level) with top edge of the plate not less than 1.5mbelow normal ground level, connected to galvanized iron wire 4.0 mm diaby means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore and including GI lightgrade water pipe 20mm dia with funneland wire mesh all as shown in electric plate No. 03 of 2009 SSR Pt-I and testing on complete including earth work in any type of soil, PCC 1:2:4 type B-0 as in earth pit and cover 40mm thick reinforced with XPM (weight not less than 4.0Kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, common salt, charcoal and testing oncompletion complete all as specified and directed. |
| 54 | M & L for Point wiring for one 3 Pin 15 Amps socket outlet/sheet metal enclosure independent with 4 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC FRLSH insulated un-sheathed copper conductor single core multi stranded flexible cable (green colour) as earth lead in and including cable 1100 volts grade including casing and capping/PVC conduit (ISI marked) as site requirement including sunk cast iron/pressed steel terminal boxes, junction boxes, other boxes andsheet of suitable sizes for mounting of switches, sockets, fittings etc. covered with suitable plastic laminated sheet or PVC gang box 2 to 8 way as per site requirement including cutting chases to wall making good the disturbed surfaces to match with theexisting specification complete all as specified and directed. |
| 55 | Supply and fixing sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20A, 240V complete with one single pole MCB of any cap from 10 to 20A all as required at site complete all as specified and directed. |
| 56 | Supplying and laying of steel tubes, \"medium grade \", galvanised iron of size 15 mm dia bore, with all fitting(such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or fixed to walls etc. including cutting, threading and screwing etc complete all as specified and directed. |
| 57 | S & F bib taps chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15 mm dia complete all as specified and directed. |
| 58 | S & F Stop valves, fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia complete all as specified and directed. |
| 59 | S & F PVC connections 15mm size with PTMT nuts of length 600 mm suitable for hot water complete all as specified and directed. |
| 60 | Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with an inner sheathings of PVC tape and overall PVC sheathed in services connection suspended by insulating hangers not more than one meter apart including 4mm dia GI suspension wire one twin core cable plate or circular of size 6 sqmm complete all as specified and directed. |
| 61 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed. |
| 62 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed. |
| 63 | Supply, installation, testing and commissioning industrial RO + UV + PHE + softener water purifier system of capacity 1000 LPH consisting of three numbers fibre reinforced polymer vessel with treatment media like FBM, AFM, MGS, ACM, CPM, softener media etc along with back wash system with multiport valves, strainer, feed water pump, high pressure pump, RO element, ultra violet system with electric control panel and internal and internal CPVC pipe fitting, gate valves, non return valves, inlet and outlet connections fitted on wall furnished and painted MS frame including suitable size of PCC foundation complete in all respect with anti scaling dosing system, PH enhancer dosing system and containers complete all as specified and directed. |
| 64 | M&L for stainless steel water storage tank with double wall insulated and steel of grade SS316 & SS304 of capacity 1000 Ltrs and diameter 1600 mm conf. complete all as specified and directed. |
| 65 | M & L rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed including Staging for suitable size with MS frame/PCC foundationas per height manufacturer specification in position all as specified in SSR Part I for water storage PVC tank triple layer of capacity 2000 ltrs complete all as specified and directed. |
| 66 | M&L for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 67 | Supply and fixing of voltage stabilizer for automatic operation three phase naturally oil cooled indoor type & designed for input variation between 240 V to 480 Volt with output voltage stabilized at 415 Volts with accuracy + 2.5 % and speed of correction 8 volts per second and of capacity of 15 KVA complete all as specified and directed. |
| 68 | Supply and fixing of Busbar chamber wall mounted type of current carrying capacity 63 Amp, 4 Pole 3 Phase 4 way (as required as per site requirement) complete all as specified and directed. |
| 69 | Supply and Laying, jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor ,1100 volts grade ,cross section area 16 Sqmm 4 core complete laid in trenches, ducts or fix to pipe, on walls, poles complete all as specified and directed. |